ETA-USA The Power Professionals MDA-SX-W-II 24W FEATURES: High Reliability 100% BURN-IN Tested 100% Hi-Pot tested Safety Approvals, EMC compliance Interchangable AC clips Meets CEC, ERP, EISA, and Energy Star Level V requirements No load power consumption <300mW Short circuit, over load, over voltage protection BAUART GEPRFT TUV Rheinland MDA24- MDA24- MDA24- MDA24- MDA24- MDA24- MODEL/CHANNEL Unit 05SX-W-II 09SX-W-II 12SX-W-II 16SX-W-II 18SX-W-II 24SX-W-II OUTPUT Output Voltage Vdc 5 5 12 16 18 24 Output Current A 3 2.66 2 1.5 1.34 1 Ripple and Noise(max.) *3 mV 50 50 120 160 180 240 MDA24- MDA24- MODEL/CHANNEL Unit 36SX-W-II 48SX-W-II Output Voltage Vdc OUTPUT 36 48 Output Current A 0.67 0.5 Ripple and Noise(max.) *3 mV 360 480 Hold Up Time mS >10 mS typical Voltage Adjustments % 5% of Rated Output Voltage(at no load within the input range) Voltage Regulations - +5%/-3% INPUT Input Voltage Vac 90~264VAC Input Frequency Hz 0.7A max. 90VAC 47~63Hz 1% Efficiency % 0.35A max. 264VAC Protection Over Current Protection - Auto-recover Over Voltage Protection - Latch, AC recycle Short Circuit Protection - Auto-recover Environmental Safety Standard - UL 60601-1 CSA-C22.2 No.601.1-M90 NEMKO EN60601-1 CB IEC 60601-1 Agencies EMC Standard - FCC Part 18Class B EN55011 Class B EN 60601-1-2 Class B CE Environment Operating Temperature - -20C to +40C Storage Temperature - -20C to +85C Humidity % 20~90% MTBF demonstrated - >150,000 hours at full load and 25C ambient temperature Dimension Size(WxHxD) / Weight mm/g L80.0mmW50.0H35.0mm ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 ETA-USA The Power Professionals 24W Dimension Diagram (mm) ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037