DSEI 2x 121-02A I = 2x 123 A Fast Recovery FAVM V = 200 V Epitaxial Diode (FRED) RRM t = 35 ns rr miniBLOC, SOT-227 B V V Type RSM RRM V V 200 200 DSEI 2x 121-02A E72873 Symbol Test Conditions Maximum Ratings (per diode) Features International standard package I T = T 150 A FRMS VJ VJM I T = 70C rectangular, d = 0.5 123 A miniBLOC (ISOTOP compatible) FAVM C I t < 10 s rep. rating, pulse width limited by T 600 A FRM P VJM Isolation voltage 2500 V~ 2 independent FRED in 1 package I T = 45C t = 10 ms (50 Hz), sine 1200 A FSM VJ Planar passivated chips t = 8.3 ms (60 Hz), sine 1300 A Very short recovery time T = 150C t = 10 ms (50 Hz), sine 1080 A VJ Extremely low switching losses t = 8.3 ms (60 Hz), sine 1170 A Low I -values RM 2 2 I t T = 45C t = 10 ms (50 Hz), sine 7200 A s Soft recovery behaviour VJ 2 t = 8.3 ms (60 Hz), sine 7100 A s 2 T = 150C t = 10 ms (50 Hz), sine 5800 A s VJ 2 t = 8.3 ms (60 Hz), sine 5700 A s T -40...+150 C VJ T 150 C VJM T -40...+150 C stg P T = 25C 250 W tot C V 50/60 Hz, RMS 2500 V~ ISOL I 1 mA ISOL M Mounting torque 1.5/13 Nm/lb.in. d Terminal connection torque (M4) 1.5/13 Nm/lb.in. Weight 30 g Symbol Test Conditions Characteristic Values (per diode) typ. max. I T = 25C V = V 1 mA R VJ R RRM T = 25C V = 0.8 V 0.5 mA VJ R RRM T = 125C V = 0.8 V 20 mA VJ R RRM V I = 120 A T = 150C 0.89 0.95 V F F VJ T = 25C 1.10 V VJ V For power-loss calculations only 0.7 V T0 r T = T 2.1 m T VJ VJM R 0.5 K/W thJC R 0.1 K/W thCK t I = 1 A -di/dt = 400 A/s V = 30 V T = 25C 35 50 ns rr F R VJ I V = 100 V I = 100 A -di /dt = 200 A/s 12 15 A RM R F F L 0.05 H T = 100C VJ I rating includes reverse blocking losses at T , V = 0.8 V , duty cycle d = 0.5 FAVM VJM R RRM Data according to IEC 60747 IXYS reserves the right to change limits, test conditions and dimensions. 20170315a 2017 IXYS All rights reserved 1 - 3D DSEI 2x 121-02A miniBLOC, SOT-227 B H Millimeter Inches J A Dim. Nut M4 DIN 934 min max min max Lens Head G A 31.50 31.88 1.240 1.255 K Screw M4x8 B B 7.80 8.20 0.307 0.323 DIN 7985 Z C 4.09 4.29 0.161 0.169 D 4.09 4.29 0.161 0.169 3 4 E 4.09 4.29 0.161 0.169 F 14.91 15.11 0.587 0.595 G 30.12 30.30 1.186 1.193 H 37.80 38.23 1.488 1.505 J 11.68 12.22 0.460 0.481 1 2 K 8.92 9.60 0.351 0.378 L 0.74 0.84 0.029 0.033 M 12.50 13.10 0.492 0.516 N 25.15 25.42 0.990 1.001 O 1.95 2.13 0.077 0.084 E L P 4.95 6.20 0.195 0.244 F Q 26.54 26.90 1.045 1.059 P Q R 4.42 0.155 0.167 3.94 0.179 0.191 S 4.55 4.85 0.968 0.994 T 24.59 25.25 -0.002 0.004 U -0.05 0.10 V 3.20 5.50 0.126 0.217 0.780 0.830 W 19.81 21.08 0.098 0.106 Z 2.50 2.70 U IXYS reserves the right to change limits, test conditions and dimensions. 20170315a 2017 IXYS All rights reserved 2 - 3 T V M W N O S R C