SC40/60 Series 3 x 5 40W to 60W AC-DC Power Supplies Features u Low Cost u Single and Multiple Outputs u Wide Range AC Input u Low pro le u Global Safety Agency Compliance u Meets EN61000-4 (-2 to -6) u Industry standard footprint Key Market Segments & Applications Speci cations Model SCS40 SCT4x SCS60 SCD60 SCT6x Output Power Convection W 40 60 Output Power Forced Air W 55 - Main Output Adjustment V -5, +10% O/P 1 only -5, +10% Line and Load Regulation % Output 1: 2%, Output 2: 5% (7% on 24V models), Output 3: 5% Hold Up Time (typical) ms 20 20 Size (1) in 3 x 5 x 1 3 x 5 x 1.34 AC Input - 85-265 VAC, 47-63 Hz Ef ciency % Typically 70% full load at nominal AC Line Inrush Current Limiting A 36A typical 230VAC cold start Surge Immunity - EN61000-4 (-2 through -6) level 3 EMI - FCC Class B, EN55022 B Cross Regulation % 2% on output 1, 5% on outputs 2 & 3 (multiple outputs only) Ripple and Noise % 1% peak to peak Overcurrent Protection - Short circuit protection, automatic recovery Overvoltage Protection - Output 1 only, <135% Cooling - When speci ed with forced air cooling, ow is 300 LFM (1.5m/s) Operating Temp. Range (2) - 0 to +70C (Derate linearly to 50% load from 50-70C) Storage Temperature C -20 to +85C Safety Agency Approval - UL60950-1, CSA60950-1, IEC/EN60950-1, CE Mark Warranty yr 1 year (1) Height is speci ed as maximum component height Note: See Installation Manual for full details, test methods of parameters and application notes (2) -40C startup, contact factory for details. 1-800-526-2324 www.us.tdk-lambda.com/lp/ 91 Disclaimer: us.tdk-lambda.com/lp/legal.htmSC40/60 Series Options Outline Drawing O/P Min Convec. Forced Peak Model (V) Load(A) (A) Air(A) Load(A)** Single Output SCS4024 V1 24.0 - 1.6 2.3 2.5 SCS4048 V1 48.0 - 0.9 1.2 1.3 SCS6012 V1 12.0 - 5.0 6.7 7.5 SCS6024 V1 24.0 - 2.5 3.3 3.8 SCS6028 V1 28.0 - 2.1 2.9 3.2 SCS6048 V1 48.0 - 1.3 1.7 1.9 Dual Output SCD601515 V1 15.0 0.2 2.2 2.9 - V2 -15.0 0.2 1.8 2.4 - Triple Output SCT42 V1 5.0 0.4 4.0 5.0 7.0 V2 12.0 0.2 2.0 2.5 4.0 V3 -12.0 - 0.5 0.7 1.0 SCT45 V1 5.0 0.4 4.0 5.0 7.0 V2 15.0 0.2 2.0 2.5 3.0 V3 -15.0 - 0.5 0.7 1.0 SCT48/R* V1 5.0 0.4 4.0 5.0 6.0 V2 24.0 0.1 1.0 1.5 2.0 V3 -5.0 - 0.5 0.7 1.0 SCT62 V1 5.0 0.7 7.0 - 10.0 V2 12.0 0.3 3.0 - 6.0 V3 -12.0 - 0.7 - 1.5 SCT63 V1 5.0 0.7 7.0 - 10.0 V2 15.0 0.3 2.8 - 4.0 V3 -15.0 - 0.7 - 1.5 SCT65 V1 5.0 0.7 7.0 - 10.0 V2 24.0 0.1 1.5 - 3.0 V3 12.0 - 0.7 - 1.5 Model Selector Notes: For Additional Information, please visit * /R = Remote Sense. Leave unconnected when not used. us.tdk-lambda.com/lp/products/sc-series.htm ** <30s, 10% duty cycle, average power must not exceed maximum ratings. Other AC-DC Products ZP 20 to 60W 2 x 4, 1-3 outputs NV175 175W 3 x 5, 1-5 outputs ZWS 5 to 240W single output, universal input VSB, VSC, VSP 10 to 150W single output, 115VAC input SCS120PW 120W 3 x 5 single output CSS150 150W 3 x 5 single output 1-800-526-2324 www.us.tdk-lambda.com/lp/ 92 Revision B4: Jan 2012