Date:- 28 Jun, 2019 Data Sheet Issue:- 1 WESTCODE An IXYS Company Fast Recovery Diode Types M0659LC400 to M0659LC450 (Old Type No.: SM30-45CXC364) Absolute Maximum Ratings MAXIMUM VOLTAGE RATINGS UNITS LIMITS V Repetitive peak reverse voltage, (note 1) 4000 - 4500 V RRM V Non-repetitive peak reverse voltage, (note 1) 4000 - 4500 V RSM MAXIMUM OTHER RATINGS UNITS LIMITS I Maximum average forward current, T =55C, (note 2) 659 A F(AV)M sink I Maximum average forward current. T =100C, (note 2) 312 A F(AV)M sink I Maximum average forward. T =100C, (note 3) 178 A F(AV)M sink I Nominal RMS forward current, T =25C, (note 2) 1315 A F(RMS) sink I D.C. forward current, T =25C, (note 4) 1108 A F(d.c.) sink I Peak non-repetitive surge t =10ms, V =60%V , (note 5) 7620 A FSM p RM RRM I 8470 A FSM2 Peak non-repetitive surge tp=10ms, VRM10V, (note 5) 2 2 3 2 I t I t capacity for fusing t =10ms, V =60%V , (note 5) 29010 A s p RM RRM 2 2 3 2 I t I t capacity for fusing t =10ms, V 10V, (note 5) 35910 A s p RM T Operating temperature range -40 to +125 C j op T Storage temperature range -40 to +150 C stg Notes:- 1) De-rating factor of 0.13% per C is applicable for T below 25C. j 2) Double side cooled, single phase 50Hz, 180 half-sinewave. 3) Single side cooled, single phase 50Hz, 180 half-sinewave. 4) Double side cooled. 5) Half-sinewave, 125C T initial. j Provisional Data Sheet. Types M0659LC400 to M0659LC450 Issue 1 Page 1 of 11 June, 2019 WESTCODE An IXYS Company Extra Fast Recovery Diode Types M0659LC400 to M0659LC450 Characteristics PARAMETER MIN. TYP. MAX. TEST CONDITIONS (Note 1) UNITS - - 3.0 I =1400A FM V Maximum peak forward voltage V FM - - 2.95 I =1320A FM V Threshold voltage - - 1.71 V T0 r Slope resistance - - 0.925 mW T - - 110 di/dt = 1000A/s, T =25C j V Maximum forward recovery voltage V FRM - - 180 di/dt = 1000A/s - - 100 Rated V RRM I Peak reverse current mA RRM - - 100 Rated V , T =25C RRM j Q Recovered charge - 800 - C rr Q Recovered charge, 50% Chord - 270 350 I =1000A, t =1000s, di/dt=60A/s, C ra FM p I Reverse recovery current - 130 - V =50V, 50% Chord. A rm r t Reverse recovery time, 50% Chord - 4.2 - s rr - - 0.033 Double side cooled R Thermal resistance, junction to heatsink K/W thJK - - 0.066 Single side cooled F Mounting force 10 - 20 kN W Weight - 340 - g t Notes:- 1) Unless otherwise indicated Tj=125C. 2) For other clamp forces consult factory. Provisional Data Sheet. Types M0659LC400 to M0659LC450 Issue 1 Page 2 of 11 June, 2019