EL-GFX-DTC Dual Channel K, J & T-type Thermocouple Data Logger with Graphic Screen Compatible with K, J and T-type thermocouples with miniature thermocouple plug connections Stores over 250,000 readings EasyLog software available as a free download Logging rates between 2 seconds and 1 hour Supplied with a pair of 1.5m K-type thermocouples with 0 to 200C (32 to 392F) measurement range On-screen graphing, and menu options to start, stop, review and restart the logger in the field Immediate, delayed, push-button or temperature triggered start mode This standalone data logger measures and stores more than 250,000 temperature readings from two K, J or T-type thermocouple probes at a resolution of 0.1C (0.2F). It comes supplied with two K-type thermocouples capable of measuring from 0 to 200C (32 to 392F). Your application will determine which probe is most suitable based on temperature range, accuracy, form and price. A wide variety of alternative thermocouples are available. Please call Lascar for vendor recommendations. The user can easily set up the logger and view downloaded data by plugging the data logger into a PCs USB port and using the free EasyLog software. Data can then be graphed, printed and exported to other applications for detailed analysis. The data logger features a high contrast dot-matrix LCD and three buttons to navigate through an on-screen menu. This menu provides the user with access to real-time trend analysis, data summaries and the ability to start, stop and restart the data logger without the need to connect the data logger to the host PC. Users can reset the maximum / minimum reading using the on-screen menu this introduces an event marker into the data which can later be viewed in the graphing software (Mark Events option) and the data file aer doft wnload. The data logger is supplied complete with two lithium metal baeries, which ctt an typically allow logging for up to 1 year. SPECIFICATIONS ACCESSORIES Probe measurement range BAT 3V6 1/2AA Replacement baertt y K-type (supplied) 0 to 200C (32 to 392F) (2 required) K-type -200 to 1350C (-328 to 2462F) EL-P-TC-K Replacement K-type J-type -200 to 1190C (-328 to 2174F) thermocouple probe T-type -200 to 390C (-328 to 734F) Accuracy (logger error) 1.5C (2.7F) INCLUDED IN THE BOX Internal resolution 0.1C (0.2F) x2 BAT 3V6 1/2AA Baertt y Logging rate User selectable between 2 seconds & 1 hour CABLE USB A-MICRO B USB cable Operating temperature range -10 to +40C (+14 to +104F) (data logger only) Baertt y Life 1 year (at 25C, 1 minute logging rate, LCD off) x2 EL-P-TC-K K-type thermocouple probe Readings 252,928 EL-GFX WALL BRACKET Magnetic mounting bracket Dimensions 102 x 48.5 x 30.5mm (4.01 x 1.90 x 1.20) CALIBRATION CERTIFICATES NOW AVAILABLE Lascar now offers a Traceable Calibration Certificate Service on Temperature Data Loggers. Using reference equipment which has been calibrated by a UKAS/NIST accredited laboratory and using apparatus traceable to national or international standards. For more information please see www.lascarelectronics.com. www.lascarelectronics.com/data-loggers Issue 17 02/2021 Page 1 of 3EL-GFX-DTC Dual Channel K, J & T-type Thermocouple Data Logger with Graphic Screen EASYLOG SOFTWARE Lascars EasyLog control software is available as a free download from www.easylogusb.com. Easy to install and use, the control software is compatible with 32-bit and 64-bit versions of Windows 7, 8 and 10. The software is used to set up the logger, download, graph and annotate data or export in Excel, PDF and jpeg formats. The software allows the following parameters to be configured: Logger name Measurement parameter (C or F) Logging rate (selectable between 1 second and 12 hours) High and low alarms Immediate and delayed logging start Download the latest version of the software free of charge from www.easylogusb.com MENU BUTTON FUNCTIONS AND LCD SCREEN INDICATION DISPLAY DATA START LOGGER Data can be displayed on screen in Loggers can be started immediately tabular or graphical format on a button press, delayed to a You can switch between these views by specific time or delayed to specific pressing the / buttons at temperature reading the bottom-left of your screen ON-SCREEN ICONS STOP/START LOGGING & MUTE ALARM By pressing the button, you can stop your logger, or view logger settings. If you have already stopped logging, this option will change to Start Logging. When the EasyLog cube is High/Low Alarm indicators This icon indicates that your The audible alarm can be muted from shown in the top-left corner are displayed at the top of baett ry is low and will need this menu if enabled your logger is logging your screen to be replaced soon SUMMARY DATA LOCKED MODE Summary screen displays max/min When in locked mode - an option log and last log. Reset function clears during PC set-up - the logger can only summary if required be stopped and re-started using a PC These screens can be reached by loaded with the units configuration software pressing the button POP-UP MESSAGES LOGGER SETTINGS A message will overlay the screen - if To view a summary of the loggers there is an issue - the next time a settings press the button, then button is pressed, e.g. if the logger is click Logger Settings running low on memory Please note that screens may vary slightly depending on model. www.lascarelectronics.com/data-loggers Issue 17 02/2021 Page 2 of 3