HPM Series 32322550 Particulate Matter Sensors Issue G Datasheet FEATURES Standard Compact Laser-based light scattering particle sensing 3 3 Concentration range: 0 g/m to 1,000 g/m Fully calibrated EMC: Heavy industrial level IEC61000 Response time: <6 s Supply current: 80 mA max. Output signal: UART (Universal Asynchronous Receiver/ Transmitter) PM2.5, PM10 output (standard) PM1.0, PM2.5, PM4.0, PM10 output (compact) RoHS compliant REACH compliant DESCRIPTION The Honeywell HPM Series Particulate Matter Sensor is a DIFFERENTIATION laser-based sensor which detects and counts particles using Long life of 10 years offers a more stable operation for light scattering. The detection concentration range is continuous usage 3 3 0 g/m to 1,000 g/m . A laser light source illuminates a Proven EMC performance, based on IEC61000 stable particle as it is pulled through the detection chamber. As operation, 15% accuracy (PM2.5) particles pass through the laser beam, the light reflects off the particles and is recorded on the photo or light detector. POTENTIAL APPLICATIONS The light is then analyzed and converted to an electrical HVAC (commercial and residential) signal to calculate particle concentration. The Honeywell Indoor air quality monitors particle sensor provides information on the particle Handheld air quality monitors concentration for given particle concentration range. Air purifiers (commercial and residential) Automotive cabin air purifiers VALUE TO CUSTOMERS Enables the ability to more accurately and cost- competitively monitor or control environmental particulate Industry-leading long life of 10 years of continuous use Proven EMC performance enables the ability to perform more accurately in a variety of tough industrial environments Faster response time of <6 s allows the HPM Series to respond to environmental conditions in real time Enhanced reliability allows for use in harsh environments Advanced Sensing TechnologiesParticulate Matter Sensors HPM Series Table 1. Specifications Standard Compact HPMA115C0-003 HPMA115S0-XXX Characteristic HPMA115C0-004 Operating principle laser scattering 1,2 Detection PM2.5, PM10 PM1.0, PM2.5, PM4.0, PM10 3 3 PM1.0 in g/m , PM2.5 in g/m , 1, 2 3 3 Output data PM2.5 in g/m , PM10 in g/m 3 3 PM4.0 in g/m , PM10 in g/m 3 3 Concentration range 0 g/m to 1,000 g/m Accuracy (at 25C 5C): 3 3 3 3 3 0 g/m to 100 g/m PM2.5: 15 g/m PM2.5: 15 g/m PM1.0, PM4.0, PM10: 25 g/m 3 3 100 g/m to 1000 g/m PM2.5: 15 % PM2.5: 15 % PM1.0, PM4.0, PM10: 25% Response time <6 s 3 Supply voltage 5 V 0.2 V Switching frequency max. 100 kHz Ripple amplitude max. 20 mV R.M.S noise max. 1 mV (noise bandwidth 10 MHz) Standby current (at 25C 5C) <20 mA Supply current (at 25C 5C) <80 mA Inrush current max. (at 25C 5C) 600 mA Temperature: operating -20C to 50C -4F to 122F -20C to 70C -4F to 158F storage -30C to 65C -22F to 149F -40C to 85C -40F to 185F Humidity (operating and storage) 0 %RH to 95 %RH non-condensing 4 Output protocol UART baud rate: 9600, databits: 8, stopbits: 1, parity: no Operating time: continuous mode 10 years depends on duty cycle intermittent mode Laser class Laser Class 1: IEC/EN 60825-1: 650 nm ESD 4 kV contact, 8 kV air per IEC 61000-4-2 Radiated immunity 1 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3 Fast transient burst 0.5 kV per IEC61000-4-4 Immunity to conducted disturbances 3 V per IEC61000-4-6 radiated emissions Radiated emissions 40 dB 30 MHz to 230 MHz 47 dB 230 MHz to 1000 MHz per CISPR 14 Conducted emissions 0.15 MHz to 30 MHz in compliance with CISPR 14 43 mm x 36,00 mm x 23,7 mm 44 mm x 36 mm x 12 mm Dimensions (L X W X H) 1.69 in x 1.42 in x 0.93 in 1.73 in x 1.42 in x 0.48 in 1 PM2.5 is particulate matter <2.5 m in diameter PM10 is particulate matter <10 m in diameter. 2 3 3 3 PM1.0 in g/m , PM4.0 in g/m , and PM10 in g/m are calculated from PM 2.5 readings. 3 Power supply output should contain one de-coupling capacitor (22 F), and two ceramic CLASS 1 capacitors (100 nF, 10 nF), if ripple amplitude max. or R.M.S. noise max. exceeds specifications. 4 LASER PRODUCT Contact Honeywell for other output options. Table 2. Order Guide Catalog Listing Description HPMA115S0-XXX HPM Series PM2.5 Particulate Matter Sensor, standard size, UART output HPMA115C0-003 HPM Series PM2.5 Particulate Matter Sensor, compact size, UART output, air inlet and air outlet on same side HPMA115C0-004 HPM Series PM2.5 Particulate Matter Sensor, compact size, UART output, air inlet and air outlet on opposite sides 2 sps.honeywell.com/ast