MIL-PRF-20/Radial Leads Figure 1 Figure 2 W W T L.D. L.D. L.S. L L L.S. L T L T W W 1.250 Min. L.D. 1.250 Min. L.D. L.S. L.S. Figure 3 Figure 4 HOW TO ORDER Military Type Designation: Established Reliability = CCR05, CCR06, CCR07, CCR08, CCR09 Non-Established Reliability = CC05, CC06, CC07, CC08, CC09 CCR06 183 J R (V) CG Style Capacitance Capacitance Military Standoff Temperature CC = Identifies temperature First two digits are the significant Tolerance Failure Rate Option Characteristic compensating, figures of capacitance. Third digit C = 0.25pF M = 1% per 1000 hours To order standoff ceramic dielectric, Permissible capacitance indicates the additional number D = 0.5pF P = 0.1% per 1000 hours option, place V fixed capacitors. change from capacitance at of zeros. For example, order F = 1% R = 0.01% per 1000 hours at the end of the R = Identifies Established +25C in ppm/C 18,000 pF as 183. (For values G = 2% S = 0.001% per 1000 hours part number. Reliability parts below 10pF use R in place of Characteristic Temp. J = 5% Example: 06 = Numbers identify decimal point, e.g., 1R4 = 1.4pF.) K = 10% CCR05CG332FSV CX 1/ +125C shape and dimension 1/ -55C 2/ CK 250 ppm/C +125C +246.25, -326.25 -55C 2/ CJ 120 ppm/C +125C +116.25, -166.25 -55C 2/ CH 60 ppm/C +125C +55.00, -91.25 -55C 2/ CG 30 ppm/C +125C +27.50, -53.75 -55C 2/ 1/ Not practically measurable. 2/ The ppm/C values for -55C were calculated by dividing ppm by negative 80C. SIZE SPECIFICATIONS Dimensions: Millimeters (Inches) PACKAGING REQUIREMENTS Per MIL Packaging: CCR0X: 100 pcs/bag CC0X: 1000 pcs/bag Case Size Spec Lead Lead MIL-PRF-20 Length Width ThicknessSpacing Diameter (L) (W) (T) (L.S.) (L.D.) CCR05/CC05 4.83.25 4.83.25 2.29.25 5.08.38 .64.05 Figures 1, 4 (.190.010) (.190.010) (.090.010) (.200.015) (.025.002) CCR06/CC06 7.37.25 7.37.25 2.29.25 5.08.38 .64.05 Figures 2, 3 (.290.010) (.290.010) (.090.010) (.200.015) (.025.002) CCR07/CC07 12.19.51 12.19.51 3.56.25 10.16.51 .64.05 Figure 2 (.480.020) (.480.020) (.140.010) (.400.020) (.025.002) CCR08/CC08 12.19.51 12.19.51 6.1.25 10.16.51 .64.05 Figure 2 (.480.020) (.480.020) (.240.010) (.400.020) (.025.002) CCR09/CC09 4.83.25 4.83.25 2.29.25 2.54.38 .64.05 Figure 2 (.190.010) (.190.010) (.090.010) (.100.015) (.025.002) 67MIL-PRF-20/Radial Leads MILITARY PART NUMBER IDENTIFICATION Military Type Capacitance Capacitance Military Type Capacitance Capacitance Designation (pF) Tolerance WVDC Designation (pF) Tolerance WVDC CC05-CCR05, CC09-CCR09 CC05-CCR05, CC09-CCR09 (cont) CCR05CX1R0 1.0 B, C 200 CCR05CG222 2,200 F, G, J 50 CCR05CX1R1 1.1 B, C 200 CCR05CG242 2,400 F, G, J 50 CCR05CX1R2 1.2 B, C 200 CCR05CG272 2,700 F, G, J 50 CCR05CX1R3 1.3 B, C 200 CCR05CG302 3,000 F, G, J 50 CCR05CX1R5 1.5 B, C 200 CCR05CG332 3,300 F, G, J 50 CCR05CX1R6 1.6 B, C 200 CC06, CCR06 CCR05CX1R8 1.8 B, C 200 CCR05CX2R0 2.0 B, C 200 CCR06CG361 360 F, G, J 200 CCR05CK2R2 2.2 B, C 200 CCR06CG391 390 F, G, J 200 CCR05CK2R4 2.4 B, C 200 CCR06CG431 430 F, G, J 200 CCR05CK2R7 2.7 B, C, D 200 CCR06CG471 470 F, G, J 200 CCR05CK3R0 3.0 B, C, D 200 CCR06CG511 510 F, G, J 200 CCR05CK3R3 3.3 B, C, D 200 CCR06CG561 560 F, G, J 200 CCR05CK3R6 3.6 B, C, D 200 CCR06CG621 620 F, G, J 200 CCR05CK3R9 3.9 B, C, D 200 CCR06CG681 680 F, G, J 200 CCR05CJ4R3 4.3 B, C, D 200 CCR06CG751 750 F, G, J 200 CCR05CJ4R7 4.7 B, C, D 200 CCR06CG821 820 F, G, J 200 CCR05CJ5R1 5.1 B, C, D 200 CCR06CG911 910 F, G, J 200 CCR05CJ5R6 5.6 B, C, D 200 CCR06CG102 1,000 F, G, J 200 CCR05CJ6R2 6.2 B, C, D 200 CCR06CG112 1,100 F, G, J 200 CCR05CJ6R8 6.8 B, C, D 200 CCR06CG122 1,200 F, G, J 200 CCR05CJ7R5 7.5 B, C, D 200 CCR06CG132 1,300 F, G, J 200 CCR05CH8R2 8.2 B, C, D 200 CCR06CG152 1,500 F, G, J 200 CCR05CH9R1 9.1 B, C, D 200 CCR06CG162 1,600 F, G, J 200 CCR05CH100 10 F, G, J 200 CCR06CG182 1,800 F, G, J 200 CCR05CH110 11 F, G, J 200 CCR06CG202 2,000 F, G, J 100 CCR05CH120 12 F, G, J 200 CCR06CG222 2,200 F, G, J 100 CCR05CH130 13 F, G, J 200 CCR05CH150 15 F, G, J 200 CCR06CG242 2,400 F, G, J 100 CCR06CG272 2,700 F, G, J 100 CCR05CH160 16 F, G, J 200 CCR06CG302 3,000 F, G, J 100 CCR05CH180 18 F, G, J 200 CCR06CG332 3,300 F, G, J 100 CCR05CG200 20 F, G, J 200 CCR06CG362 3,600 F, G, J 100 CCR05CG220 22 F, G, J 200 CCR05CG240 24 F, G, J 200 CCR06CG392 3,900 F, G, J 100 CCR06CG432 4,300 F, G, J 100 CCR05CG270 27 F, G, J 200 CCR06CG472 4,700 F, G, J 100 CCR05CG300 30 F, G, J 200 CCR06CG512 5,100 F, G, J, K 50 CCR05CG330 33 F, G, J 200 CCR06CG562 5,600 F, G, J, K 50 CCR05CG360 36 F, G, J 200 CCR05CG390 39 F, G, J 200 CCR06CG622 6,200 F, G, J, K 50 CCR06CG682 6,800 F, G, J, K 50 CCR05CG430 43 F, G, J 200 CCR06CG752 7,500 F, G, J, K 50 CCR05CG470 47 F, G, J 200 CCR06CG822 8,200 F, G, J, K 50 CCR05CG510 51 F, G, J 200 CCR06CG912 9,100 F, G, J, K 50 CCR05CG560 56 F, G, J 200 CCR05CG620 62 F, G, J 200 CCR06CG103 10,000 F, G, J, K 50 CCR05CG680 68 F, G, J 200 CCR06CG123 12,000 F, G, J, K 50 CCR06CG153 15,000 F, G, J, K 50 CCR05CG750 75 F, G, J 200 CCR06CG183 18,000 F, G, J, K 50 CCR05CG820 82 F, G, J 200 CCR05CG910 91 F, G, J 200 CC07, CCR07 CCR05CG101 100 F, G, J 200 CCR05CG111 110 F, G, J 200 CCR07CG222 2,200 F, G, J, K 200 CCR07CG272 2,700 F, G, J, K 200 CCR05CG121 120 F, G, J 200 CCR07CG332 3,300 F, G, J, K 200 CCR05CG131 130 F, G, J 200 CCR07CG392 3,900 F, G, J, K 200 CCR05CG151 150 F, G, J 200 CCR07CG472 4,700 F, G, J, K 200 CCR05CG161 160 F, G, J 200 CCR05CG181 180 F, G, J 200 CCR07CG562 5,600 F, G, J, K 100 CCR07CG682 6,800 F, G, J, K 100 CCR05CG201 200 F, G, J 200 CCR07CG822 8,200 F, G, J, K 100 CCR05CG221 220 F, G, J 200 CCR05CG241 240 F, G, J 200 CCR07CG103 10,000 F, G, J, K 100 CCR07CG123 12,000 F, G, J, K 100 CCR05CG271 270 F, G, J 200 CCR05CG301 300 F, G, J 200 CCR07CG153 15,000 F, G, J, K 50 CCR07CG183 18,000 F, G, J, K 50 CCR05CG331 330 F, G, J 200 CCR05CG361 360 F, G, J 100 CCR07CG223 22,000 F, G, J, K 50 CCR05CG391 390 F, G, J 100 CCR07CG273 27,000 F, G, J, K 50 CCR07CG333 33,000 F, G, J, K 50 CCR05CG431 430 F, G, J 100 CCR05CG471 470 F, G, J 100 CCR07CG393 39,000 F, G, J, K 50 CCR05CG511 510 F, G, J 100 CCR07CG473 47,000 F, G, J, K 50 CCR05CG561 560 F, G, J 100 CCR07CG563 56,000 F, G, J, K 50 CCR05CG621 620 F, G, J 100 CCR07CG683 68,000 F, G, J, K 50 CCR05CG681 680 F, G, J 100 CCR07CG823 82,000 F, G, J, K 50 CCR05CG751 750 F, G, J 100 CCR07CG104 100,000 F, G, J, K 50 CCR05CG821 820 F, G, J 100 CC08, CCR08 CCR05CG911 910 F, G, J 100 CCR05CG102 1,000 F, G, J 100 CCR08CG392 3,900 G, J, K 200 CCR05CG112 1,100 F, G, J 100 CCR08CG472 4,700 G, J, K 200 CCR05CG122 1,200 F, G, J 100 CCR08CG153 15,000 G, J, K 100 CCR05CG132 1,300 F, G, J 100 CCR08CG183 18,000 G, J, K 100 CCR05CG152 1,500 F, G, J 100 CCR08CG563 56,000 G, J, K 50 CCR05CG162 1,600 F, G, J 100 CCR08CG683 68,000 G, J, K 50 CCR05CG182 1,800 F, G, J 100 CCR05CG202 2,000 F, G, J 50 Add appropriate failure rate level (M, P, R or S) Add appropriate cap. tolerance letter Add appropriate failure rate level (M, P, R or S) Add appropriate cap. tolerance letter Note: For marking information, see page 72. 68