Y E A R G U Isolating Signal Converter ISOCON The new ISOCON Isolating Signal Converter can accept a wide range of inputs including 4-20mA, thermocouple, RTD and voltage signals. The units produce a high level DC output of either voltage or current. Universal input/output- user selectable Full 3-Port Isolation Wide range AC or DC Supply Isolated Transmitter Supply Very High Accuracy, Low Cost Only 12.5mm Wide on DIN rail Options and ordering codes ISOCON - 6 90-264VAC supply 3 12-32VAC and 12-36VDC 6 Inputs Description Standard ranges are shown below - contact Sales for others. Full 3 port isolation is standard as is an isolated transmitter supply which can DC/AC Current & Voltage be used to power any standard 2-wire 4-20mA transmitter. Eg 0-20mA, 4-20mA, 0-10mA into 15 The input type and range can be user selected using simple DIL switches 0-1V, 0-10V, 1-5V into 1M inside the unit. All RTD and thermocouple inputs can be fully linearised. Min & Max full scale ranges are: Non-interactive zero and span controls make adjustment of the unit quick and DC Current 0 - 1mA 0 - 60mA simple. Bipolar DC Current 5mA 10mA Other features include optional inversion of input signal an optional second analogue output (see Dualcon data sheet) and an optional Relay alarm output. DC Voltage 0 - 1V 0 - 300V* The unit is supplied with two power supply options either wide ranging ac or Bipolar DC Voltage 5V 10V dc. The ac version operates from any supply from 90 to 264Vac and the dc 2 Wire Pot 0 - 125 0 - 1k version operates from 12 - 32VAC and 12 - 36VDC. 3 Wire Pot 0 - 1k 0 - 100k For specials such as custom linearisation etc. please contact the sales office. *Note: For input voltages greater than 60VDC an IIR-Divider unit must be specified. Thermocouples Types E,J,K,N,R,S,T,B linearised or non-linearised Ranges: Wide range of inputs Cold junction compensation (can be turned off) Upscale or downscale t/c burnout options Resistance Thermometers 2,3 or 4 wire PT100 or PT1000, linearised or non-linearised. Ranges: Wide range of inputs. Upscale or downscale RTD burnout options Outputs DC Current and Voltage 0-20mA, 4-20mA, 0-10mA into maximum 1k 0-10V, 1-5V into a minimum 7k Others available up to a maximum of: Current: 0-20mA. Voltage: 0-10VDC ISOCON/03/03 www.imopc.com A R A N T E EIsolating Signal Converter ISOCON continued Specification Parameter Min Typ Max Comments Supply Voltage 12 24V 36VDC/32VAC 90 to 264 for ac input version Supply Current (mA) 45 85 For 24VDC (260mA for 50ms on startup) Input Impedance (Volt) 1M Dependent on range (Typ=10V) Input Impedance (mA) 15 Dependent on range (Typ=20mA) Volt drop (mA input) 0.3 At 20mA input Output Linearity Error 0.01% 0.05% Temp Coefficient 50ppm/C Time Constant (10-90%) 25ms (fast) 60ms (normal) Selectable fast/normal response Operating Ambient 0C 55C Relative Humidity 0% 90% Isolation Voltage see note 1 1kV Surge Voltage 2.5kV for 50S Transient of 10kV/S Notes Absolute maximum ratings indicate sustained limits beyond which damage to the device may occur Accuracy figures based on 24VDC supply, 4-20mA output with 250 load and 20C ambient. Device is protected against reverse polarity connection. 1/ ISOCON does not provide safety isolation when the input is connected to the mains. Dimensions and connections 12.5 99 Installation Data Mounting DIN Rail TS35 Orientation Any Connections Screw Clamp with pressure plate Conductor size 0.5-4.0mm Insulation 12mm Weight Approx. 95g Connection Details 1. Power Input -ve 2. Power Input +ve 4. Process Input -ve T/C -ve RTD -ve 5. Process Input +ve T/C +ve RTD +ve 3. Trans supply +ve RTD 4th Wire 6. T/C Shield RTD 3rd Wire 10. Output -ve 12. Output +ve ISOCON/03/03 www.imopc.com 114.5