UDS1100-IAP Industrial Device Server In minutes, securely connect factory floor devices to enterprise systems Access, monitor and control equipment over Ethernet Replace dedicated PCs and/or modem lines with fast and reliable Ethernet networking Supports RS-232, RS-422 and RS-485 communications Includes Modbus TCP, ASCII, RTU and DF1 protocols 15KV serial ESD protection Wide -40 70C operating temperature range Environmentally-friendly RoHS and WEEE-compliant Remotely Monitor, Manage and Control Industrial Equipment Over the Net The UDS1100-IAP is a rugged and powerful tool Built-in Web Server The built-in web server enables users to access and which enables users to connect, manage and control configure the UDS1100-IAP from a standard web browser. Web pages enabling the UDS1100-IAP to be customized just about any piece of industrial equipment from for unique applications can be built using Lantronix development tools. On-board Flash memory provides room virtually anywhere over Ethernet or the Internet. for future system software upgrades and maintenance-free, nonvolatile web page storage. This single-port Device Server is a quick, simple and Easy to Set Up and Use inexpensive way to bring the advantages of real-time The UDS1100-IAP can be set up locally through its serial port, or remotely using Telnet or a web browser. The or on-demand information access. included DeviceInstaller Windows-based configuration software simplifies setup and provides an easy way to: Assign IP & other network specific addresses Standards Based Communications Load custom web pages Using an open Ethernet architecture as a standard provides Enable web-based configuration of the Device Server the flexibility for equipment to communicate to virtually any Ping or query the attached device(s) over the network type of industrial device. View specific device data files When used in conjunction with an OPC server, most Upgrade firmware Windows based HMI, SCADA and PC-based control Simplify process of installing industrial protocols applications have full access to information in the industrial equipment networked by the UDS1100-IAP. Complete with an auto MDI/MDIX Ethernet interface, the UDS1100-IAP is a powerful device communication solution Extending Communications Across the Globe thats perfect for your most demanding industrial applications. Our approach to network-enabling devices is transparent to your attached equipment and software so you wont need Modem Replacement to change the way you work. Using a method called serial In modem emulation mode, the UDS is used to replace dial- tunneling, the UDS1100-IAP encapsulates serial data into up modems. The unit accepts modem AT commands on the packets and transports it over Ethernet. Serial tunneling can serial port. It then establishes a network connection to the be done in multiple ways: end device, leveraging network connections and bandwidth to eliminate dedicated modems and phone lines. Using Lantronix supplied Com Port Redirector software, Windows device applications not RoHS-compliant, the UDS1100-IAP meets Directive 2002/95/EC designed for network communications are on the restriction of the use of certain hazardous re-directed to communicate to devices connected substances in electrical and electronic equipment. to the UDS1100-IAP. Connecting two UDS1100-IAP Device Servers If youre looking for a transparent, cost-effective, configured to automatically talk to each other over and scalable means to network-enable your industrial the network creates virtual serial connections that automation equipment, look no further than the can extend serial communications across a facility or around the world. UDS1100-IAP. Industrial Device Server UDS1100-IAPUDS1100-IAP Example Configurations SERIAL TUNNELING CONFIGURATION Ethernet A UDS1100-IAP Device Servers Features and Specifications Serial Interface Interface: Software-selectable RS232, RS422 or RS485 (2 and 4 wire support) Connectors: 1 DB25F DCE serial port Programmable Logic Controller Data Rates: Software-selectable baud rate from 300 to 230 KBaud (PLC) Personal Computer (PC) Characters: 7 or 8 data bits Parity: odd, even, none Stop Bits: 1 or 2 Control Signals: CTS/RTS (Hardware) DIRECT TCP/IP Flow Control: XON/XOFF (Software) OR REDIRECTOR CONFIGURATION Network Interface Ethernet B Interface: 10Base-T/100Base-TX Ethernet port Software selectable Ethernet speed 10/100/Auto Software selectable Half/Full/Auto duplex Connector: RJ45 Standards: ARP,UDP,TCP, ICMP,Telnet,TFTP, AutoIP,DHCP,HTTP, SNMP, TCP,UDP, and Telnet,TFTP Indicators (LED) Personal Computer (PC) Power, 10/100 Link/Activity (green), 100/100 Link/Activity(green), Diagnostics (red), Status (green) Programmable Logic Controller Processor (PLC) CPU: Lantronix DSTNI-EX 48 MHz clock Memory: 256 KB zero wait state SRAM, 2 MB Flash Emissions Management FCC Part 15 Subpart B Class A Radiated Emissions 30MHz 1000MHz Lantronix DeviceInstaller GUI, Serial login,SNMP, ICES-003 Issue 4 February 2004 Class A Radiated Emissions 30MHz 1000MHz Telnet login,HTTP AS/NZS CISPR 22: 2004 Class A Radiated Emissions 30MHz 1000MHz Power EN55022: 1998 + A1: 2000 + A2: 2003 Class A Radiated Emissions 30MHz 1000MHz 9-30 VDC or 9-24 VAC on barrel connector (1.5 Watts maximum VCCI V-3/2005.04 Class A Radiated Emissions 30MHz 1000MHz consumption) EN61000-3-2: 2000 Class A Harmonic Current Emissions 9-30 VDC on DB25F serial interface EN61000-3-3: 1995 + A1: 2001 Fluctuations and Flicker 3.3vdc on serial interface Immunity Environmental EN55024: 1998 +A1: 2001 +A2: 2003 Operating: -40 to 70 C (41 to 158 F) IEC 61000-4-2: 1995 ESD 8KV Air Discharge (Direct), 4KV Contact Discharge (Direct/Indirect) Storage: -40 to 85 C (-40 to 185 F) IEC 61000-4-3: 1995 Radiated Immunity 3.0V/m, 1KHz AM Sine Wave at 80% Packaging IEC 61000-4-4: 1995 EFT/Burst 1.0KV Power Lines, 0.5KV I/O Lines Material: Metal enclosure with integrated wall mounts IEC 61000-4-5: 1995 Surge Immunity 1.0KV Common Mode, 1.0 KV Differential Mode optional 35 mm DIN-rail mount available IEC 61000-4-6: 1996 Conducted Immunity 3.0 Vrms, 80% AM Modulated (1KHz) Dimensions (LxWxH): 9.0 x 6.4 x 2.3 cm (3.5 x 2.5 x 0.9 in) IEC 61000-4-8: 1993 Magnetic Field Immunity 50Hz 1.0 Arms/m Weight: 0.20 kg (0.45 lb) IEC 61000-4-11: 1994 Voltage Dips and Interrupts (>95%,0.5 periods), (30%,25 periods), (>95%,250 periods) IP Rating: 30 Isolation Agency Approvals Designed with protection against transients and ESD for use under harsh environments. UL, CSA, FCC, CE,TUV, CTick,VCCI Serial Port: 15 KV ESD protection on RS232 and RS422/485 transceivers Power Input: Up to non-repeated 600 W 10/100 usec pulse protection against transient over voltages Warranty Ethernet Port: 1500 VAC isolation shielded with shield connected to chassis ground for signal integrity 2-year limited warranty and ESD protection Shipping Dimensions Dimensions (LxWxH): 242 x 191 x 115 mm (9.5 x 7.5 x 4.5 in) Ordering Information Weight: 1.5 kg (3.0 lbs) Part Number Description UD1100IA2-01 UDS1100-IAP Device Server, 100-240 VAC International Included Software power supply with regional adapters, includes 500-163 Windows 98/ME/NT/2000/XP-based DeviceInstaller cable and ACDIN1001-01 Din rail mount configuration software, Com Port Redirectorsoftware and related utilities Accessories 500-163 DB25M to DB9F serial cable (included) ACDIN1001-01 Optional DIN-rail mount (included) 500-171-R DB25M to RS485 and power input screw terminal adapter (order separately) 15353 Barranca Parkway Irvine CA 92618 USA Tel: 800.422.7055 Fax: 949.450.7232 www.lantronix.com 2006, Lantronix, Inc. Lantronix is a registered trademark, and Device Server, DeviceInstaller and Com Port Redirector are trademarks of Lantronix, Inc. All other trademarks are the property of their respective owners. Specifications subject to change without notice. All rights reserved. 910-502 09/06 DGS2500 UDS1100-IAP Device Server Industrial Device Server UDS1100-IAP