12 SERIES 12 Time switches 16A SERIES Mechanical time switches 12.01 12.11 12.31 - Daily time setting* - Weekly time setting** Type 12.01 - Daily - 1 CO 16A - 35.8mm wide - 35mm rail mount Type 12.11 - Daily - 1 NO 16A Mechanical daily time switch Mechanical daily time switch Mechanical daily or weekly - 17.5mm wide 1 CO 16A 1 NO 16A 1 CO 16A - 35mm rail mount 35mm rail (EN60715) mount 35mm rail (EN60715) mount Front panel mounting Type 12.31-0000 - Daily - 1 CO 16A - 72x72 mm - Front panel mount Type 12.31-0007 - Weekly - 1 CO 16A - 72x72 mm - Front panel mount Minimum time interval setting: 1h (12.31-0007) 30min (12.01) 15min (12.11 - 12.31-0000) * Same program every day ** Diff erent program possible for each of the 7days of the week For outline drawing see page 11 Contact specification Contact configuration 1 CO (SPDT) 1 NO (SPST-NO) 1 CO (SPDT) Rated current/Maximum peak current A 16/ 16/30 16/ Rated voltage/Maximum switching voltage VAC 250/ 250/ 250/ Rated load AC1 VA 4000 4000 4000 Rated load AC15 (230VAC) VA 750 420 420 I Nominal lamp rating: incandescent (230V) W 2000 (NO contact) 2000 2000 compensated fluorescent (230V) W 750 (NO contact) 750 750 uncompensated fluorescent (230V) W 1000 (NO contact) 1000 1000 halogen (230V) W 2000 (NO contact) 2000 2000 Minimum switching load mW (V/mA) 1000 (10/10) 1000 (10/10) 1000 (10/10) Standard contact material AgSnO AgSnO AgCdO 2 2 Supply specification Nominal voltage (U ) V AC (50/60Hz) 230 230 120 - 230 N VDC Rated power AC/DC VA (50Hz)/W 2/ 2/ 2/ Operating range AC (50Hz) (0.851.1)U (0.851.1)U (0.851.1)U N N N DC Technical data 3 3 3 Electrical life at rated load in AC1 cycles 5010 5010 5010 Type of time switch daily daily daily weekly Switching intervals /day 48 96 96 24 (168/week) Minimum switching interval min 30 15 15 60 Accuracy s/day 1.5 1.5 1.5 Ambient temperature range C 5+50 5+50 10+50 Protection category IP 20 IP 20 IP 20 Approvals (according to type) 1 III-2016, www.findernet.comP O R U E N A E 12 SERIES 12 Time/Astro-Switch 16A SERIES Type 12.51 12.51 12.81 Digital (analogue-style) time switch, daily/weekly programming - Can be programmed in Classic mode via the joystick, or Smart mode via smartphones with NFC communication - Minimum time interval setting - 30minutes - Easily configurable for daily or weekly programming Type 12.81 Digital Astro-switch - Can be programmed in Classic mode via the joystick, or Smart mode via smartphones with NFC communication Digital time switch Digital Astro-switch - Astro program: calculation of sunrise and 1 CO 16A 1 CO 16A sunset times through date, time and location coordinates - Option for Astro ON period override, by timeswitch - Location coordinates easily settable for most European countries through post codes - Offset function: allows programming of switching times offset from the astronomic time (by up to 90min, in 10min steps) Summer/Winter European, Australian, Brazilian time 1 CO 16A output contact LCD status indication, set-up and programming Lock with a 4-digit PIN Back-light display Internal battery for set-up and programming without supply, easily replaceable from the front Protective separation between supply and contacts 35mm wide 35mm rail (EN60715) mount Cadmium free contact material For outline drawing see page 11 Contact specification Contact configuration 1 CO (SPDT) 1 CO (SPDT) Rated current/Maximum peak current A 16/30 (120A - 5ms) 16/30 (120A - 5ms) Rated voltage/Maximum switching voltage VAC 250/400 250/400 Rated load AC1 VA 4000 4000 Rated load AC15 (230VAC) VA 750 750 Nominal lamp rating: 230V incandescent/halogen W 2000 2000 fluorescent tubes with electronic ballast W 1000 1000 fluorescent tubes with I electromechanical ballast W 750 750 CFL W 400 400 230V LED W 400 400 LV halogen or LED with electronic ballast W 400 400 LV halogen or LED with electromechanical ballast W 800 800 Minimum switching load mW (V/mA) 1000 (10/10) 1000 (10/10) Standard contact material AgSnO AgSnO 2 2 Supply specification Nominal voltage (U ) VAC (50/60Hz) 110230 110230 N VDC 110230 110230 Rated power AC/DC VA (50Hz)/W 2.8/0.9 2.8/0.9 Operating range AC (50Hz) (0.81.15)U (0.81.15)U N N DC (0.81.15)U (0.81.15)U N N Technical data 3 3 Electrical life at rated load in AC1 cycles 10010 10010 Switching intervals 48 Minimum switching interval min 30 Accuracy s/day 1 1 20+50 (see page 7, 20+50 (see page 7, Ambient temperature range C diagram L12) diagram L12) Protection category IP 20 IP 20 Approvals (according to type) 2 P PA TENT O R U E III-2016, www.findernet.com N A E