Fluke Industrial Thermal Imagers Models: Ti32, Ti25 and Ti10 Technical Data High performance thermal imagers have never been this affordable. This rugged. Or, this easy to use until now. We, at Fluke, are never satisfied leaving the best tools in the hands of the elite, which is why we recently added a new member to our thermal imaging family. The new Fluke Ti32 combines a powerful 320x240 sensor into the award winning, rugged design of the Ti25 and Ti10, delivering the first industrial grade, high performance thermal imager. The result is strikingly crisp, detailed images that, blended with our patented IR-Fusion , are sure to make a lasting impression. Dont take our word for itsee it yourself Ti32 Fluke thermal imagers are designed, tested, and manufactured in the USA, and feature a two year warranty. Work in a harsh environment Dont worry. These meet the stringent quality standards that Fluke prod- ucts are known for worldwide. Able to withstand a 2 meter (6.5 foot) Ti25 drop, they also meet the requirements for an IP54 rating against dust and moisture. For added versatility and special applications, the Ti32 includes two Industrial, mechanical, electromechanical and general field-swappable, rechargeable batteries. Use the optional telephoto and building maintenance. wide-angle lenses to bring distant and wide views into sharp focus. Process, refractory insulation, tank and vessel levels, steam systems Incredible performance at unbelievably low prices. and traps, pipes and valves, etc. Electrical, unbalanced loads, Fluke. Not just infrared, infrared you can use. overloaded systems, wiring mistakes or component failure, etc. IR-Fusion Technology, standard on ALL Fluke thermal imagers More than picture in picture Not all fusion is created equal Infrared images alone can be difficult to under- Dont be fooled by imitators. Patented IR-Fusion stand, which is why Fluke pioneered IR-Fusion, is the only solution with physical parallax cor- a revolutionary marriage of visible and infrared rection, enabling the perfect alignment and images never before seen in commercial or blending of both infrared and visible images. industrial thermal imagers. Automatically While many manufacturers have attempted to capturing a visible image with every infrared duplicate Fluke IR-Fusion, none have been able image allows to you always know exactly what to match it. Turn to Fluke IR-Fusion to deliver the youre looking at. industrys best thermal images.Detailed specifications Ti32 Ti25 Ti10 Temperature Temperature measurement range -20 C to +600 C (-4 F to +1112 F) -20 C to +350 C (-4 F to +662 F) -20 C to +250 C (-4 F to +482 F) (not calibrated below -10 C) Temperature measurement 5 C or 5 % (at 25 C nominal, 2 C or 2 % (at 25 C nominal, whichever is greater) accuracy whichever is greater) On-screen emissivity correction Yes On-screen reflected background Yes temperature compensation On-screen transmission correction Yes Imaging performance Image capture frequency 9 Hz refresh rate or 60 Hz refresh rate 9 Hz refresh rate depending upon model variation Detector type 320 X 240 Focal Plane Array, uncooled 160 X 120 Focal Plane Array, uncooled microbolometer microbolometer Thermal sensitivity (NETD) 0.05 C at 30 C target temp. (50 mK) 0.1 C at 30 C target temp. (100 mK) 0.2 C at 30 C target temp. (200 mK) Infrared spectral band 7.5 m to 14 m (long wave) Visual (visible light) camera Industrial performance 2.0 megapixel Industrial performance 1.3 megapixel Minimum focus distance 46 cm (approx. 18 in) Standard infrared lens type Field of view 23 x 17 Spatial resolution (IFOV) 1.25 mRad 2.5 mRad 2.5 mRad Minimum focus distance 15 cm (approx. 6 in) Optional telephoto infrared lens type Field of view 11.5 x 8.7 Spatial resolution (IFOV) 0.63 mRad Minimum focus distance 45 cm (approx. 18 in) Optional wide-angle infrared lens type Field of view 46 x 34 Spatial resolution (IFOV) 2.50 mRad Minimum focus distance 7.5 cm (approx. 3 in) Focus mechanism Manual, one-handed Smart Focus capability Image presentation Palettes Standard Ironbow, Blue-Red, High Contrast, Ironbow, Blue-Red, High Contrast, Ironbow, Blue-Red, Amber, Amber Inverted, Hot Metal, Amber, Hot Metal, Grayscale High Contrast, Grayscale Grayscale, Grayscale Inverted Ironbow Ultra, Blue-Red Ultra, High Con- Ultra Contrast trast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra Level and span Smooth auto-scaling and manual scaling of level and span Fast auto toggle between manual Yes and auto modes Fast auto-rescale in manual mode Yes Minimum span (in manual mode) 2.5 C (4.5 F) 5 C (9 F) Minimum span (in auto mode) 5 C (9 F) 10 C (18 F) IR-Fusion information Automatically aligned (parallax Yes corrected) visual and IR blending Picture-In-Picture (PIP) Three levels of on-screen IR blending displayed in center of LCD 100 % IR displayed in center of LCD Full screen infrared Three levels of on-screen IR blending displayed on LCD 100 % IR displayed on LCD Color alarms (temperature alarms) High-temperature alarm (user-selectable) Voice annotation 60 seconds maximum recording time per image reviewable playback on imager Image capture and data storage The Ti32 allows user to adjust palette, The Ti25 allows user to adjust palette, blending, level, span, IR-Fusion mode, blending, level, span, IR-Fusion mode, emissivity, and reflected background emissivity, and reflected background temperature compensation, and temperature compensation on a captured transmission correction on a captured image before it is stored. image before it is stored. Image capture, review, save One-handed image capture, review, and save capability mechanism Storage medium SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images transferrable to PC via included multi-format USB card reader File formats Non-radiometric (.bmp) or (.jpeg) or Non-radiometric (.bmp) or fully-radiometric (.is2) fully-radiometric (.is2) No analysis software required for No analysis software required for non-radiometic bitmap (.bmp) files non-radiometric (.bmp and .jpeg) files Export file formats w/SmartView BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF software Memory review Thumbnail view navigation and Sequential image navigation and review review selection 2 Fluke Corporation Ti32, Ti25 and Ti10 Industrial Thermal Imagers