NNeexxeennssooss LL442200,, PPtt TTeemmppeerraattuurree SSeennssoorr aaccccoorrddiinngg ttoo DDIINN EENN 6600775511 Temperature range -50 C to +400 C Excellent long term stability and low drift L series Pt-RTDs are designed for volume applications where long term stability, interchangeability and accuracy over a High accuracy and interchangeability large temperature range are vital. Typical applications include High vibration and shock resistance Energy Management, HVAC, Food and Beverage, Medical and Optimized for soldering connection Industrial equipment. AgPd lead wires assure problem-free connection via soldering and other processes. NNoommiinnaall RReessiissttaannccee RR TToolleerraannccee CCllaassss OOrrddeerr NNuummbbeerr PPaacckkaaggiinngg Pt1000 F 0.1 (Class 1/3 B) 32207587 VCI-Plastic bag F 0.15 (Class A) 32207582 VCI-Plastic bag F 0.3 (Class B) 32207704 VCI-Plastic bag The measuring point for the nominal resistance is 8 mm from the end of the sensor body. TTeemmppeerraattuurree RRaannggee ooff TToolleerraannccee CCllaassss DDiimmeennssiioonnss aanndd TToolleerraanncceess iinn mmmm Tolerance Class F 0.1 (1/3 B) 0 C to +150 C L: 3.9 0.15 Tolerance Class F 0.15 (A) -50 C to +300 C W1: 1.9 0.2 Tolerance Class F 0.3 (B) -50 C to +400 C H: 1.0 +0.3 -0.2 The specified tolerance classes refer to continuous operation. LL: 10 1.0 L: 0.25 0.02 TTeemmppeerraattuurree CCooeeffffiicciieenntt W2: 0.8 0.1 TCR = 3850 ppm/K RReessppoonnssee TTiimmee Water (v = 0.4 m/s): t0.5 = 0.08 s t0.9 = 0.25 s Air (v = 2 m/s): t0.5 = 3.5 s t0.9 = 15 s MMeeaassuurriinngg CCuurrrreenntt Pt1000 : 0.1 to 0.3 mA (self-heating has to be considered) Image for illustration purposes only Color, shape and forming of fixing drop may vary Heraeus Nexensos GmbH, Germany Document: 20002220879 Part 001 Version 02 Status: 09/2021 Web: www.heraeus-nexensos.com Contact: nexensos.america heraeus.com Page 1 of 2NNeexxeennssooss LL442200,, PPtt TTeemmppeerraattuurree SSeennssoorr aaccccoorrddiinngg ttoo DDIINN EENN 6600775511 Temperature range -50 C to +400 C LLoonngg--TTeerrmm SSttaabbiilliittyy LLeeaadd TTyyppee The drift of the resistance value at 0 C after a storage for AgPd 1000 hours in air at the declared upper temperature limit is TTeennssiillee SSttrreennggtthh ooff LLeeaaddss not more than the tolerance value of the declared tolerance 8 N class according DIN EN 60751. Typical drift of R(0 C) is 0.04 % after 1000 hours at +400 PPaacckkaaggiinngg C. VCI-Plastic bag Alternative packaging forms on request SSeellff--HHeeaattiinngg 0.3 K/mW at 0 C SSttoorraaggee LLiiffee At least 12 months (after manufacture), when stored under IInnssuullaattiioonn RReessiissttaannccee the recommended conditions. Longer shelf life may be > 100 M at +20 C possible, depending upon actual storage conditions, after > 2 M at +400 C requalification by customer. VViibbrraattiioonn RReessiissttaannccee Nitrogen atmosphere recommended. At least 40 g acceleration at 10 to 2000 Hz, depends on NNoottee installation Other tolerances, values of resistance and wire lengths are SShhoocckk RReessiissttaannccee available on request. At least 100 g acceleration with 8 ms half sine wave, depends on installation Due to random sample measurements, a bending of connection wires may occur (called V-shape). This bending is CCoonnnneeccttiioonn TTeecchhnnoollooggyy batch-dependent and has no influence on the functionality of Soft Soldering the platinum measuring resistor. Note application temperature of the solder CCaalliiffoorrnniiaa PPrrooppoossiittiioonn 6655 WWAARRNNIINNGG WARNING: This product can expose you to chemicals including lead oxide, which is known to the State of California to cause cancer and birth defects or other reproductive harm, and including cobalt oxide, which is known to the State of California to cause cancer. For more information go to www.p65warnings.ca.gov The information provided in this data sheet describes certain technical characteristics of the product, but shall not be qualified or construed as quality guarantee (Beschaffenheitsgarantie) in the meaning of sections 443 and 444 German Civil Code. The information provided in this data sheet regarding measurement values (including, but not limited to, response time, long-term stability, vibration and shock resistance, insulation resistance and self-heating) are average values that have been obtained under laboratory conditions in tests of large numbers of the product. Product results or measurements achieved by customer or any other person in any production, test, or other environment may vary depending on the specific conditions of use. The customer is solely responsible to determine whether the product is suited for the customer s intended use in this respect Heraeus cannot assume any liability. The sale of any products by Heraeus is exclusively subject to the General Terms of Sale and Delivery of Heraeus in their current version at the time of purchase, which is available under www.heraeus.com/gtc or may be furnished upon request. This data sheet is subject to changes without prior notice. Heraeus Nexensos GmbH, Reinhard-Heraeus-Ring 23, 63801 Kleinostheim, Germany Heraeus Nexensos GmbH, Germany Document: 20002220879 Part 001 Version 02 Status: 09/2021 Web: www.heraeus-nexensos.com Contact: nexensos.america heraeus.com Page 2 of 2