X-On Electronics has gained recognition as a prominent supplier of 0441004.WRA Surface Mount Fuses across the USA, India, Europe, Australia, and various other global locations. 0441004.WRA Surface Mount Fuses are a product manufactured by Littelfuse. We provide cost-effective solutions for Surface Mount Fuses, ensuring timely deliveries around the world.
We are delighted to provide the 0441004.WRA from our Surface Mount Fuses category, at competitive rates not only in the United States, Australia, and India, but also across Europe and beyond. A long established and extensive electronic component distribution network has enhanced our global reach and dependability, ensuring cost savings through prompt deliveries worldwide. Client satisfaction is at the heart of our business, where every component counts and every customer matters. Our technical service team is ready to assist you. From product selection to after-sales support, we strive to deliver a seamless and satisfying experience. Are you ready to experience the best in electronic component distribution? Contact X-ON Electronics today and discover why X-On are a preferred choice for the 0441004.WRA and other electronic components in the Surface Mount Fuses category and beyond.
Surface Mount Fuses Ceramic Fuse > 441A Series 2 RoHS Pb 441A Series 0603 High I t Fuse Description The 441A series AECQ-Compliant fuses are specifically tested to cater to secondary circuit protection needs of compact auto-electronics application. The general design ensures excellent temperature stability and performance reliability. This high It fuse series is designed to have ultra high inrush current withstand capability to avoid nuisance fuse open. Features Operating Temperature Suitable for both leaded Agency Approvals from -55C to 150C and lead-free reflow/wave soldering 100% Lead-free, Halogen- AGENCY AGENCY FILE NUMBER AMPERE RANGE 2 Free and RoHS compliant Ultra high I t values E10480 2A - 6A Meets Littelfuses automotive qualifications* 29862 2A - 6A * - Largely based on Littelfuse internal AEC-Q200 test plan. Electrical Characteristics Applications Li-ion Battery TFT Display % of Ampere Ampere Rating Opening Time at 25C Rating LED Head Lights Battery Management 100% 2A - 6A 4 Hours Minimum System (BMS) Automotive Navigation 350% 2A - 6A 5 Seconds Maximum System Clusters Electrical Specifications by Item Agency Approvals Ampere Nominal Nominal Nominal Voltage Nominal Power Amp Max. Voltage Interrupting 2 Rating Resistance Melting I t Drop At Rated Dissipation At 1 Code Rating (V) Rating 2 2 3 4 (A) (Ohms) (A Sec.) Current (V) Rated Current (W) 2 002. 32 0.0302 0.3103 0.0551 0.110 X X 2.5 02.5 32 0.0200 0.5520 0.0534 0.134 X X 3 003. 32 0.0158 0.8165 0.0531 0.159 X X 3.5 03.5 32 50 A 32 VDC 0.0117 0.9438 0.0468 0.164 X X 4 004. 32 0.0097 1.2659 0.0475 0.190 X X 5 005. 32 0.0073 1.6287 0.0472 0.236 X X 6 006. 32 0.0056 2.6049 0.0464 0.278 X X Notes: Devices designed to carry out rated current for 4 hours minimum. It is recommended that 1. DC Interrupting Rating tested at rated voltage with time constant < 0.8 msecs. devices be operated continuously at no more than 80% rated current. See Temperature 2. Nominal Resistance measured with < 10% rated current. Re-rating Curvefor additional re-rating information. 3. Nominal Melting It measured at 1 msec. opening time. Devices designed to be mounted with marking code facing up. 4. Nominal Voltage Drop measured at rated current after temperature has stabilized. Additional Information Datasheet Resources Samples 2017 Littelfuse, Inc. Specifications are subject to change without notice. Application testing is strongly recommended.Specifications are subject to change without notice. Revised: 06/08/17Surface Mount Fuses Ceramic Fuse > 441A Series Temperature Re-rating Curve Average Time Current Curves 100 140 120 10 100 80 1 60 40 -65 -45 -25 -5 15 35 55 75 95 115 135 155 0.1 TEMPERATURE (C) Note: 1. Re-rating depicted in this curve is in addition to the standard re-rating of 20% for 0.01 continuous operation. For continuous operation at 75 degrees celsius, the fuse should be rerated as follows: I = (0.80)(0.85)I = (0.68)I RAT RAT 0.001 1 10 100 CURRENT IN AMPERES Soldering Parameters t P Reflow Condition Pb free assembly T P Critical Zone Ramp-up T to T L P - Temperature Min (T ) 150C s(min) T L Pre Heat - Temperature Max (T ) 200C t s(max) L T S(max) - Time (Min to Max) (t ) 60 180 seconds s Ramp-down Average Ramp-up Rate (Liquidus Temp Preheat 3C/second max. T (T ) to peak) S(min) L t S T to T - Ramp-up Rate 5C/second max. S(max) L - Temperature (T ) (Liquidus) 217C L 25 Reflow time to peak temperature - Temperature (t ) 60 150 seconds Time L (t 25C to peak) +0/-5 Peak Temperature (T ) 260 C P Time within 5C of actual peak 10 30 seconds Temperature (t ) p Ramp-down Rate 6C/second max. Time 25C to peak Temperature (T ) 8 minutes max. P Do not exceed 260C Wave Soldering 260C, 10 seconds max. 2017 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 06/08/17 PERCENT OF RATING TIME IN SECONDS 2A 2.5A 3A 3.5A 4A 5A 6A Temperature
One such essential component is the DSPIC33EP64GP502-ISP from Microchip Technology, a part of their Digital Signal Processors & Controllers (DSP, DSC) lineup. This article explores why Xon Electronic stands out as the best supplier for this p
Difference Between Fuses and Breakers: A Comprehensive Guide Difference Between Fuses and Breakers: A Comprehensive Guide Aug 13, 2024 Discover the key differences between fuses and circuit breakers in this comprehensive guide. Learn about their types, working principles, advantages, and disadvantages. Understand how to choose the right overcurrent protection device for your needs, whether for residential, commercial, or industria
Calling all new customers! Register now with Xon Electronics and save 5%, up to 50$, on your first order! Don't miss out – this offer won't last forever!
Discount Code : XONFIRSTUSER