TVS Diode Arrays (SPA Diodes) General Purpose ESD Protection-SP1012 Series RoHS Pb GREEN SP1012 Series 6.5pF, 15kV Bidirectional TVS Array Description The miniature 5 channel bidirectional TVS array provides protection for data lines that may experience destructive electrostatic discharges (ESD). These robust diodes can safely absorb repetitive ESD strikes at the maximum level specified in the IEC 61000-4-2 international standard without performance degradation. The bidirectional configuration provides symmetrical ESD protection for data lines when AC signals are present. Functional Block Diagram Features RoHS compliant, Highest density TVS array 12 3 Halogen-free and lead- available today free 5 channels of protection ESD, IEC 61000-4-2, in a 0.94x0.61mm 15kV contact, 30kV air footprint (i.e. a discrete 0402) EFT, IEC 61000-4-4,40A (5/50ns) Lightning protection, IEC 61000-4-5 2nd Edition, 3.0A (t =8/20s) p 45*6 *Any pin can be used as GND. Pinout Applications Smart Phones Mobile Phones Wearable Technology 12 3 Additional Information Die edge 45 6 Samples Datasheet Resources Life Support Note: Not Intended for Use in Life Support or Life Saving Applications The products shown herein are not designed for use in life sustaining or life saving applications unless otherwise expressly indicated. 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 12/13/16 TVS Diode Arrays (SPA Diodes) General Purpose ESD Protection-SP1012 Series Absolute Maximum Ratings Symbol Parameter Value Units I Peak Current (t =8/20s) 3.0 A PP p T Operating Temperature -40 to 125 C OP T Storage Temperature -55 to 150 C STOR CAUTION: Stresses above those listed in Absolute Maximum Ratings may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Thermal Information Parameter Rating Units Storage Temperature Range -55 to 150 C Maximum Junction Temperature 150 C Maximum Lead Temperature (Soldering 20-40s) 260 C Electrical Characteristics (T =25C) OP Parameter Symbol Test Conditions Min Typ Max Units Reverse Standoff Voltage V 5.0 V RWM Reverse Breakdown V I =1mA 6.0 V BD R Voltage Leakage Current I V =5V 1.0 A R R I =1A, t =8/20s, Fwd 10.2 V PP p 1 Clamp Voltage V C I =3A, t =8/20s, Fwd 12.3 V PP p 2 Dynamic Resistance R TLP, t =100ns, I/O to GND 0.48 DYN p IEC 61000-4-2 (Contact Discharge) 15 kV 1 ESD Withstand Voltage V ESD IEC 61000-4-2 (Air Discharge) 30 kV 1 Diode Capacitance C Reverse Bias=0V (I/O to GND) 6.5 pF D Note: 1 Parameter is guaranteed by design and/or device characterization. 2 Transmission Line Pulse (TLP) with 100ns width and 200ps rise time. Clamping Voltage vs. I Capacitance vs. Reverse Bias PP 14 7.0 12 6.0 10 5.0 8 4.0 6 3.0 4 2.0 2 1.0 0.0 0 0.01.0 2.03.0 4.05.0 1.01.5 2.02.5 3.0 Voltage (V) Peak Pulse Current-I (A) PP 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 12/13/16 Clamp Voltage (V ) C Capacitance (pF)