TSic 206/203/201/306/303/301 Temperature Sensor IC For a fully calibrated and accurate low power temperature measurement Benefits & Characteristics Fully calibrated Custom calibration and assembly available Outstanding accuracy of +/- 0.3 K (TSic 30x) Accuracy range of 80 K can be shifted (default: 10 C to 90 C) Very low power consumption Available with digital, analog and ratiometric output signal Excellent long-term stability Illustration Technical Data Operating temperature range:* -50 C to +150 C (+/- 3 C of measurement limits) Accuracy:* TSic 20x +/- 0.5 K in the range of 10 C to 90 C (other ranges on request) TSic 30x +/- 0.3 K in the range of 10 C to 90 C (other ranges on request) Resolution:* 0.1 K Sampling rate:* 10 Hz + + Supply voltage: V = 3 V to 5.5 V, high precision operation in range V = 4.5 V to 5.5 V + Supply current: typ. 30 A at 25 C and V = 3.3 V for minimal self-heating Packaging:* SOP-8 or TO92 (other packaging on request) * Customer specific alternatives available Packaging pin assignment: Pin 1 Pin 2 Pin 3 Pin 4 SOP-8 (5, 6, 7 and 8 not used) V+, Supply voltage Signal Not used GND (3 V to 5.5V) TO92 GND Signal V+, Supply voltage (3 V to 5.5 V) 1/4TSic 206/203/201/306/303/301 Temperature Sensor IC For a fully calibrated and accurate low power temperature measurement Absolute max. rating Min Max + Supply voltage (V ) -0.3 V 6 V Voltages to analog I/O Pins (V , V ) -0.3 V V +0.3 V INA OUTA DDA Storage temperature range (T ) -20 C 80 C STOR Operating conditions Min Typ Max + Supply voltage to GND (V ) 2.97 V 5 V 5.5 V + Supply current (I ) V = 3.3 V, RT 25 A 30 A 60 A V+ Operating temperature range (T ) -50 C +150 C amb Output load capacitance (C ) 15 nF L + 1) External capacitance between V and GND (C ) 100 nF (recommended) V+ Output load resistance between signal and GND 47 kOhm + (or V ) 2) Temperature accuracies TSic 30x TSic 20x T1: +10 C to 90 C +/- 0.3 K +/- 0.3 K T2: -20 C to +110 C +/- 0.6 K +/- 1 K T3: -50 C to +150 C +/- 1.2 K +/- 2 K 1) + Recommended as close to TSic V and GND-Pins as possible 2) The sensor is calibrated at 5 V. The provided accuracy is applicable for a supply voltage between 4.5 V and 5.5 V. The accuracy is smaller with a supply voltage between 2.97 V and 4.5 V. For applications where the best accuracy at 3 V is TM requested, ask for a custom specific 3 V calibrated device. Other TSic products with custom specific calibrations are available upon request e.g. other temperature range for high accuracy. Accuracy at delivery the assembly method can influence the accuracy Order Information - SOP-8 Output signal Analog Analog ratiometric Digital, ZACWire protocol 201/203/206 TSic 201 SOP-8 TSic 203 SOP-8 TSic 206 SOP-8 Order code 030.00038 030.00060 030.00005 301/303/306 TSic 301 SOP-8 TSic 303 SOP-8 TSic 306 SOP-8 Order code 030.00036 030.00024 030.00006 2/4