22.5~36W AC-DC Single Output Wall-mounted type
G S36 U s erie s
Features :
EUniversal AC input / Full range
ENo load power consumption<0.3W
EErP step2 compliant
ENRCan compliant
EMeet EISA 2007 (Energy Independence and Security Act)
E2 pole USA plug
EClass power (without earth pin)
EProtections: Short circuit / Overload / Over voltage
EFully enclosed plastic case
EApprovals: UL / CUL / BSMI / CB / FCC
EPass LPS
E2 years warranty
SPECIFICATION
ORDER NO. GS36U05-P1J GS36U09-P1J GS36U12-P1J GS36U24-P1J GS36U48-P1J
SAFETY MODEL NO. GS36U05 GS36U09 GS36U12 GS36U24 GS36U48
DC VOLTAGE Note.2 5V 9V 12V 24V 48V
RATED CURRENT 4.5A 3.5A 3A 1.5A 0.75A
CURRENT RANGE 0 ~ 4.5A 0 ~ 3.5A 0 ~ 3A 0 ~ 1.5A 0 ~ 0.75A
RATED POWER (max.) 22.5W 31.5W 36W 36W 36W
OUTPUT
RIPPLE & NOISE (max.) Note.3 90mVp-p 90mVp-p 100mVp-p 180mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4 5.0% 5.0% 3.0% 2.0% 2.0%
LINE REGULATION Note.5 1.0% 1.0% 1.0% 1.0% 1.0%
LOAD REGULATION Note.6 5.0% 5.0% 3.0% 2.0% 2.0%
SETUP, RISE, HOLD UP TIME 1000ms, 20ms, 50ms/230VAC 1000ms, 20ms, 15ms/115VAC at full load
VOLTAGE RANGE 90 ~ 264VAC 135 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 76.5% 81.5% 84.5% 85.5% 87.5%
INPUT
AC CURRENT 0.7A / 100VAC
INRUSH CURRENT (max.)
35A / 115VAC
LEAKAGE CURRENT(max.)
0.25mA / 240VAC
110 ~ 250% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION
105 ~ 135% rated output voltage
OVER VOLTAGE
Protection type : Clamp by zener diode
-20 ~ +50J (Refer toDerating Curv)
WORKING TEMP.
20% ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY -20 ~ +85J, 10 ~ 95% RH
ENVIRONMENT
TEMP. COEFFICIENT
0.03% /J (0 ~ 5J0 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1, CSA C22.2, BSMI CNS14336 approved
SAFETY &
WITHSTAND VOLTAGE
I/P-O/P:4242VDC
EMC
ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25J/ 70% RH
(Note. 7)
EMC EMISSION Compliance to FCC PART 15 / CISPR22 class B, CNS13438 class B
MTBF 692.3Khrs min. MIL-HDBK-217F(25J)
DIMENSION 79*54*33mm (L*W*H)
OTHERS
226g ; 60pcs / 15.5kg / CARTON
PACKING
PLUG See page2
CONNECTOR
CABLE See page2
1.All parameters are specified at 115VAC input, rated load, 25J 70% RH ambient.
NOTE
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
File Name:GS36U-SPEC 2013-02-2322.5~36W AC-DC Single Output Wall-mounted type
G S36 U s erie s
Mechanical Specification
Unit:mm
UL1185 16AWG 1000 50mm
60 10mm
70 10mm
11 0.5mm
ID 2.1 x OD 5.5
NAME PLATE
Plug Assignment
33
79
P1J
P/N OUTPUT
+
CENTER
Derating Curve Static Characteristics
for 12~48V
100 100
80
70
for 5~9V
60
-20 10 20 30 40 50 0 50 60 70 80 90 100 264
Ta (J) INPUT VOLTAGE
File Name:GS36U-SPEC 2013-02-23
LOAD (%)
54
17
LOAD (%)