Ericsson Internal Ericsson Internal E TABLE OF CONTEPRODUCT SPECIFICATION NTS 1 (2)1 (3) PrPreparepareedd ( (aallsso so subjubjecectt r reesponsisponsibbllee i iff othotheerr)) NNoo SEC/S Kevin EZHIXZH 1/1301Zhou 00152-E-BMR N/LZ636 T1463Uen 94 Technical Speci cation ApprApprovoved Ced Checked hecked DDate ate RReevv RRefereferencence e EN/LZT 146 394 R4A Sep 2008 PKB 4000 series SEC/S Kevin SEC/D (Julia You) Zhou MICJOHN 20082008-4-9-10 B -24 D Ericsson Power Modules AB DC/DC converters, Input 36-75 V, Output 30 A/90 W Key Features Industry standard Eighth-brick 58.4 x 22.7 x 8.10 mm (2.30 x 0.894 x 0.32 in.) Low profile, max 8.10 mm (0.32 in.) High efficiency, typ. 90.6 % at half load 2250 Vdc input to output isolation Meets isolation requirements equivalent to basic insulation according to IEC/EN/UL 60950 More than 1.6 million hours predicted MTBF at +40C ambient temperature General Characteristics Suited for narrow board pitch applications (15 mm/0.6 in) Output over voltage protection Input under voltage shutdown Over temperature protection Safety Approvals Design for Environment Output short-circuit protection Remote sense Remote control Output voltage adjust function Meets requirements in high- Highly automated manufacturing ensures quality temperature lead-free soldering ISO 9001/14001 certified supplier processes. Contents General Information .............................................................2 Safety Specification .............................................................3 Absolute Maximum Ratings .............................................................4 Product Program Ordering No. 1.2V, 30A / 36W Electrical Specification PKB 4318 PIOBNB............................... 5 1.5V, 30A / 45W Electrical Specification PKB 4418 PIOANB ............................... 8 1.8V, 25A / 45W Electrical Specification PKB 4418 PINB .................................. 11 2.5V, 25A / 62.5W Electrical Specification PKB 4619 PINB .................................. 14 3.3V, 20A / 66W Electrical Specification PKB 4610 PINB .................................. 17 3.3V, 25A / 82.5W Electrical Specification PKB 4810 PINB .................................. 20 5.0V, 15A / 75W Electrical Specification PKB 4711 PINB .................................. 23 12V, 6A / 72W Electrical Specification PKB 4713 PINB .................................. 26 12V, 7.5A / 90W Electrical Specification PKB 4913 PINB .................................. 29 15V, 5A / 75W Electrical Specification PKB 4715 PINB .................................. 32 EMC Specification ........................................................... 35 Operating Information ...........................................................36 Thermal Consideration ...........................................................37 Connections ...........................................................38 Mechanical Information ...........................................................39 Soldering Information ...........................................................41 Delivery Information ...........................................................42 Product Qualification Specification ...........................................................43 Ericsson Internal E PRODUCT SPECIFICATION 2 (3) Prepared (also subject responsible if other) No. EZHIXZH 1/1301-BMR 636 Uen 2 Technical Speci cation Approved Checked Date Rev Reference EN/LZT 146 394 R4A Sep 2008 PKB 4000 series SEC/D (Julia You) MICJOHN 2008-4-10 B Ericsson Power Modules AB DC/DC converters, Input 36-75 V, Output 30 A/90 W Compatibility with RoHS requirements General Information The products are compatible with the relevant clauses and requirements of the RoHS directive 2002/95/EC and have a Ordering Information maximum concentration value of 0.1% by weight in See Contents for individual product ordering numbers. homogeneous materials for lead, mercury, hexavalent chromium, PBB and PBDE and of 0.01% by weight in Option Suffix Ordering No. homogeneous materials for cadmium. Isolated Surface mount SI PKB 4711 SINB Positive Remote Control Logic P PKB 4711 PIPNB Increased stand-off height M PKB 4711 PINBM Exemptions in the RoHS directive utilized in Ericsson Lead length 3.69 mm (0.145 in) LA PKB 4711 PINBLA Power Modules products include: Lead length 4.57 mm (0.180 in) LB PKB 4711 PINBLB - Lead in high melting temperature type solder (used to Note : As an example a positive logic, increased standoff, short pin product solder the die in semiconductor packages) would be PKB 4711 PIPNBMLA. - Lead in glass of electronics components and in electronic ceramic parts (e.g. fill material in chip Reliability resistors) The Mean Time Between Failure (MTBF) is calculated at full - Lead as an alloying element in copper alloy containing output power and an operating ambient temperature (T ) of A up to 4% lead by weight (used in connection pins +40C, which is a typical condition in Information and made of Brass) Communication Technology (ICT) equipment. Different methods could be used to calculate the predicted MTBF Quality Statement and failure rate which may give different results. Ericsson Power Modules currently uses Telcordia SR332. The products are designed and manufactured in an industrial environment where quality systems and methods Predicted MTBF for the series is: like ISO 9000, 6 (sigma), and SPC are intensively in use to - 1.6 million hours according to Telcordia SR332, issue boost the continuous improvements strategy. Infant 1, Black box technique. mortality or early failures in the products are screened out and they are subjected to an ATE-based final test. The Ericsson failure rate data system is based on field Conservative design rules, design reviews and product tracking data. The data corresponds to actual failure rates qualifications, plus the high competence of an engaged of components used in ICT equipment in temperature work force, contribute to the high quality of our products. controlled environments (T = -5...+65C). A Telcordia SR332 is a commonly used standard method Warranty intended for reliability calculations in ICT equipment. The Warranty period and conditions are defined in Ericsson parts count procedure used in this method was originally Power Modules General Terms and Conditions of Sale. modelled on the methods from MIL-HDBK-217F, Reliability Predictions of Electronic Equipment. It assumes that no Limitation of Liability reliability data is available on the actual units and devices for which the predictions are to be made, i.e. all predictions Ericsson Power Modules does not make any other are based on generic reliability parameters. warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a persons health or life).