REMOTE PROGRAMMING GENERAL PURPOSE POWER SUPPLY LABORATORY GRADE POWER SUPPLY SPS - 9402 M anson 160W Constant Power (Auto-Range) Switching Mode Power Supply M anson High Current Switching Mode Power Supply SSP - 8160 / 8162 Description A conventional power supply has a set max. voltage and a set max current such that all the operating V & A must fall inside these limits. For example a 20V max. and 8A max. power supply with 160W can only supply voltage and current within the above two limits of V & I. If you want to have 40V with smaller current (4A) or 10A with lower voltage (14V) you need to buy another power supply. This completely new designed laboratory grade power supply differs from the conventional power supply by calculating and changing the voltage and current limit points according to the available max. power. So the max limits of the voltage and current are changeable according to the rated power. In the above example, with the constant-power supply can give 16V max. with 10A max. or 42V with 4A max and etc. The combinations of max. V and I are greatly increased and so is the range of operational limits as shown in the hyperbolic graph of max. power voltage- ampere. The key benefit is clear, it saves money as one constant-power power supply can do the work of a few conventional power supplies. 42V, 4A Traditional Power Supply Features V 32V, 5A Traditional Power Supply Saves money and space as one power supply covers V, A limits of few power supplies. 16V, 10A Traditional Power Supply Adjustable upper voltage and current output levels to ensure safe 42 operation SSP-8160 Constant Power Supply 3 user presets of frequently used V and A outputs Description 32 Features 4 digit display of voltage and current Analogue Remote Control V, I & On-Off Ramp, Step, DC output with 3 presets The series of HIGH POWER SWITCHING MODE DC 20A current output 16 Remote Programming with provided software & drivers via USB port REGULATED POWER SUPPLIES provide high current 20 Floating Ground Design Output on-off switch and control panel lock button for safer operation Over Temperature, Over Current, Over Voltage and Short Circuit Amps output in a lightweight and compact size case. Adjustable output voltages 3V to 30V A Protection They are suitable for a wide range of uses, such as 13.8V Lock Control 0 4 5 10 Universal Input 90 - 264Vac, 50 - 60Hz Light weight and small size radio equipment, and are ideal for high power car stereo work. In addition to variable output from 3 to Over temperature protection Specifications 30VDC, a fixed 13.8VDC can be selected. Overload, Constant Current Protection prevents overloading Over temperature, and Over voltage protection are Over voltage protection at 33-35V Models SSP - 8160 SSP - 8162 Input Voltage Range 100 - 240VAC standard. Variable speed thermally controlled fan No Load Input Current at 230VAC / 100VAC 0.25A High RFI stability Full Load Input Current at 230VAC / 100VAC 1.0A / 2 .3A Power factor correction >0.95 AC Input Frequency 45 - 65Hz~ Housing are available in Pantone warm grey 1C Efficiency (230VAC / 100VAC) 85/83% 42V / 3.8A 86/84% 84V / 1.9A or Pantone 433C dark grey Power Factor 0.9 OUTPUT: Variable Output Voltage 0 - 42V 0 - 84V Variable Output Current 0 - 10A 0 - 5A Output Rated Power 160W Specifications Constant Voltage Characteristics: Load Regulation (10 - 100% rated current) 80mV 40mV Models SPS-9402 Line Regulation (90 - 264Vac) 10mV 10mV Variable Output Voltage 3 - 30VDC Ripple & Noise (peak-peak) 80mVp-p Fixed Output Voltage Mode 13.8VDC Ripple & Noise (r.m.s.) 8mV Constant Current Characteristics: Rated Output Current 20A Load Regulation (10 - 90% rated voltage) 50mA Ripple & Noise (r.m.s.) 5mV Line Regulation (90 - 264Vac) 10mA Load Regulation (0-100% load) 230mV Meter Accuracy Line Regulation (190-254VAC variation) 5mV Volt. Meter Accuracy (0.1% +5counts) 200-240VAC 50Hz~ (or on request) Curr. Meter Accuracy (0.1% +5counts) Input Voltage Resolution 0.02V 0.01A Efficiency 81% Output Setting Accuracy Voltage: (0.2% +5counts)V Current: (0.2% +5counts)A Meter Type LED Meter Transient Response Time (step: 50%-100% rated load) 1 .5ms Volt. Meter Range 3 digit Display Protection Adjustable upper voltage limit, Short circuit, Overload, Over temp., Adjustable upper current limit, Tracking OVP Curr. Meter Range 3 digit Display Output Terminals Safety Jack Front Panel Meter s Accuracy 1% +2 counts Additional Function 3 User defined V & I preset, Analogue Remote control V, I & output on-off Cooling System Variable speed thermally control fan (from 1/3 to full speed) Remote Programmable via USB to Computer Max. 20 preset of V & I, Max. preset cycle 999 Protection Devices Over Temperature, Short Circuit, Over Voltage Ramp Step Irregular Waveform Functions Yes Approvals CE EMC: EN 55011 LVD: EN 61010 Approvals CE EMC: EN 55011, 55022 LVD: EN 60950, 61558 Cooling Method Natural Convection Dimensions (WxHxD) 220x110x300mm 8.7x4.3x11.8inch Operating Temperature 0 - 40C Weight 2.5kgs 7.7lbs Dimensions (WxHxD) 200 x 95 x 245mm 7.9 x 3.7 x 9.5 inch Remarks Power factor correction >0.97 at optimal load Weight 2.3kg 5lb All values are based on the Standard ambient Temperature 25C and Pressure 0.1Mpa. All values are based on the Standard ambient Temperature 25C and Pressure 0.1Mpa. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICEX-ON Electronics Largest Supplier of Electrical and Electronic Components Click to view similar products for Bench Top Power Supplies category: Click to view products by Manson manufacturer: Other Similar products are found below : NL200 PR20 ZUPNC403 Z60-7-L-U ZUPNC402 GDM-8342 GPIB PSW 250-4.5 CPX200DP AX-8450A TPM-3003 HMP2020 HMP2030 HMP4040 1320 1350 UT804 1405 1410 1513 1514 1513 1550 1651A 1665 1666 1667 SDP-2405-000G 1673 1693 1694 MX100TP 1737 1739 1762 1788 TPM-3005 1900 1902B 9174B GDM-8245 GDM-8255A GDM-8341 PSW 160-7.2 PSW 30-36 PSW 80-13.5 Z10-20-LAN-U PSW 30-72 QL355P SII Z36-6-LAN-U HCS-3400-USB