CPC1976YX6 Rapid Turn-On AC Power Switch INTEGRATED CIRCUITS DIVISION Parameter Rating Units Description AC Operating Voltage 20 - 240 V rms CPC1976YX6 is an AC Solid State Switch utilizing Load Current 2 A rms dual power SCR outputs. This device features Rapid On-State Voltage Drop 1.25 V (at I = 2A ) P L P Turn-On (non-zero-cross) control of the output SCRs, Blocking Voltage 600 V which makes it ideal for precisely switching AC loads P independent of the load voltage phase. The optically coupled input and output circuits Features provide 3750V of isolation and noise immunity rms Load Current up to 2A rms between the control and load circuits. As a result, the 600V Blocking Voltage P CPC1976YX6 is well suited for industrial environments High Surge Current: 20A where electromagnetic interference would disrupt the Rapid Turn-On (Non-Zero-Cross Turn-On) operation of plant facility communication and control 5mA Sensitivity systems. Creepage Distance: 0.125 on Output Pins DC Control, AC Output Optically Isolated Approvals TTL and CMOS Compatible UL Recognized Component: File E69938 Low EMI and RFI Generation CSA Certified Component: Certificate 1172007 High Noise Immunity Machine Insertable, Wave Solderable Ordering Information Part Description Applications CPC1976YX6 4-Pin (8-Pin Body) SIP (25/Tube) HVAC Control (Heating, Ventilation, Air Conditioning) Lighting Programmable Control Pin Configuration Process Control Power Control Panels Remote Switching Gas Pump Electronics R Contactors Large Relays 1 2 3 4 Solenoids LED + LED AC Load AC Load Motors Heaters Rapid Turn-On (Non-Zero-Cross) Waveforms Control AC Load Voltage Load Current Voltage Across Relay DS-CPC1976YX6-R02 1 www.ixysic.comCPC1976YX6 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Ratings Units excess of these ratings can cause permanent damage to the Blocking Voltage (V ) 600 V DRM P device. Functional operation of the device at conditions beyond Reverse Input Voltage 5 V those indicated in the operational sections of this data sheet is Input Control Current 50 mA not implied. Peak (10ms) 1 A di/dt Critical Rate of Rise 40 A/s of On-State Current 1 Input Power Dissipation 150 mW 2 Total Power Dissipation 2400 mW ESD, Human Body Model 4 kV 2 2 i t for Fusing (1/2 Sine Wave, 60Hz) 3.5 A s Isolation Voltage, Input to Output 3750 V rms Operational Temperature -40 to +85 C Storage Temperature -40 to +125 C 1 Derate linearly 1.33 mW / C 2 Derate linearly 20 mW / C Electrical Characteristics 25C Parameters Conditions Symbol Min Typ Max Units Output Characteristics Load Current, Continuous V =20-240V I 0.070 - 2 A L rms L rms Maximum Surge Current t < 16ms I -- 20 A PK Off State Leakage Current V I -- 10 A DRM LEAK On-State Voltage Drop I =2A - - 1.1 1.25 V L P P Critical Rate of Rise - dv/dt 1000 1200 - V/s Switching Speeds I = 5 mA, Resistive F Turn-on t - 20 500 s on V =20V, 60Hz L Turn-off t - - 0.5 cycle off Holding Current - I - - 75 mA H Latching Current - I - - 100 mA L Operating Frequency - 20 - 500 Hz Input Characteristics 1 Input Control Current to Activate 60Hz I -- 5 mA F Input Drop-out Voltage - - 0.8 - - V Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance - C -- 3 pF I/O 1 For high-noise environments, or for high-frequency operation, use I > 10mA. F R02 2 www.ixysic.com