5W AC-DC Single Output Wall-mounted type G S05E-USB Features : Universal AC input / Full range No load power consumption <0.3W Compact size ErP step2 compliant 2 pole Euro plug Class I I power (without earth pin) Protections: Short circuit / Overload / Over voltage / Over temperature Pass LPS 100% full load burn-in test Fully enclosed plastic case Low cost, high reliability 2 years warranty SPECIFICATION MODEL NO. GS05E-USB DC VOLTAGE Note.2 5V RATED CURRENT 1.00A CURRENT RANGE 0 ~ 1.00A RATED POWER 5W OUTPUT RIPPLE & NOISE (max.) Note.3 80mVp-p VOLTAGE TOLERANCE Note.4 4.0% LINE REGULATION Note.5 1.0% LOAD REGULATION Note.6 4.0% SETUP, RISE, HOLD UP TIME 300ms, 20ms, 50ms at full load VOLTAGE RANGE 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) Note.7 71% INPUT AC CURRENT 0.15A / 100VAC INRUSH CURRENT (max.) 30A / 230VAC LEAKAGE CURRENT(max.) 0.25mA / 240VAC 105 ~ 135% rated output voltage power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed 105 ~ 200% rated output voltage, detect on main control IC PROTECTION OVER VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is removed U1 Tj 142 typically (U1) detect on main control IC OVER TEMPERATURE Protection type : Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. -20 ~ +50 (Refer toDerating curv) WORKING HUMIDITY 20% ~ 90% RH non-condensing -20 ~ +85, 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03% / (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:4242VDC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH EMC (Note. 8) Compliance to EN55022 Class B, EN61000-3-2,3 EMC EMISSION Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A EMC IMMUNITY MTBF 1100Khrs min. MIL-HDBK-217F(25) 41.54*30.5*20mm (L*W*H) OTHERS DIMENSION PACKING 32g 78pcs / 4.6Kg / CARTON USB Type A DC OUTPUT CONNECTOR NOTE 1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load. 3.Ripple & noise are measured at 20MHz by using a 12 twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 6.Load regulation is measured from 0% to 100% rated load 7.Efficiency is measured at 230VAC. 8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. File Name:GS05E-USB-SPEC 2013-11-145W AC-DC Single Output Wall-mounted type G S05E-USB Mechanical Specification Unit:mm 20 18.2 30.5 30.5 14 USB Type A -V 1 2 N.C 3 N.C 4 +V Derating Curve Static Characteristics 100 90 100 80 60 70 60 50 40 -20 10 20 30 40 50 90 95 100 110 120 140 160 180 200 220 240 264 INPUT VOLTAGE (VAC) 60Hz Ta () File Name:GS05E-USB-SPEC 2013-11-14 LOAD (%) 41.54 + - LOAD (%) 18.07