ESP CCTV Series Application Use these protectors on the video cable to outdoor CCTV cameras and central control and monitoring equipment. Installation Connect in series with the CCTV cable in a convenient place close to the equipment being protected. For outdoor CCTV cameras, protectors should be mounted in the junction box, or in a separate enclosure, close to the camera. Protect central control and monitoring equipment inside the Combined Category D, C, B tested protector (to BS EN 61643) building by installing protectors on suitable for coaxial CCTV cables with BNC connectors (ESP CCTV/B) all incoming or outgoing lines, or twisted pair CCTV lines (ESP CCTV/T) on systems with either an either: earthed or an isolated screen. Not suitable for use on broadcast, a) near where they enter or leave satellite or cable TV systems. For use at boundaries up to LPZ 0 to A the building, or protect against flashover (typically the service entrance location) b) close to the equipment being through to LPZ 3 to protect sensitive electronic equipment. protected (or actually within its control panel) Features and benefits DIRTY CLEAN Very low let-through voltage (enhanced protection to BS EN 62305) between all lines - Full Mode protection From line To equipment Full mode design capable of handling partial lightning currents as well as allowing continual operation of protected equipment Earth Repeated protection in lightning intense environments Series connection for ESP CCTV/B 100 MHz bandwidth prevents the degradation of high frequency signals DIRTY CLEAN Low in-line resistance to minimise unnecessary reductions in signal strength and maximise signalling distance Very low reflection coefficient/VSWR ensure that the protector doesnt From line To equipment disrupt system operations Earth Series connection for ESP CCTV/T Suitable for either earthed or isolated screen systems Sturdy, conductive ABS housing for 2 way shielding - preventing Accessories emissions & providing signals with immunity from external interference Convenient holes for flat mounting on base or side When CCTV protectors are installed in groups, or alongside Built-in DIN rail foot for easy installation on a top hat DIN rail protectors for signal and mains ESP CCTV/T has colour coded terminals for a quick and easy installation power lines, these can be check - grey for the dirty (line) end and green for the clean end mounted and earthed simultaneously on a CME kit. Substantial earth stud to enable effective earthing A CME 4 will accommodate the Integral earthing plate for enhanced connection to earth via CME kit video, telemetry and power ESP CCTV/B has Network Rail Approval PA05/02510. protectors to a camera. NRS PADS reference 086/023410 If protectors cannot be incorporated within an existing panel or enclosure, WBX enclosures are available for up to 4, 8, 16 or 32 protectors and Protectors for the video (ESP CCTV/B, left), camera telemetry (ESP 06E, centre) and the low current mains power their associated CME kit. The (ESP 240-5A, right) inputs to a camera, installed together WBX 4/GS is a secure IP66 on a CME 4 mounting and earthing kit. Note that the enclosure suitable for a CME 4 protectors have been cross bonded to the metalwork of and associated protectors. the pole (out of shot) Furse, Wilford Road, Nottingham, NG2 1EB Tel: +44 (0)115 964 3700 Email: enquiry furse.com Web: www.furse.comESP CCTV Series Technical specification NEW NEW NEW NEW NEW NEW Electrical specification ESP CCTV/B ESP CCTV/B-15V ESP CCTV/B-30V ESP CCTV/B-50V ESP CCTV/T ESP CCTV/T-15V ESP CCTV/T-30V ESP CCTV/T-50V 1 Nominal voltage (peak-peak) 1 V 2 V 2 Maximum working voltage Uc (peak) 7.79 V 16.7 V 36.7 V 56.7 V 7.79 V 16.7 V 36.7 V 56.7 V Current rating (signal) 300 mA In-line resistance (10%) 1 inserted in coax inner 1 per line 3 Bandwidth (-3 dB 75 system) > 100 MHz Voltage standing wave ratio < 1.2:1 Transient specification ESP CCTV/B ESP CCTV/B-15V ESP CCTV/B-30V ESP CCTV/B-50V ESP CCTV/T ESP CCTV/T-15V ESP CCTV/T-30V ESP CCTV/T-50V 4 Let-through voltage (all conductors) Up C2 test 4 kV 1.2/50 s, 2 kA 8/20 s to 39.5 V 55.0 V 78.0 V 105.0 V 39.5 V 55.0 V 78.0 V 105.0 V BS EN/EN/IEC 61643-21 C1 test 1 kV, 1.2/50 s, 0.5 kA 8/20 s to 26.0 V 42.0 V 66.5 V 93.5 V 26.0 V 42.0 V 66.5 V 93.5 V BS EN/EN/IEC 61643-21 B2 test 4 kV 10/700 s to 16.0 V 27.2 V 47.5 V 73.6 V 16.0 V 27.2 V 47.5 V 73.6 V BS EN/EN/IEC 61643-21 5 5 kV, 10/700 s 17.0 V 28.2 V 49.5 V 76.2 V 17.0 V 28.2 V 49.5 V 76.2 V 6 Maximum surge current D1 test 10/350 s to BS EN/EN/IEC 61643-21 - per signal wire 2.5 kA 2.5 kA - per pair - 5 kA 8/20 s to ITU (formerly CCITT), - per signal wire 10 kA 10 kA - per pair - 20 kA Electrical specification ESP CCTV/B variants ESP CCTV/T variants Temperature range -40 to +80 C Connection type Coaxial BNC female Screw terminal 2 Conductor size (stranded) Not applicable 2.5 mm Earth connection M6 stud Casing material Conductive ABS UL94 V-0 Weight - unit 0.08 kg Weight - packaged (per 10) 0.9 kg Dimensions 11 NNoommiinnaall vvoollttaaggee ((DDCC oorr AACC ppeeaakk)) mmeeaassuurreedd aatt <<1100 AA lleeaakkaaggee.. 22 MMaaxxiimmuumm wwoorrkkiinngg vvoollttaaggee ((DDCC oorr AACC ppeeaakk)) mmeeaassuurreedd aatt 55 mmAA lleeaakkaaggee.. 54 mm 54 mm 54 mm 33 CCaappaacciittaannccee << 3300 ppFF.. 38 mm 38 mm 38 mm 44 TThhee mmaaxxiimmuumm ttrraannssiieenntt vvoollttaaggee lleett--tthhrroouugghh ooff tthhee pprrootteeccttoorr tthhrroouugghhoouutt tthhee tteesstt ((1100%%)),, lliinnee ttoo lliinnee && lliinnee ttoo eeaarrtthh.. SSccrreeeenn ttoo eeaarrtthh lleett--tthhrroouugghh vvoollttaaggee wwiillll bbee uupp ttoo 660000 VV ((wwiitthh 55 kkVV 1100//770000 tteesstt)),, wwhheenn 105 mm 105 mm 1 pprrootteeccttoorr iiss ccoonnffiigguurreedd ffoorr uussee wwiitthh nnoonn--eeaarrtthheedd oorr M4 clearance M4 clearance iissoollaatteedd ssccrreeeenn ssyysstteemmss.. RReessppoonnssee ttiimmee << 1100 nnss.. 55 TTeesstt ttoo IIEECC 6611000000--44--55::22000066,, IITTUU--TT ((ffoorrmmeerrllyy CCCCIITTTT)) 144 mm 120 mm 144 mm KK..2200,, KK..2211 aanndd KK..4455,,TTeellccoorrddiiaa GGRR--11008899--CCOORREE,, IIssssuuee 22::22000022,, AANNSSII TTIIAA//EEIIAA//IISS--996688--AA::22000022 ((ffoorrmmeerrllyy FFCCCC PPaarrtt 6688)).. 19 mm 66 TThhee iinnssttaallllaattiioonn aanndd ccoonnnneeccttoorrss eexxtteerrnnaall ttoo tthhee pprrootteeccttoorr mmaayy lliimmiitt tthhee ccaappaabbiilliittyy ooff tthhee pprrootteeccttoorr.. 109 mm 109 mm 1 M4 clearance M4 clearance CCTV/B CCTV/T Camera telemetry or control lines should be protected with a suitable Lightning Barrier from the ESP D or E Series. Protectors for the power supply to individual cameras (e.g. ESP 240-16A) and the mains supply to the control room (e.g. ESP 240 D1) are available. For coaxial RF (ESP RF Series) cable protectors and CATV systems (ESP CATV/F) are also available. Furse, Wilford Road, Nottingham, NG2 1EB Tel: +44 (0)115 964 3700 Email: enquiry furse.com Web: www.furse.com