Data Sheet SENCITY Spot-S WiFi Antenna 1356.17.0077 Description Small directional, planar, linear vertical polarized WiFi antenna with 14 dBi gain WLAN IEEE 802.11 a/h/p - WiFi bands 5.15 to 5.975 GHz Rugged design, meets EN 50155 and EN 50125-3 railway standards Fire retardant acc. to EN 45545-2 and NFPA130 For outdoor and indoor applications Ingress protection IP 66 and IP 67 Wall mounting material included Product Configuration Technical Data Electrical Data Band 1 Frequency (MHz) 5150 - 5975 VSWR 1.5 Impedance (Ohm) 50 Gain (dBi) 14 3dB beamwidth (h) () 40 3dB beamwidth (v) () 35 Composite power max (W) 30 Ambient temperature (C) 25 Front to back ratio (dB) 20 Vertical electrical tilt () 0 Ports Port 1 Connector N, jack (female) Polarization vertical General Data Mechanical Data Dimensions (mm) 101 x 81 x 36 (Heigth x Width x Depth) Weight (kg) 0.11 Windload frontal: 15 N at 160 km/h , Wind speed survival: 220 km/h Included mounting material Wall mounting material Environmental Data Environmental conditions indoor/outdoor Operation temperature (C) -40 to 85 Storage temperature (C) -40 to 85 Transport temperature (C) -40 to 85 Flammability rating EN 45545-2 2011/65/EU (RoHS - including compliant 2015/863 and 2017/2102) Lead-free soldered yes WEEE 2012/19/EU special marking needed REACH 1907/2006/EC compliant FLAMMABILITY: EN 45545-2 (2013) HL3 and NFPA130 (2013), also BS 6853 and DIN 5510-2 ENVIRONMENT: EN 50155 (2016) and EN 50125-3 (2003), also EN 60068 related IP RATING: IP 66 / IP 67 (IEC 60529) Document: DOC-0000333819 AZ / PDO AM / date of publication: 14.04.2021 17:43:36 / uncontrolled copy Page 1/2Data Sheet SENCITY Spot-S WiFi Antenna 1356.17.0077 SOLAR RADIATION: EN 50125-3:2004 4.9, 1120 W/m for 20h AIR PRESSURE: EN 50125-3:2004 4.2, Altitude Class A1 (up to 1400m) AIR PULE PRESSURE: EN 50125-3:2004 4.2, 1 kPa/s RAIN: EN 50125-3:2004 4.6, delivery rate: 6 mm/min VIBRATION / SHOCK: EN 50125-3:2004 4.13, position profile:outside the trac POLLUTION: EN 50125-3:2004 4.11, pollution levels: 4B1, 4S1 CORROSION: MIL-F-14072 E Type 1expose MECHANICAL IMPACT (HAMMER IMPACT): EN 60068-2-75 (IEC 62262/2002-02 IK06) Material Data Radome colour RAL 7044 (grey) Radome material PC (Polycarbonate) Related Products 9091.99.0238 Outdoor Spot-S Antenna Down-Sidetilt Bracket 9091.99.0237 L-Bracket for SPOT-S antennas Related Documents Mounting instruction DOC-0000287053 Painting instruction DOC-0000256180 Security instruction DOC-0000278984 Outline drawing DOU-00139088 3D-model DOC-0000846834 Additional Information Following Declaration of Conformity for SENCITY Spot-S antennas are available on request: * Industrial standards EN 60068 / EN 60529 / IEC 61373: Ref. DOC-0000318049 * Railway rolling stock, environmental standards EN 50155 and fire behaviour EN 45545-2k, NFPA130: Ref. DOC-0000380375 * Railway trackside, environmental standards EN 50125-3 and fire behaviour EN 45545-2: Ref. DOC-0000411396 HUBER+SUHNER is certified according to ISO 9001, ISO 14001, AS/EN9100, ISO/TS 16949 and IRIS. www.hubersuhner.com Waiver: Fact and figures herein are for information only and do not represent any warranty of any kind. Document: DOC-0000333819 AZ / PDO AM / date of publication: 14.04.2021 17:43:36 / uncontrolled copy Page 2/2