Ti125, Ti110, Ti105 Industrial-Commercial and the Ti100 General Technical Data Use Thermal Imagers The lightest, most rugged and easiestto-use professional thermal imagers around. A Fluke thermal imager can save you time and money by finding potential problems before they become costly failures. With the innovative features and functionality in the Fluke Ti125, Ti110, Ti105 and Ti100 imagers, you can perform infrared inspections faster and more efficiently and thoroughly document problem areas for additional follow-up. Ti125 Key features Ti100 Exclusive IR-OptiFlex focus systemensures that images are in good focus from 1.2 meters (4 feet) and beyond for Made in the U.S.A. optimum image clarity and scanning convenience. For shorter of U.S. and non U.S. distances change to manual mode with the touch of a finger parts (Ti110 and Ti125). Always have references handyIR-PhotoNotes annotation systemQuickly identify and keep track of inspection locations by adding digital images of important information and Ti110 Ti105 surrounding areas (Ti110 and Ti125). Find problems faster and easier with Fluke IR-Fusion technology (Ti125, Ti110, Ti105). Accurately identify potential issues Industrial, mechanical, electromechanical and general by combining digital and IR images. building maintenance. Get further clarification with AutoBlend modethe blending of a digital and partially transparent IR image into a single Process, refractory insulation, tank information-filled image (Ti125 only). and vessel levels, steam systems Multi-mode video recordingfocus-free video in visible light and traps, pipes and valves, etc. and infrared with full IR-Fusion. (Ti110 and Ti125 only). Easily communicate the location of problems with the Electronic Electrical, unbalanced loads, 8-Point Cardinal Compass (Ti110 and Ti125 only). overloaded systems, wiring problems or component failure, etc. Spend less time finding problems and more time solving them with the innovative, rugged and easy to use Ti125, Ti110, Ti105 Industrial-Commercial and Ti100 General Use Thermal Imagers. Patented Fluke IR-Fusion Technology IR-OptiFlex focus system Enjoy the industrys only point-and-shoot IR-Fusion Scan for issues significantly faster than before camera. Fluke patented technology provides the user with Flukes revolutionary, ultra-rugged focus system. with both a digital and an infrared image in one to The IR-OptiFlex focus system gives you optimum precisely document problem areas. focus by combining focus-free, ease-of-use with the flexibility of manual focus on the same camera.Detailed specifications Ti125 Ti110 Ti105 Ti100 Industrial-Commercial General use IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer Spectral band 7.5 m to 14 m (long wave) Capture or refresh rate 9 Hz or 30 Hz versions 9 Hz NETD (Thermal sensitivity) 0.10 C at 30 C target temp (100 mK) FOV (Field of view) 22.5 H x 31 V IFOV (Spatial resolution) 3.39 mRad Temperature measurement range -20 C to +350 C -20 C to +250 C (-4 F to +482 F) (not calibrated below -10 C) (-4 F to +662 F) Temperature measurement accuracy 2 C or 2 % (at 25 C nominal, whichever is greater) Focus mechanism IR-OptiFlex focus system Focus-free 1.2 m (4 ft) and beyond PIP, FULL IR, FULL VISIBLE, PIP (1.2 m (4 ft) to 4.6 m IR-Fusion technology PIP, FULL IR, FULL VISIBLE No, full IR only AutoBlend (15 ft)), FULL IR, FULL VISIBLE High temperature, Color alarms High temperature low temperature, isotherm Blue-Red, Grayscale, Inverted Grayscale, High-contrast, Hot Standard palettes Blue-Red, Ironbow, Grayscale, Amber Metal, Ironbow, Amber, Inverted Amber Blue-Red, Grayscale, Inverted Grayscale, High-contrast, palettes Ultra Contrast Blue-Red, Grayscale, Ironbow Hot Metal, Ironbow, Amber, Inverted Amber Hot/cold markers Yes User definable spot markers Three on camera and in SmartView in SmartView only Centerpoint Yes Centerbox (MIN/AVG/MAX) Yes Level and span control Manual and auto Minimum span in auto mode 5 C Minimum span in manual mode 2.5 C Minimum IR focus distance 15.25 cm (6 in) 122 cm (48 in) Weight 0.726 kg (1.6 lb) Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in) LCD display 3.5 inch diagonal (portrait format) Visible camera 2 megapixel industrial-grade N/A Minimum parallax ~45.7 55.9 cm (~ 18 in 22 in) ~122 cm (48 in) N/A IR-PhotoNotes annotation system Yes (3 images) Laser pointer Yes Torch Yes Electronic (cardinal) compass Yes Emissivity correction Yes Transmission correction Yes Background (reflected) compensation Yes Voice annotation (audio) Yes (60 seconds) per image Streaming USB video Multi-mode video output output (infrared, visible and IR-Fusion modes) Multi-mode video recording Yes (AVI with MPEG encoding, up to 5 minutes) (standard avi w/ mpeg encoding) Yes, radiometric .is3 for Multi-mode video recording approx. 2.5 to 5 minutes de- (radiometric .is3) pending upon thermal scene Memory review thumbnail review Battery (field-replaceable, Two One rechargeable) Battery life 4+ hours (each)* External battery charging base Yes Optional (accessory) Charging power supply Yes *Assumes 50% brightness of LCD 2 Fluke Corporation Ti125, Ti110, Ti105 Industrial/Electrical and Ti100 General Use Thermal Imagers