Interactive Catalog Replaces Catalog Pages Honeywell Sensing and Control has replaced the PDF product catalog with the new Interactive Catalog. The Interactive Catalog is a power search tool that makes it easier to find product information. It includes more installation, application, and technical Click this icon to try the new information than ever before. Interactive Catalog. Sensing and Control Honeywell Inc. 11 West Spring Street Freeport, Illinois 61032 Amplified Pressure Sensors 180PC Series Miniature Absolute, Differential, Gage/Amplified FEATURES 1 Miniature plastic package 1 Terminal and housing mount styles 1 PCB termination 1 Fully signal conditioned Terminal Mount Housing Mount 180PC SERIES PERFORMANCE CHARACTERISTICS at 8.0 0.01 VDC Excitation, 25C Min. Typ. Max. Units Excitation 7.00 8.00 16 VDC Supply Current --- --- 6 mA Current Sourcing Output --- --- 10 mA Null Offset (184/185PC) 0.95 1.00 1.05 V Null Offset (186PC) 3.45 3.50 3.55 V Null Offset 185PC15AT 2 psia 1.62 1.67 1.72 V 185PC30AT 2 psia 1.28 1.33 1.38 V Output at Full Pressure (184/185PC, G,D) 5.90 6.00 6.15 V Output at Full Pressure (185PC, A only) 5.85 6.00 6.15 V Output at Full Pressure (186PC) 5.90 6.00 6.10 V Span (184/185PC, G,D) 4.95 5.00 5.05 V Span (185PC, A only) 4.90 5.00 5.10 V Span (186PC) --- 5.00 --- V Span (185PC15AT) 4.28 4.33 4.38 V Span (185PC30AT) 4.62 4.67 4.72 V Ratiometricity Error 7 to 8V or 8 to 9V --- 0.50 --- % Span 9 to 12V --- 2.00 --- % Span Temperature Error (Combined null and span) -2% 0 +2% % Span Stability over One Year --- 0.50 --- % Span Response Time --- --- 1.00 msec Weight --- 12 --- grams Short Circuit Protection Output may be shorted indefinately to ground Output Ripple None, DC device Ground Reference Supply and output are common ENVIRONMENTAL SPECIFICATIONS Operating Temperature -40 to +85C (-40 to +185F) Storage Temperature -55 to +125C (-67 to +257F) Compensated Temperature 0 to +50C (32 to +122F) Shock MIL-STD-202, Method 213 (50 g, half sine, 6 msec) Vibration MIL-STD-202, Method 204 (10 to 2000 Hz at 10 g) Media P2 port Wetted materials polyester housing, epoxy adhesive, silicon, borosilicate glass, and silicon-to- glass bond* P2 port Absolute only: Factory sealed vacuum reference, no connection P1 port Dry gases only *Liquid media containing some highly ionic solutions could potentially neutralize the chip-to-glass tube bond. Honeywell1 Sensing and Control 1 1-800-537-6945 USA1 F1-815-235-6847 International 1 1-800-737-3360 Canada 45