Current Clamps
AC Models
New New
i5s i200 i200s i400 i400s i1000s i2000ex i3000ex i3000s
Specications
i5s i200 i200s i400 i400s i1000s i2000 ex i3000s ex-24 i3000s
i3000s ex-36
Nominal current range(s) 5 A 200 A 20 A 400 A 40 A 10 A 20 A 30 A 30 A
200 A 400 A 100 A 200 A 300 A 300 A
1000 A 2000 A 3000 A 3000 A
Continuous AC current range 0.01 A - 6 A 0.5 A - 200 A 0.1 - 24 A 5 A - 400 A 0.5 - 40 A 0.1 A - 10 A 1 A - 20 A 1 A - 30 A 1 A - 30 A
0.5 A - 200 A 5 A - 400 A 0.1 A - 100 A 2 A - 200 A AC RMS 2 A - 300 A AC RMS 1 A - 300 A
1 A - 1000 A 30 A - 2000 A 30 A - 3000 A 1 A - 2400 A
Highest current 70 A 240 A 240 A 1000 A 1000 A 2000 A 2500 A AC RMS 3500 A AC RMS 4000 A
Lowest measurable current 10 mA 0.5 A 0.5 A 1 A 0.5 A 0.1 1 A 1 A 1 A
1)
Basic accuracy (48-65 Hz) 1% 1% + 0.5 A 1.5% + 0.5 A 2% + 0.15 2% + 0.15 1% + 1 A 1% 1% 2% + 2 A
Useable frequency 40 Hz - 5 kHz 40 Hz 10 kHz 40 Hz 10 kHz 45 Hz - 3 kHz 45 Hz - 3 kHz 5 Hz 100 kHz 10 Hz - 20 kHz (-3dB) 10 Hz - 50 kHz (-3dB) 10 Hz - 100 kHz
Max. working voltage 600 V AC 600 V AC 600 V AC 1000 V 1000 V 600 V AC 600 V AC RMS 600 V AC RMS 600 V AC
Maximum conductor diameter 15 mm 20 mm 20 mm 32 mm 32 mm 54 mm 178 mm Flex-24 178 mm 64 mm
Flex-36 275 mm
Output level(s) 400 mV/A 1 mA/A 100 mV/A 1 mA/A 10 mV/A 100 mV/A 100 mV/A 100 mV/A 10 mV/A
10 mV/A 1 mV/A 10 mV/A 10 mV/A 10 mV/A 1 mV/A
1 mV/A 1 mV/A 1 mV/A 0.1 mV/A
Batttery, battery life 200 hours 400 hours
Output cable (m) 2.5 1.5 2.0 1.5 2.5 1.6 0.5 0.5 2.1
Shrouded banana plugs n/a
BNC adapter n/a
BNC to banana adapter included n/a
Safety CAT III, 600 V CAT III, 600 V CAT III, 600 V CAT III 1000V / CAT III 1000V / CAT III, 600 V CAT III, 600 V CAT III, 600 V CAT III, 600 V
CAT IV 600 V CAT IV 600 V
1)
Basic Accuracy: % reading + oorspec
Current Clamp Compatibility Chart
AC Models
i5S
i200
i200s
i400
22222222 2 222
i400s
i1000s 22222222 2 222
i2000ex
i3000s
i3000ex
AC/DC Models
i30
i30s
22222222 2 222
80i-110s
i410 / i410 kit 33 111
33 111
i1010 / i1010 kit
Other
22222222 2 222
90i-610s
1 For DC only
2 Requires PM 9081
3 Requires PM 9082
114/115/115/117
175/177/179
187/189
27
8845A/8846A
77 IV
83V/87V
88V
43B
430 Series
120 Series
190 Series
1577/1587
715
724
725
741B/743B/744
787
789Current Clamps
AC/DC Models
New New
80i-110s i30 i30s i410 i1010
Specications
80i-110s i30 i30s i410 i1010
Measurement type Hall sensor Hall sensor Hall sensor Hall sensor Hall sensor
Nominal current range(s), 10 A, AC/DC 20 A AC RMS or DC 20 A AC RMS or DC 400 A, AC/DC 600 A, AC
100 A, AC/DC 1000 A, DC
Continuous current range 0.1A 10 A AC/DC 30 A AC Peak 30 A AC Peak 1 A 400 A AC/DC 1 A 600 A, AC
1 A 100 A AC/DC 1 A 1000 A, DC
Highest current 140 A 2 kHz 30 A AC Peak 30 A AC Peak 400 A 1000 A
Lowest measurable current 0.1 A 50 mA 50 mA 0.5 A 0.5 A
1)
Basic accuracy 3% + 50 mA (@ 10 A) 1% of reading 2mA 1% of reading 2mA 3.5% + 0.5 A 2% + 0.5 A
Useable frequency DC 100 kHz DC to 20 kHz (-0.5dB) DC to 100 kHz (-0.5dB) DC 3 kHz DC 10 kHz
Zero error adjustment manual adjust via thumbwheel manual adjust via thumbwheel
Max. working voltage 600 V 300 V AC RMS 300 V AC RMS 600 V 600 V
Maximum conductor diameter 11.8 mm 19 mm 19 mm 30 mm 30 mm
2 x 25 mm 2 x 25 mm
Output level(s) 100 mV/A 100 mV/A 100 mV/A 1 mV/A 1 mV/A
10 mV/A
Battery, battery life 9 V, 55 h 30 hours typical 30 hours typical 9 V, 60 h 9 V, 60 h
Output cable length (m) 1.6 1.5 2 1.6 1.6
Shrouded banana Plugs n/a
BNC adapter n/a
BNC to banana adapter included n/a
Safety CAT II, 600 V CAT III, 300 V CAT III, 300 V CAT III, 600 V CAT III, 600 V
CAT III, 300 V
1)
Basic Accuracy: % reading + oorspec
New
i410 Kit AC/DC Current Clamp i3000ex, 4-pack
(400A) with soft case The perfect accessory for three-phase
measurement tools
i1010 Kit AC/DC Current Clamp
The ex clamps t around bus bars and
(1000A) with soft case
large or hard-to-reach conductors
Combination of current clamp with Buy 4-pack and save 35% on the price
carrying case of the individual items
Zippered soft case with moveable divider
Soft case is large enough to hold a meter
i5sPQ3 AC Current Clamp, 3-pack
A pack of 3 pieces of the i5s current clamps,
specially congured to provide low current
accuracy while taking measurements on
secondary current transformers. This
cost-saving 3-pack is perfect for use with
3-phase tools such as the Fluke 434 or
Fluke 435.
All accessories have a one year warranty
10014-eng Rev. 08