ETA-USA The Power Professionals NVD-SC/NVD-SD 100W FEATURES Light weight, compact size High efficiency, high reliability Input under voltage protection Over current, over voltage, thermal protection UL, cUL, CE Isolated Power Supply C NVD3.3- NVD05- NVD12- NVD15- NVD24- MODEL/CHANNEL Unit SC24-U1 SC24-U1 SC24-U1 SC24-U1 SC24-U1 OUTPUT Output Current 24VDC Vdc 3.3 5 12 15 24 (Single) Output Current A 20 20 9 7 5 NVD3.3- NVD05- NVD12- NVD15- NVD24- MODEL/CHANNEL Unit SC48-U1 SC48-U1 SC48-U1 SC48-U1 SC48-U1 OUTPUT Output Current 48VDC Vdc 3.3 5 12 15 24 (Single) Output Current A 20 20 9 7 5 NVD3.3- NVD05- NVD12- NVD15- NVD24- MODEL/CHANNEL Unit SD-U1 SD-U1 SD-U1 SD-U1 SD-U1 Output Current 110VDC Vdc 3.3 5 12 15 24 OUTPUT (Single) Output Current A 20 20 9 7 5 NVD3.3- NVD05- NVD12- NVD15- NVD24- MODEL/CHANNEL Unit SC12-U1 SC12-U1 SC12-U1 SC12-U1 SC12-U1 Output Voltage Vdc 3.3 5 12 15 24 OUTPUT (Single) Output Current 12VDC A 20 15 6.8 5.4 3.4 Line Regulation mV 26 40 96 120 190 Load Regulation mVp 30 45 108 135 216 Ripple and Noise mVp 150 150 220 250 350 Voltage Adjustment Range - 10% of Rated Output Voltage Rise Time - 200mS(500mS for NVDxSD Series)(maximum) at 25C and rated input/output Temp. Coefficient C 0.03%/C Drift mV 32 40 75 90 135 mV 150 200 360 450 720 Dynamic Load Regulation Recovery Time mS 20 NVD3.3- NVD05- NVD12- NVD15- NVD24- MODEL/CHANNEL Unit SC12-U1 SC12-U1 SC12-U1 SC12-U1 SC12-U1 Input Voltage 12V Vdc 12 INPUT Input Voltage Range Vdc 9.6-16 Input Current A 6.18 8.33 8.24 8.33 8.26 Efficiency % 89 90 91 90 92 Ref. MTB H 495,000 560,000 576,000 549,000 Switching Frequency kHz 125fix. ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037 ETA-USA The Power Professionals NVD3.3- NVD05- NVD12- NVD15- NVD24- MODEL/CHANNEL Unit SC24-U1 SC24-U1 SC24-U1 SC24-U1 SC24-U1 Input Voltage 24V Vdc 24 Input Voltage Range Vdc 19~32 Input C urrent A 3.3 4.53 4.89 4.75 5.4 Efficiency % 90 92 92 92 92 Ref. MTBF H 496,000 555,000 571,000 556,000 Switching Frequency kHz 125fix. NVD3.3- NVD05- NVD12- NVD15- NVD24- MODEL/CHANNEL Unit SC48-U1 SC48-U1 SC48-U1 SC48-U1 SC48-U1 Input Voltage 48V Vdc 48 Input Voltage Range Vdc 38V~63 Input Current A 1.65 2.24 2.39 2.33 2.64 Efficiency % 91 93 94 94 94 Ref. MTBF H 554,000 569,000 562,000 Switching Frequency kHz 125fix. NVD3.3- NVD05- NVD12- NVD15- NVD24- MODEL/CHANNEL Unit SD-U1 SD-U1 SD-U1 SD-U1 SD-U1 Input Voltage 110V Vdc 110 Input Voltage Range Vdc 85~140 Input Current A 0.725 0.977 1.055 1.02 1.16 Efficiency % 91 93 93 93 94 Ref. MTBF H 480,000 550,000 Switching Frequency kHz 91fix. 125fix. MODEL/CHANNEL Unit Environment Operating Temperature -10 to 71C Operating Humidity % 20-80%/RH (non-condensing) Storage Temperature -20 to +85C Withstand Voltage Primary-Secondary AC2,000V at 10mA for 1 minute/Primary-Frame Ground % Primary-Secondary AC2,000V at 10mA for 1 minute/Secondary-Frame Ground AC1,000V at 10mA for 1 minute Derating - 3.5%/C (50C to 71C) Storage Humidity - 20 to 90%/RH Isolation Resistance - Primary-Secondary-Frame Ground 50M(minimum) by DC500V insulation tester Shock - 196m/s 2 Cooling - Convection 5-10Hz: 10mm double amplitude,10-55Hz: 19.6m/s 2, 20minutes Vibration - period for 30 minutes each along X, Y, Z axes(non-operating) Safety - UL60950, C-UL(CSA60950), CE Protection Over Current Protection A Current Limiting Over Voltage Protection - Latch Type (output shutdown) Input Voltage Protection - Output shutdown when input voltage remains under the input range for 3 seconds (typ.) Thermal Protection - Output shutdown when input voltage remains under the input range for 3 seconds (typ.) Size(WxLxH) / Weight mm/g 65Wx101Lx34H mm(Not include output terminal)/250g Dimension * Input fuse is installed in unit * Common mode filter is installed at the input side of unit ETA-USA 16170 Vineyard Blvd. Suite 180 Morgan Hill, CA 95037