Thermal-Magnetic Circuit Breaker 2210-T2.. Description One, two and three pole thermal-magnetic circuit breakers with trip-free mechanism and toggle actuation (S-type TM CBE to EN 60934/IEC 934). Featuring a combi-foot design for both symmetric and asymmetric rail mounting. Available with auxiliary contact (1 x N/O or 1 x N/C) for status signalling. Two and three pole models are internally linked to ensure that both/all poles trip in the event of an overload on one pole, even if the actuator is held in the ON position. This CBE can be supplied in current ratings up to 32 A with a choice of characteristic curves. All screw terminals are recessed for safety. Approved to CBE standard EN 60934 (IEC 60934). 1 Typical applications 2210-T2.. 2-pole Process control equipment, robotics, machine tool control, communications systems, instrumentation. Features Your benefits l Comprehensive approvals allow global use l Space and weight savings of at least 50 % compared to l Current rating range from 0.1 A to 32 A conventional MCBs l Very small width of only 12.5 mm including auxiliary contacts l Reduced assembly times thanks to integral auxiliary contacts l High vibration resistance to DNV GL Class B for mounting with l Optimum equipment protection through fine grading of combustion engines, pumps, compressors current ratings l Compliant with the relevant requirements of the railway standards DIN EN 50155, DIN EN 61373 and EN 45545 (detailed information upon request) Preferred types for more details on all configurations please see order numbering code Preferred types are E-T-A products most frequently used by E-T-A volumes. Our preferred types are supplied at shorter lead times than customers. We manufacture E-T-A preferred types in particularly high non-standard versions. Preferred types Standard current ratings (A) 1-pole 0.5 1 2 3 4 5 6 8 10 16 20 x x x x x x x x x x x 2210-T210-K0M1-H121- 2-pole 0.5 1 2 3 4 5 6 8 10 16 20 x x x x x x 2210-T220-K0M1-H221- Approvals Data sheet For access to the latest documents please follow:www.e-t-a.de/en053 Compliances 2011 www.e-t-a.de 1Thermal-Magnetic Circuit Breaker 2210-T2.. Thermal-Magnetic Circuit Breaker 2210-T2.. Standard current ratings and typical internal resistance values Technical data For further details please see: www.e-t-a.de/ti e Current rating (A) Internal resistance () Voltage rating AC 250 V 3 AC 433 V (50/60 Hz) DC 65 V F1 F2 M1 T1 (UL: AC 277/480 V DC 65 V) fast acting fast acting standard for delayed low Current rating range 0.1...32 A for curves M1, T1 for DC only delay for AC+DC resistance 0.1...16 A for curves F1, F2 AC + DC for AC only Auxiliary circuit 1 A, AC 240 V / DC 65 V, resistive 0.1 162 162 92 81 (min. 10 V / 10 mA) 0.2 39.3 39.3 26.1 24.2 Typical life 3 AC 433 V AC 250 V: 0.1...25 A 0.3 17.5 17.5 11.6 10.4 10,000 operations at 1 x I , inductive N 0.4 9.2 9.2 6.6 6.0 DC 65 V: 0.1...32 A 1 10,000 operations at 1 x I , inductive N 0.5 6.8 6.8 4.1 3.9 3 AC 433 V AC 250 V: 32 A 0.6 4.2 4.2 3 2.7 6,000 operations at 1 x I , resistive N Ambient temperature -30...+60 C (-22...+140 F) T 60 0.8 2.8 2.8 1.65 1.53 Insulation co-ordination rated impulse pollution 1 1.6 1.6 1.10 0.98 (IEC 60664 and 60664 A) withstand voltage degree 1.5 0.78 0,78 0.47 0.42 2.5 kV 2 reinforced insulation in operating area 2 0.42 0,42 0.28 0.24 Dielectric strength 2.5 0.26 0.26 0.183 0.17 (IEC 60664 and 60664A) test voltage 3 0.18 0.18 0.124 0.12 operating area AC 3,000 V main/aux. circuit AC 3,000 V 4 0.12 0.12 0.077 0.073 pole/pole AC 1,500 V 5 0.092 0.092 0.063 0.055 Insulation resistance > 100 M (DC 500 V) 6 0.054 0.054 0.045 0.039 Interrupting capacity I 0.1...5 A 400 A cn 6...32 A 800 A 8 0.025 0.025 0.02 0.02 curves F1, F2, M1, T1: 0.1...16 A 2,500 A (at DC 32 V) 10 0.022 0.02 0.02 0.02 Interrupting capacity (UL 1077) 12 0.02 0.02 0.02 0.02 I 0.1...16 A 20...32 A N 16 0.02 0.02 0.02 0.02 AC 277 V 1-pole 5,000 A 2,000 A AC 277/480 V 2-/3-pole 5,000 A 2,000 A 20 - - 0.02 0.02 DC 65 V 2,000 A 2,000 A 25 - - 0.02 0.02 Degree of protection operating area IP30 32 - - 0.02 0.02 (IEC 60529/DIN 40050) terminal area IP20 Vibration curves F1, F2: 3 g (57-500 Hz), 0.23 mm (10-57 Hz) curves M1, T1: 5 g (57-500 Hz), 0.38 mm (10-57 Hz) Approvals to IEC 60068-2-6, test Fc 10 frequency cycles/axis Authority Standard Rated voltage Current ratings Shock curves F1, F2: 25 g (11 ms), directions 1, 2, 3, 4, 5 10 g (11 ms), direction 6 VDE IEC/EN 3 AC 433 V 0.1 A32 A curves M1, T1: 25 g (11 ms), directions 1, 2, 3, 4, 5 AC 250 V 0.1 A32 A 60934 20 g (11 ms), direction 6 DC 65 V 0.1 A32 A to IEC 60068-2-27, test Ea UL UL 1077 AC 277/480 V 0.1 A32 A Corrosion 96 hours at 5 % salt mist AC 277 V 0.1 A32 A to IEC 60068-2-11, test Ka DC 65 V 0.1 A32 A Humidity 240 hours at 95 % RH CSA C22.2 No AC 277/480 V 0.1 A32 A to IEC 60068-2-78, test Cab 235 AC 277 V 0.1 A32 A Mass approx. 60 g per pole DC 65 V 0.1 A32 A CQC GB 17701 AC 250/433 V 0.1 A32 A 0.1 A32 A AC 250 V 0.1 A32 A DC 65 V DNV GL IEC 60934, 0.1 A32 A 3 AC 433 V 0.1 A32 A DNVGL- AC 250 V 0.1 A32 A DC 65 V CG 0339 KTL KC60934 0.1 A...16 A AC 250 V, 1-pole AC 433 V, 2-pole 0.1 A...16 A 2 www.e-t-a.de 2011