Data Sheet Flexible RF cable RG 213 /U Item: 22510052 Description RG: RG type RF cables RG213, 50 Ohm, 1 GHz, 85C, 10.3 mm, PVC jacket Technical Data Construction Material Detail Diameter Centre conductor Copper Strand-07 2.25 mm Dielectric PE (Polyethylene) 7.25 mm Outer conductor Copper Braid, 96% 8.1 mm Jacket PVC II (low migration) RAL 9005 - bk 10.3 mm +/- 0.1 Print: HUBER+SUHNER RG 213 U 50 Ohm (production order number) Electrical Data Impedance 50 +/- 2 Operating Frequency 1 GHz Capacitance 101 pF/m Velocity of signal propagation 66 % Signal delay 5.03 ns/m Screening effectiveness 40 dB (up to 1 GHz) 5 kV (at sea level) Operating voltage rms 10 kV (50 Hz/1 min) Test voltage rms Mechanical Data Weight 15.3 kg/100 m Min. bending radius static 50 mm 100 mm Environmental Data Temperature range -25 C ... +85 C Installation temperature -20 C... +60 C Halogen free No 2011/65/EU (RoHS - including compliant 2015/863 and 2017/2102) 1907/2006/EC (REACH) compliant Additional Information MIL reference: M17/189-00001 (former reference: M17/74-RG213) Remarks (For details refer to the HUBER+SUHNER RF CABLES GENERAL CATALOGUE or contact your nearest HUBER+SUHNER partner) Suitable Connectors Cable group U29 7 mm / 50 Ohm Document: DOC-0000177758 AR / PDO N / date of publication: 14.10.2020 18:00:26 / uncontrolled copy Page 1/2Data Sheet Flexible RF cable RG 213 /U Item: 22510052 Matrix typical Attenuation formula: (a*f 0.5 + b*f) and maximum Power CW formula: (p/f 0.5) Coefficients: a = 0.1679 b = 0.0585 f = 1 P at 1GHz = 416 max Frequency Nom. attenuation Nom. attenuation Max. CW power (GHz) (dB / m) (dB / ft) (W) sea level 25 C sea level 25 C sea level 40 C ambient ambient ambient temperature temperature temperature 0,05 0,04 0,012 1860 0,1 0,06 0,018 1316 0,15 0,07 0,022 1074 0,2 0,09 0,026 930 0,25 0,1 0,030 832 0,3 0,11 0,033 760 0,35 0,12 0,037 703 0,4 0,13 0,039 658 0,45 0,14 0,042 620 0,5 0,15 0,045 588 0,55 0,16 0,048 561 0,6 0,17 0,050 537 0,65 0,17 0,053 516 0,7 0,18 0,055 497 0,75 0,19 0,058 480 0,8 0,2 0,060 465 0,85 0,2 0,062 451 0,9 0,21 0,065 439 0,95 0,22 0,067 427 1,0 0,23 0,069 416 HUBER+SUHNER is certified according to ISO 9001, ISO 14001, AS/EN9100, ISO/TS 16949 and IRIS. www.hubersuhner.com Waiver: Fact and figures herein are for information only and do not represent any warranty of any kind. Document: DOC-0000177758 AR / PDO N / date of publication: 14.10.2020 18:00:26 / uncontrolled copy Page 2/2