CPC1976 AC Power Switch INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description AC Operating Voltage 20 - 240 V rms CPC1976 is an AC Solid State Switch utilizing Load Current 2 A rms dual power SCR thyristor outputs. This device also On-State Voltage Drop 1.15 V (at I = 2A ) rms L rms includes zero-cross turn-on circuitry and is specified Blocking Voltage 600 V with a blocking voltage of 600V . P P In addition, tightly controlled zero-cross circuitry ensures low noise switching of AC loads by Features minimizing the generation of transients. The optically Load Current up to 2A rms coupled input and output circuits provide 3750V of rms 600V Blocking Voltage P isolation and noise immunity between the control and 5mA Sensitivity load circuits. As a result, the CPC1976 is well suited Zero-Crossing Detection for industrial environments where electromagnetic DC Control, AC Output interference would disrupt the operation of plant facility Optically Isolated communication and control systems. TTL and CMOS Compatible Low EMI and RFI Generation Approvals High Noise Immunity UL Recognized Component: File E69938 Machine Insertable, Wave Solderable CSA Certified Component: File 043639 Ordering Information Applications Part Description Programmable Control CPC1976Y 4-Pin (8-Pin Body) SIP (25/Tube) Process Control Power Control Panels Remote Switching Pin Configuration Gas Pump Electronics Contactors Large Relays Solenoids ZC Motors Heaters 1 3 4 2 LED + LED AC Load AC Load Zero-Cross Waveforms Control AC Line Load Current Voltage Across Relay DS-CPC1976-R05 1 www.ixysic.comCPC1976 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to the Blocking Voltage (V ) 600 V DRM P device. Functional operation of the device at conditions beyond Reverse Input Voltage 5 V those indicated in the operational sections of this data sheet is Input Control Current 50 mA not implied. Peak (10ms) 1 A 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 2400 mW Isolation Voltage, Input to Output 3750 V rms ESD, Human Body Model 4 kV 2 2 i t for Fusing (1/2 Sine Wave, 50Hz) 8 A s Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 20 mW / C Electrical Characteristics 25C Parameters Conditions Symbol Min Typ Max Units Output Characteristics Load Current, Continuous V =120-240V I 0.070 - 2 A L rms L rms Maximum Surge Current t < 16ms I -- 20 A PK Off State Leakage Current V I -- 10 A DRM LEAK On-State Voltage Drop I =2A - - 1.1 1.25 V L P P Critical Rate of Rise - dv/dt 1000 1200 - V/s Switching Speeds Turn-on I = 5 mA t - - 0.5 cycles F on Turn-off t - - 0.5 cycles off 1 Zero-Cross Turn-On Voltage 1st half-cycle - - 7 20 V Subsequent half-cycle - - - 5 V Holding Current - I - - 75 mA H Latching Current - I - - 100 mA L Operating Frequency - 20 - 500 Hz Load Power Factor for 2 Guaranteed Turn-On 60Hz PF 0.25 - - - Input Characteristics 3 Input Control Current to Activate 60Hz I -- 5 mA F Input Drop-out Voltage - - 0.8 - - V Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance - C -- 3 pF I/O 1 Zero Cross 1st half-cycle <100Hz. 2 Snubber circuits may be required at low power factors. 3 For high-noise environments, or for high-frequency operation, use I > 10mA. F R05 2 www.ixysic.com