10 ~ 12W AC-DC Single Output Wall-mounted type
G S12U s e ri e s
Features :
Universal AC input / Full range
No load power consumption< 0.3W
ErP step2 compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 pole USA plug
Class power (without earth pin)
Protections: Short circuit / Overload / Over Voltage / Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / BSMI / CB / FCC
Pass LPS for full series
2 years warranty
SPECIFICATION
ORDER NO. GS12U05-P1I GS12U07-P1I GS12U09-P1I GS12U12-P1I GS12U15-P1I GS12U18-P1I GS12U24-P1I
SAFETY MODEL NO. GS12U05 GS12U07 GS12U09 GS12U12 GS12U15 GS12U18 GS12U24
DC VOLTAGE 5V 7.5V 9V 12V 15V 18V 24V
RATED CURRENT 2.0A 1.6A 1.33A 1.0A 0.8A 0.67A 0.5A
CURRENT RANGE 0 ~ 2.0A 0 ~ 1.6A 0 ~ 1.33A 0 ~ 1.0A 0 ~ 0.8A 0 ~ 0.67A 0 ~ 0.5A
RATED POWER 10W 12W 12W 12W 12W 12.06W 12W
OUTPUT
RIPPLE & NOISE (max.) Note.2 75mVp-p 90mVp-p 90mVp-p 120mVp-p 150mVp-p 180mVp-p 200mVp-p
VOLTAGE TOLERANCE Note.3 5.0% 4.0% 4.0% 3.0% 3.0% 3.0% 3.0%
LINE REGULATION Note.4 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0%
LOAD REGULATION Note.5 5.0% 4.0% 4.0% 3.0% 3.0% 2.0% 2.0%
SETUP, RISE, HOLD UP TIME 500ms, 20ms, 30ms/230VAC 500ms, 20ms, 10ms/115VAC at full load
VOLTAGE RANGE 90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 76% 78.5% 78.5% 78.5% 80% 80% 80.5%
INPUT
AC CURRENT 0.31A / 115VAC 0.16A / 230VAC
INRUSH CURRENT (max.) COLD START 25A / 115VAC 45A / 230VAC
LEAKAGE CURRENT (max.) 0.25mA / 240VAC
>105% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
115% ~ 135%
PROTECTION OVER VOLTAGE
Protection type : Clamp by zener diode
U1 Tj 140 typically (U1) Detect on main control IC
OVER TEMPERATURE Note.6
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP. 0 ~ +50 (Refer toDerating Curv)
WORKING HUMIDITY 20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
TEMP. COEFFICIENT
0.03% / (0 ~ 40 )
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1, CSA22.2, BSMI CNS14336 approved
SAFETY &
WITHSTAND VOLTAGE I/P-O/P:3KVAC
EMC I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
ISOLATION RESISTANCE
EMC EMISSION Compliance to FCC PART 15 / CISPR22 class B, CNS13438 class B
MTBF 1414.6Khrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION 65*47*26.5mm (L*W*H)
0.15Kg ; 100pcs / 16Kg / CARTON
PACKING
Standard type P1I: 2.1 * 5.5 * 9.5mm turning fork type, center positive for stock ; Other type available by customer requested
PLUG
CONNECTOR
CABLE Standard type UL1185 6ft (4FT only for 5V output) for stock ; Other type available by customer requested
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient.
NOTE
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Tolerance: includes set up tolerance, line regulation, load regulation.
4.Line regulation is measured from low line to high line at rated load.
5.Load regulation is measured from 10% to 100% rated load.
6.The over temperature protection (OTP) is the built-in function of the control IC (U1). The activating level described above is based on the specification
provided by the IC manufacturer.
File Name:GS12U-SPEC 2011-06-1410 ~ 12W AC-DC Single Output Wall-mounted type
G S12U s e ri e s
Mechanical Specification
Unit:mm
UL1185 16AWG 1230 50mm for 5V~9V
UL1185 18AWG 1830 50mm for 12V~24V
30 10mm
6.3 0.3
65 1
ID 2.1 x OD 5.5
9.5 0.5mm
Plug Assignment
Standard plug: P1I
P1I
P/N OUTPUT
1.5 0.2
CENTER +
12.7 0.4
Derating Curve
Static Characteristics(24V)
32 300
28 250
100
24 200
70 20 150
16 100
12 50
25
8
0 10 20 30 40 50
50 70 90 110 120 140 160 180 200 220 240 264
Ta ( ) INPUT VOLTAGE(VAC)60Hz
File Name:GS12U-SPEC 2011-06-14
LOAD (%)
47 1
17 1 26.5 1
OUTPUT VOLTAGE (V)
OUTPUT RIPPLE (mVp-p)