CPC1973 Power SIP Relay INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description Blocking Voltage 400 V IXYS Integrated Circuits Division and IXYS have P Load Current 0.35 A combined to bring OptoMOS technology, reliability rms On-Resistance (max) 5 and compact size to a new family of high power solid state relays. As part of that family, the CPC1973 is a 1-Form-A solid state relay. The CPC1973 employs optically coupled MOSFET technology Features to provide 2500V of input to output isolation. rms Power SIP Package The optically coupled outputs, that use patented Handle Load Currents Up to 0.35A rms OptoMOS architecture, are controlled by a highly High Reliability efficient GaAIAs infrared LED. The combination of No Moving Parts low on-resistance and high load current handling Low Drive Power Requirements (TTL/CMOS capabilities makes the relay suitable for a variety of Compatible) high performance switching applications. Arc-Free With No Snubbing Circuits 2500V Input/Output Isolation rms No EMI/RFI Generation Machine Insertable, Wave Solderable Approvals UL 508 Recognized Component: File E69938 CSA Certified Component: Certificate 1172007 Applications Industrial Controls Ordering Information Motor Control Part Description Robotics CPC1973Y Power SIP Package (25 per tube) Medical EquipmentPatient/Equipment Isolation Instrumentation Multiplexers Data Acquisition Pin Configuration Electronic Switching I/O Subsystems Meters (Watt-Hour, Water, Gas) IC Equipment Home Appliances 1 2 3 4 - + Switching Characteristics of Normally Open (Form A) Devices Form-A I F 90% 10% I LOAD t t on off Pb e3 DS-CPC1973-R04 1 www.ixysic.comCPC1973 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings ( 25 C) Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage 400 V P the device. Functional operation of the device at conditions Reverse Input Voltage 5 V beyond those indicated in the operational sections of this Input control Current 50 mA data sheet is not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW Isolation voltage Input to Output 2500 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate Linearly 3.33 mw / C Electrical Characteristics Parameter Conditions Symbol Min Typ Max Units Output Characteristics 25C Load Current, Continuous free air I - - 0.35 L A rms Peak t<10ms I - - 3.5 LPK 1 On-Resistance I =350mA R - 3.4 5 L ON Off-State Leakage Current V =400V I -- 1 A L LEAK Switching Speeds - t -5 ms ON Turn-On I =10mA, V =10V F L Turn-Off t -- 3 ms OFF Input Characteristics 25C Input Control Current to Activate I =350mA I - - 10 mA L F Input Control Current to Deactivate - I -- - mA F Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Input/Output Characteristics 25C Capacitance Input/Output f=1MHz C -2 - pF I/O 1 Measurement taken within 1 second of on time. Thermal Characteristics Parameter Conditions Symbol Min Typ Max Units Thermal Resistance (junction to case) - R - 1.5 - C/W JC R04 2 www.ixysic.com