100W Single Output with PFC Function EPP-100 series Users Manual Bauar t gep r u f t S i c h e r h e i t e g e l m a ge o d o s b e w a c g w w w . t u v . c o m ID 2000000000 UL62368-1 SPECIFICATION BS EN/EN62368-1 TPTC004 IEC62368-1 MODEL EPP-100-12 EPP-100-15 EPP-100-24 EPP-100-27 EPP-100-48 DC VOLTAGE 12V 15V 24V 27V 48V RATED CURRENT (convection) 6.3A 5A 3.2A 2.8A 1.6A RATED CURRENT (20CFM FAN) 8.5A 6.67A 4.2A 3.71A 2.1A CURRENT RANGE (convection) 0 ~ 6.3A 0 ~ 5A 0 ~ 3.2A 0 ~ 2.8A 0 ~ 1.6A CURRENT RANGE (20CFM FAN) 0 ~ 8.5A 0 ~ 6.67A 0 ~ 4.2A 0 ~ 3.71A 0 ~ 2.1A RATED POWER (convection) 75.6W 75W 76.8W 75.6W 76.8W RATED POWER (20CFM FAN) 102W 100.05W 100.8W 100.17W 100.8W OUTPUT RIPPLE & NOISE (max.) Note.2 120mVp-p 150mVp-p 240mVp-p 240mVp-p 300mVp-p VOLTAGE ADJ. RANGE 11.76 ~ 12.6V 14.7 ~ 15.75V 23.52 ~ 25.2V 26.46 ~ 28.35V 47.04 ~ 50.4V VOLTAGE TOLERANCE Note.3 2.0% 2.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load INPUT EFFICIENCY (Typ.) 91% 91% 92% 92.5% 92.5% AC CURRENT (Typ.) 1.4A/115VAC 0.7A/230VAC INRUSH CURRENT (Typ.) COLD START 70A/230VAC LEAKAGE CURRENT <2mA/240VAC 105 ~ 145% rated output power OVER LOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed 13.2 ~ 15.6V 16.83 ~ 19.5V 27.7 ~ 31.5V 30.2 ~ 34.05V 51.3 ~ 62.7V OVER VOLTAGE PROTECTION Protection type : Shut down o/p voltage, re-power on to recover 110 10 (RTH2),110 5 (TSW2) OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover AUXILIARY POWER(AUX) FUNCTION WORKING TEMP. -30 ~ +70 (Refer toDerating Curv) 20 ~ 90% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0 ~ 45) OPERATING ALTITUDE Note.6 2000 meters VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 500VDC / 25/ 70% RH EMC (Note 4) EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, heavy industry level, criteria A, EAC TP TC 020 MTBF 249.6Khrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 101.6*50.8*29mm (L*W*H) 0.2Kg 72pcs/15.4Kg/0.82CUFT PACKING NOTE 50mm 4-3.3 100W Single Output with PFC Function EPP-100 series Mechanical Specification Unit:mm 101.6 3.175 95.25 SVR1 CN105 Ground required 1 2 CN2 3 CN1 4 3 2 LED 1 FS1 T4A/250V Air flow direction FAN 20CFM 36 1 2 AC Input Connector (CN1) : JST B3P-VH or equivalent DC Output Connector (CN2) : JST B4P-VH or equivalent Pin No. Assignment Mating Housing Terminal Pin No. Assignment Mating Housing Terminal 1,2 DC COM 1 AC/L JST VHR JST SVH-21T-P1.1 JST VHR JST SVH-21T-P1.1 or equivalent or equivalent 2 No Pin 3,4 +V or equivalent or equivalent 3 AC/N FAN Connector(CN105) : JST B2B-PH-K-S or equivalent : Grounding required Pin No. Assignment Mating Housing Terminal 1 +12V JST PHR-2 JST SPH-002T-P0.5S or equivalent or equivalent 2 DC COM Block Diagram PFC fosc : 47KHz PWM fosc : 65KHz EMI FILTER RECTIFIERS PFC POWER +V & I/P & CIRCUIT SWITCHING -V RECTIFIER FILTER RECTIFIERS +12V AUX & FG FILTER DETECTION CIRCUIT O.T.P. O.L.P. CONTROL O.V.P. Output Derating Output Derating VS Input Voltage 100 100 With 20CFM Fan 90 75 80 Convection 60 70 60 45 50 25 40 (HORIZONTAL) -30 0 10 20 30 40 50 60 70 90 95 100 115 120 140 160 180 200 220 240 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (VAC) 60Hz File Name:EPP-100-SPEC 2021-09-15 LOAD (%) 50.8 3 max. 29 44.45 3.175 LOAD (%)