PRODUCT: PESD0402-240 ESD Protector DOCUMENT: SCD28721 Overvoltage Protection Device REV LETTER: C REV DATE: JULY 26, 2016 PAGE NO.: 1 OF 9 Specification Status: RELEASED BENEFITS ESD protection for high frequency applications (HDMI 1.3) Smaller form factor for board space savings Helps protect electronic circuits against damage from electrostatic discharge (ESD) events Assists equipment to pass IEC 61000-4-2, level 4 testing FEATURES 0.25 pF (typ) Capacitance Low leakage current Low clamping voltage Fast response time (<1ns) Capable of withstanding numerous ESD strikes Compatible with standard reflow installation procedures Thick film technology Bi-directional protection APPLICATIONS HDMI 1.3 interface LCD, HDTV Cellular phones Antennas (cell phones, GPS) Portable video devices (PDA, DSC, Bluetooth) Printer ports High speed Ethernet USB 2.0 and IEEE 1394 interfaces DVI interface CAUTION: This device should not be used in Power Bus applications MATERIALS INFORMATION RoHS Compliant ELV Compliant Halogen Free* Lead Free HF 2016 Littelfuse, Inc. littelfuse.com Specifications are subject to change without notice. Revised July 26, 2016 PRODUCT: PESD0402-240 ESD Protector DOCUMENT: SCD28721 Overvoltage Protection Device REV LETTER: C REV DATE: JULY 26, 2016 PAGE NO.: 2 OF 9 PART NUMBERING PESD 0402 - 240 Series Operating Voltage Designator 0 24 x 10 = 24V DC EIA Size * Halogen Free refers to: Br900ppm, Cl900ppm, Br+Cl1500ppm TYPICAL DEVICE RATINGS AND CHARACTERISTICS Continuous Typical Typical TLP Typical Typical Max 2 Max TLP Clamping Capacitance Leakage Leakage 1 Operating Trigger Voltage 1 MHz, Current Current 1 Voltage Voltage after 30ns 1Vrms 24VDC 24VDC Symbol VDC VT(TLP) VC(TLP 30) Cp IL(Typ) IL(MAX) Unit V V V pF A A Value 24 250 40 0.25 <0.01 10.0 Note 1: TLP test method at 1000V (refer to FIG. 5 on page 5) Note 2: Typical capacitance 0V and 24V bias GENERAL CHARACTERISTICS Operating temperature: -55C to +125C Storage temperature: -55C to +125C ESD voltage capability (tested per IEC 61000-4-2) o Contact discharge mode: 8kV (typ), 15kV (max) o Air discharge mode: 15kV (typ), 25kV (max) 1 pulse: per customer request ESD pulse withstand: Typically 100 pulses (tested per IEC 61000-4-2, level 4, and contact method) Environmental Specifications Solvent Bias Humidity Bias Heat Bias Low Solder Mechanical Thermal Shock Solderability Vibration Resistan Test Test Temp Test Heat Shock ce o 85 C 10 to 50Hz, 60s 1500G, o o o o o o -55 C to 125 C 125 C -55 C 250 C +/- 5 C IPA Test 85% RH cycle, 2hrs 0.5ms, X- o 30min dwell V (max) V (max) 3s +/- 1s 260 C,10s ultrasonic DC DC Conditions V (max) each in X-Y-Z Y-Z axis DC 1000 cycles 1000 hours 1000 hours 300s 1000 hours axis 3 times 2016 Littelfuse, Inc. littelfuse.com Specifications are subject to change without notice. Revised July 26, 2016