SUCOFLEX 104 Variations SUCOFLEX 104, 104P(E) cables that can be universally applied with the widest range of connector types, are available with most ruggedisations. In applications in which flexibility is the critical fac- tor, the cable type SUCOFLEX 104PE must be applied. In conjunction with the Q adaptor, which is a simple system for exchanging the connectors as well as the special connections for Agilent Technologies analysers, the two types constitute the ideal choice for use as test cables on network analysers. For assemblies used in EMC-critical applications, the M ruggedisation is available. This results in yet another considerable improvement of the high screening effectiveness below 100 MHz. Mechanical and general data SUHNER type Cable Rugge- Temperature Weight Outer Bending radii disation min. (C) max. (C) kg/100m dia. (mm) static (mm) dyn. (mm) SF 104 SF 104 - -55 +165 8.4 5.50 16 25 SF 104A SF 104 A -40 +85 17.3 10.30 30 50 SF 104E SF 104E - -40 +85 8.3 5.50 16 25 SF 104EA SF 104E A -40 +85 17.2 10.30 30 50 SF 104EM SF 104E M -40 +85 12.1 7.70 40 80 SF 104B SF 104 B -55 +165 18.9 10.00 45 45 SF 104C SF 104 C -25 +135 19.3 10.30 30 50 SF 104D SF 104 D -55 +165 9.6 6.10 20 30 SF 104G SF 104 G -50 +100 22.6 13.70 60 100 SF 104P SF 104P - -55 +165 6.9 5.50 16 25 SF 104PE SF 104PE - -40 +85 6.8 5.50 16 25 SF 104PEA SF 104PE A -40 +85 17.1 10.30 30 50 SF 104PB SF 104P B -55 +165 18.7 10.00 45 45 SF 104PEM SF 104PE M -40 +85 13.6 7.70 40 80 Further information about ruggedisation see pages 128 ff. HUBER+SUHNER Microwave Cables and Assemblies 111 SUCOFLEX 100 SUCOFLEX 104 Order code n/a Cable design 12 3 45 Description Material Diameter 1. Centre conductor Solid silver-plated copper wire CuAg 2. Dielectric Low density PTFE LDPTFE 3. 1st outer conductor Silver-plated copper tape, wrapped CuAg 4. 2nd outer conductor Silver-plated copper braid CuAg 5. Jacket Fluoroethylenepropylene, blue FEP 5.50 mm Marking none Electrical cable data Impedance 50 Ohm Operating frequency 26.5 GHz Capacitance 87 pF/m Velocity of propagation 77 % Time delay 4.3 ns/m Nom. attenuation* coefficient a 0.2291 coefficient b 0.0071 Max. attenuation* coefficient a 0.2520 coefficient b 0.0078 Max. operating voltage 2.6 kVrms Min. screening effectiveness up to 18 GHz 90 dB *Attenuation calculation (dB/m) General cable data Temperature range -55+165 C Weight 8.4 kg/100m Min. bending radius static 16 mm Min. bending radius dynamic 25 mm Suitable connectors Please refer to pages 118 ff 112 HUBER+SUHNER Microwave Cables and Assemblies