D D D D E E R R E E 10 Series - Light dependent relays 12 - 16 A Features 10.32 10.41 Relays for automatic control of lighting according to the ambient light level Integral light sensor For pole or wall mounting 10.32 - 2 NO 16A output contacts 10.41 - 1 NO 16A output contact Double pole Live and Neutral switching possible with the 10.32 Sensitivity adjustment from 1 to 80 lux Double pole switching - 2 NO 16A Single pole switching - 1 NO 16A Cadmium free contact material for Live and Neutral switching for Live switching Cadmium free light sensor (IC photo diode) Electronic circuit - transformer isolated Italian Patent light feedback compensation innovative principle Compatible with slow starting gas discharge lamps (up to 10 minutes) For the first 3 working cycles the delay time (On and Off) is reduced to zero in order to aid installation Available for supply 230 and 120 V AC (50/60 Hz) Contact specification Contact configuration 2 NO (DPST-NO) 1 NO (SPST-NO) Rated current/Maximum peak current A 16/30 (120 A - 5 ms) 16/30 (120 A - 5 ms) Rated voltage/Maximum switching voltage V AC 120/ 230/ 120/ 230/ Rated load AC1 VA 1,900 3,700 1,900 3,700 Rated load AC15 VA 400 750 400 750 Rated current AC5a A 5 5 Nominal lamp rating: incandescent W 1,200 2,300 1,000 2,000 compensated fluorescent W 450 850 400 750 uncompensated fluorescent W 500 1,000 500 1,000 halogen W 1,200 2,300 1,000 2,000 Minimum switching load mW (V/mA) 1,000 (10/10) 1,000 (10/10) Standard contact material AgSnO AgSnO 2 2 Supply specification Nominal voltage (U ) V AC (50/60 Hz) 120 230 120 230 N V DC Rated power AC/DC VA (50 Hz)/W 2/ 2/ Operating range AC (50 Hz) (0.81.1)U (0.81.1)U N N DC Technical data 3 3 Electrical life at rated load in AC1 cycles 100 10 100 10 Threshold setting lx 180 180 Preset threshold lx 10 10 Delay time: switching ON/OFF s 15/30 15/30 Ambient temperature range C 30+70 30+70 Protection category IP 54 IP 54 Approvals (according to type) 1 E E S S T T COMMUNITY COMMUNITY I I S S I I G G G G E E N N R R D D D D E E R R E E 10 Series - Light dependent relays 12 - 16 A Features 10.42 10.51 10.61 Relays for automatic control of lighting according to the ambient light level Integral light sensor For pole or wall mounting 10.42 - Two independent 16A outputs with individual lux setting 10.51 - Miniature single 12A NO output 10.61 - Mounting on street light body Sensitivity adjustment from 1 to 80 lux Two independent outputs - Single pole switching - 1 NO 12A Single pole switching - Fixed sensivity 10 lux ( 20%) - (10.61 type) Miniature size 2 NO 16A 1 NO 16 A Cadmium free contact material Cadmium free light sensor (IC photo diode) Electronic circuit - transformer isolated (10.42 type) Italian Patent light feedback compensation innovative principle (10.51 type) For the first 3 working cycles the delay time (On and Off) is reduced to zero in order to aid installation Available for supply 230 and 120 V AC (50/60 Hz) Prewired with silicone wire, 500 mm length (10.61 type) Contact specification Contact configuration 2 NO (DPST-NO) 1 NO (SPST-NO) 1 NO (SPST-NO) Rated current/Maximum peak current A 16/30 (120 A 5 ms) 12/25 (80 A 5 ms) 16/30 (120 A 5 ms) Rated voltage/Maximum switching voltage V AC 120/ 230/ 120/ 230/ 230/ Rated load AC1 VA 1,900 3,700 1,400 2,760 3,700 Rated load AC15 VA 400 750 300 600 750 Rated current AC5a A 5 5 Nominal lamp rating: incandescent W 1,000 2,000 600 1,200 2,000 compensated fluorescent W 400 750 200 400 750 uncompensated fluorescent W 500 1,000 300 600 1,000 halogen W 1,000 2,000 600 1,200 2,000 Minimum switching load mW (V/mA) 1,000 (10/10) 1,000 (10/10) 1,000 (10/10) Standard contact material AgSnO AgSnO AgSnO 2 2 2 Supply specification Nominal voltage (U ) V AC (50/60 Hz) 120 230 120 230 230 N V DC Rated power AC/DC VA (50 Hz)/W 2/ 1.5/ 2.5/ Operating range AC (50 Hz) (0.81.1)U (0.81.1)U (0.81.1)U N N N DC Technical data 3 3 3 Electrical life at rated load in AC1 cycles 100 10 100 10 100 10 Threshold setting lx 180 180 10 Preset threshold lx 10 10 10 Delay time: switching ON/OFF s 15/30 15/30 15/30 Ambient temperature range C 30+70 30+70 30+70 Protection category IP 54 IP 54 IP 54 Approvals (according to type) 2 E E S S T T COMMUNITY COMMUNITY I I S S I I G G G G E E N N R R