ETA-USA The Power Professionals 200W DTE-SX-F-W-C2 Features High Reliability 100% BURN-IN Tested 100% Hi-Pot tested Safety Approvals, EMC compliance 40mm cooling fan AC input IEC 320-C14 Inlet Two year warranty Meet CEC & Energy Star level V requirements Green functions+ No load power consumption <.3W TUV Rheinland DTE200- DTE200- DTE200- DTE200- DTE200- DTE200- DTE200- MODEL/CHANNEL Unit 12SX-F-W 16SX-F-W 19SX-F-W 20SX-F-W 24SX-F-W 36SX-F-W 48SX-F-W Norminal Voltage OUTPUT V 12 16 19 20 24 36 48 Nominal Current A 16.66 12.5 10.53 10 8.33 5.56 4.17 Ripple & Noise Max % 240 300 300 300 300 300 300 W Power 200 Output Power Reg. VAC 5% VAC Riseup time >16ms typical at full load 115VA V INPUT Input Voltage Range 90~264VAC Inrush Current(rms): % 150A(max) at 230VAC cold start Efciency % >85% full load, 115VAC Current 3A 115Vac, 60Hz Hz Frequency: Hz 47~63Hz Power Factor - > 0.9(115VAC100% Load) 0 to +50C Environmental Operating Temperature C Storage Temperature C -10 to +70C Specification VAC Environmental MTBF demonstrated >140,000 hours at full load and 25 C ambient temperature Humidity Agencies - 20%~90% non-condensing Temperature coefficient C 0.05% /C Primary-secondary: 4242VDC for 4sec Withstanding voltage - Primary-frame ground: 2121VDC for 4sec Primary-secondary: 20M min. 500VDC Insulation resistance - Primary-frame ground: 20M min. 500VDC CSA 22.2-No.60950-1 TUV EN60950-1 CB IEC 60950-1 Safety Standards - CISPR 22 Class B FCC Class B,EN55022 Class B CE - Auto Recover once short circuit removed Short circuit protection Protection - Auto Recover. Overload range from 110%~160% max load. Over Load Protection Overvoltage range from 13.2~16VDC, latch off before reaching - Over Voltage Protection limit. Manual power reset necessary. Dimension/*Weight mm/g L188.5 x W104.5 x H60mm ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 ETA-USA The Power Professionals Dimension Diagram (mm) 200W ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037