40W AC-DC Industrial Adaptor GS40 series 3 2 3 1 , A 9 . , & 9 B 1 21C )94B 9 9 4 9 8 - I , =, & & > 4 B& 2 0 2 0 4 .4B 3 .9 , , = D -6 > SPECIFICATION ORDER NO. GS40A05-P1J GS40A07-P1J GS40A09-P1J GS40A12-P1J GS40A15-P1J GS40A18-P1J GS40A24-P1J GS40A48-P1J SAFETY MODEL NO. GS40A05 GS40A07 GS40A09 GS40A12 GS40A15 GS40A18 GS40A24 GS40A48 DC VOLTAGE Note.2 5V 7.5V 9V 12V 15V 18V 24V 48V RATED CURRENT 5A 5.34A 4.45A 3.34A 2.67A 2.22A 1.67A 0.84A CURRENT RANGE 0 ~ 5A 0 ~ 5.34A 0 ~ 4.45A 0 ~ 3.34A 0 ~ 2.67A 0 ~ 2.22A 0 ~ 1.67A 0 ~ 0.84A RATED POWER (max.) 25W 40W 40W 40W 40W 40W 40W 40W OUTPUT RIPPLE & NOISE (max.) Note.3 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p VOLTAGE TOLERANCE Note.4 5.0% 5.0% 5.0% 3.0% 3.0% 3.0% 2.5% 2.5% LINE REGULATION Note.5 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 5.0% 5.0% 5.0% 3.0% 3.0% 3.0% 2.5% 2.5% SETUP, RISE TIME Note.6 1000ms, 30ms / 230VAC 1000ms, 30ms / 115VAC at full load HOLD UP TIME (Typ.) 50ms / 230VAC 15ms / 115VAC at full load VOLTAGE RANGE Note.7 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 80.5% 85.5% 85% 89% 89.5% 90% 91% 92% INPUT AC CURRENT (Typ.) 1A / 115VAC 0.5A / 230VAC INRUSH CURRENT (max.) 65A / 230VAC LEAKAGE CURRENT(max.) 0.75mA / 240VAC 105 ~ 150% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION 5.25 ~ 6.75V 7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V 25.2 ~ 32.4V 50.4 ~ 64.8V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +60 (Refer toDerating Curv) WORKING TEMP. WORKING HUMIDITY 20% ~ 90% RH non-condensing STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.03% / (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1(except for 48V) approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note. 8) EMC EMISSION Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A MTBF 711K hrs min. MIL-HDBK-217F(25) DIMENSION 125*50*31.5mm (L*W*H) OTHERS 0.28Kg 40pcs/12.02Kg/1.05CUFT PACKING PLUG See page 2 Other type available by customer requested CONNECTOR CABLE See page 2 Other type available by customer requested NOTE %& ( ( ) * + , , & ( - - % . , & & / . & % 012033 & , & , 4 & 5 & 6 %& , & 7 8 & & ,& , & & 9) 3 & , & 9) :9) , < = & 22,,, , > File Name:GS40-SPEC 2015-06-0140W AC-DC Industrial Adaptor GS40 series Mechanical Specification Case No. GS60A Unit:mm UL1185 16AWG 100050mm for 5 ~ 15V UL1185 18AWG 180050mm for 18 ~ 48V 125 31.5 POWER LED 7010mm 110.5mm ID 2.1 x OD 5.5 Outside Inside -V not connected to AC FG Plug Assignment Standard plug: P1J P1J P/N OUTPUT CENTER + Derating Curve Static Characteristics 100 100 90 80 80 60 70 60 40 50 20 40 -30 0 10 20 30 40 50 60 70 (HORIZONTAL) 90 95 100 110 120 140 160 180 200 220 240 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (VAC) 60Hz File Name:GS40-SPEC 2015-06-01 LOAD (%) 50 LOAD (%)