30W Single Output Switching Power Supply ELN-30 series 7 , 9 . 67 / ,2& 6 . 6 . . . : ) % & / . , < - =- > /=/ > 7 % & /4* . % 7A % / 5/2 2 53- & . = 8> B ) 5 % % = *8 > = C *8 > LPS IP64 SPECIFICATION MODEL ELN-30-5 ELN-30-9 ELN-30-12 ELN-30-15 ELN-30-24 ELN-30-27 ELN-30-48 DC VOLTAGE 5V 9V 12V 15V 24V 27V 48V LED OPERATION VOLTAGE Note.7 3 ~ 5V 3 ~ 9V 3 ~ 12V 3 ~ 15V 3 ~ 24V 3 ~ 27V 3 ~ 48V RATED CURRENT 5A 3.4A 2.5A 2A 1.25A 1.12A 0.63A CURRENT RANGE 0 ~ 5A 0 ~ 3.4A 0 ~ 2.5A 0 ~ 2A 0 ~ 1.25A 0 ~ 1.12A 0 ~ 0.63A RATED POWER 25W 30.6W 30W 30W 30W 30.24W 30.24W RIPPLE & NOISE (max.) Note.2 80mVp-p 100mVp-p 120mVp-p 120mVp-p 150mVp-p 150mVp-p 250mVp-p 4.5 ~ 5.5V 8.7 ~ 10.5V 10.8 ~ 13.2V 13.5 ~ 16.5V 21.6 ~ 26.4V 24.3 ~ 29.7V 43.2 ~ 52.8V OUTPUT VOLTAGE ADJ. RANGE Can be adjusted by internal potentiometer SVR1 CURRENT ADJ. RANGE -25% ~ 3%. Can be adjusted by internal potentiometer SVR2 VOLTAGE TOLERANCE Note.3 5.0% LINE REGULATION 1.0% LOAD REGULATION 2.0% SETUP, RISE TIME Note.6 500ms, 80ms / 230VAC 1000ms, 80ms / 115VAC at full load HOLD UP TIME (Typ.) 50ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 75% 80% 82% 82% 85% 85% 87% INPUT AC CURRENT (Typ.) 0.75A/115VAC 0.48A/230VAC INRUSH CURRENT (Typ.) COLD START 55A(twidth=465s measured at 50% Ipeak) at 230VAC MAX. No. of PSUs on 16A 4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC CIRCUIT BREAKER LEAKAGE CURRENT 0.25mA / 240VAC 95 ~ 110% OVER CURRENT Protection type : Constant current limiting, recovers automatically after fault condition is removed PROTECTION 5.75 ~ 6.75V 11 ~ 13.5V 13.8 ~ 16V 17.5 ~ 21V 28 ~ 32V 31 ~ 36.4V 54 ~ 60V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover FUNCTION DIMMING CONTROL (OPTIONAL) 1.1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz WORKING TEMP. -20 ~ +60 (Refer toDerating Curv) 20 ~ 90% RH non-condensing WORKING HUMIDITY -40 ~ +80, 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL1310, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved design refer to TUV EN60950-1 WITHSTAND VOLTAGE I/P-O/P:3KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH EMC EMC EMISSION Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A EMC IMMUNITY MTBF 628.3Khrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 145*47*30mm (L*W*H) 0.26Kg 60pcs/16.6Kg/1.25CUFT PACKING NOTE % & ( % )% % & *+ , * - % . / & 0 & & & % & % % & 1 2 3 % & & 1 )1 3 - . & 4 5 & 6 77 & % & + % & & . . & & 53- 8 & & & 39 / & 0% & & & & File Name:ELN-30-SPEC 2015-05-2830W Single Output Switching Power Supply ELN-30 series Mechanical Specification Case No.964A Unit:mm 145 4.38 32020 2-R2.25 +V(Red) 32020 -V(Black) Tcase SVT 18AWG2C AC/L(Brown) 63.5 AC/N(Blue) SVT 18AWG2C 4.38 T case: Max. Case Temperature. OUTPUT(with optional dimming function) +V(Red) -V(Black) DIM+(Blue) UL2464 18AWG4C DIM-(White) Output voltage and current adjustment : remove the upper case and adjust through SVR1 & SVR2 shown in the diagram. SVR2 SVR1 SVR1 Output voltage adjustment SVR2 Output current adjustment Block Diagram fosc : 60KHz EMI FILTER RECTIFIERS POWER +V I/P & & SWITCHING -V RECTIFIERS FILTER DIM- DETECTION CIRCUIT PWM O.L.P. PWM or CONTROL O.C.P. 1.1~10V O.V.P. DIM+ Optional Dimming Control DeratingDerating Curve Curve Static Characteristics 100 100 90 80 80 70 60 60 40 50 20 40 -20 -15 -5 00415 30050 60 (HORIZONTAL) 90 100 125 135 145 155 165 175175 180 200 230 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (V) 60Hz File Name:ELN-30-SPEC 2015-05-28 LOADLOADLOAD (%) (%) (%) 9.83 47 15 LOADLOAD (%) (%) 9.83 30