18W AC-DC Reliable Green Medical Adaptor G SM 18E series Users Manual Video I E C / E N 6 0 6 0 1 - 1 I E C / E N 6 0 6 0 1 - 1 - 11 + + BS EN/EN60601-1/-1-11 IEC60601-1/-1-11 TPTC004 File Name:GSM18E-SPEC 2021-12-1518W AC-DC Reliable Green Medical Adaptor G SM 18E series SPECIFICATION ORDER NO. GSM18E05-P1J GSM18E07-P1J GSM18E09-P1J GSM18E12-P1J GSM18E15-P1J GSM18E18-P1J GSM18E24-P1J GSM18E48-P1J SAFETY MODEL NO. GSM18E05 GSM18E07 GSM18E09 GSM18E12 GSM18E15 GSM18E18 GSM18E24 GSM18E48 DC VOLTAGE Note.2 5V 7.5V 9V 12V 15V 18V 24V 48V RATED CURRENT 3A 2A 2A 1.5A 1.2A 1A 0.75A 0.375A CURRENT RANGE 0 ~ 3A 0 ~ 2A 0 ~ 2A 0 ~ 1.5A 0 ~ 1.2A 0 ~ 1A 0 ~ 0.75A 0 ~ 0.375A RATED POWER (max.) 15W 15W 18W 18W 18W 18W 18W 18W OUTPUT RIPPLE & NOISE (max.) Note.3 60mVp-p 80mVp-p 80mVp-p 120mVp-p 120mVp-p 150mVp-p 180mVp-p 240mVp-p VOLTAGE TOLERANCE Note.4 5.0% 5.0% 5.0% 3.0% 3.0% 3.0% 2.0% 2.0% LINE REGULATION Note.5 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 5.0% 5.0% 5.0% 3.0% 3.0% 3.0% 2.0% 2.0% SETUP, RISE TIME Note.6 500ms, 30ms / 230VAC 1000ms, 30ms / 115VAC at full load HOLD UP TIME (Typ.) 16ms / 230VAC 16ms / 115VAC at full load VOLTAGE RANGE Note.7 80 ~ 264VAC 113 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz EFFICIENCY (Typ.) 80% 83% 84% 85% 85.5% 86% 87% 88% INPUT AC CURRENT (Typ.) 0.5A / 115VAC 0.25A / 230VAC INRUSH CURRENT (Typ.) 55A / 230VAC 30A / 115VAC LEAKAGE CURRENT(max.) Touch current < 50 A/264VAC 105 ~ 170% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION 5.25 ~ 7.5V 7.88 ~ 10.13V 9.45 ~ 12.6V 12.6 ~ 17.2V 15.75 ~ 20.25V 18.9 ~ 24.3V 25.2 ~ 32.4V 50.4 ~ 64.8V OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover -25 ~ +60 (Refer toDerating Curv) WORKING TEMP. WORKING HUMIDITY 20% ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03% / (0~40) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS TUV BS EN/EN60601-1 / BS EN/EN60601-1-11, EAC TP TC 004 approved ISOLATION LEVEL Primary-Secondary: 2xMOPP WITHSTAND VOLTAGE I/P-O/P:4KVAC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Parameter Standard Test Level / Note Conducted emission BS EN/EN55011 (CISPR11) Class B EMC EMISSION Radiated emission BS EN/EN55011 (CISPR11) Class B SAFETY & Harmonic current BS EN/EN61000-3-2 Class A EMC (Note. 8) BS EN/EN61000-3-3 ----- Voltage flicker BS EN/EN60601-1-2, BS EN/EN61204-3 Parameter Standard Test Level / Note ESD BS EN/EN61000-4-2 Level 4, 15KV air Level 4, 8KV contact Level 3, 10V/m( 80MHz~2.7GHz ) RF field susceptibility BS EN/EN61000-4-3 Table 9, 9~28V/m( 385MHz~5.78GHz ) EFT bursts BS EN/EN61000-4-4 Level 3, 2KV EMC IMMUNITY Surge susceptibility BS EN/EN61000-4-5 Level 3, 1KV/Line-Line Conducted susceptibility BS EN/EN61000-4-6 Level 3, 10V Magnetic field immunity BS EN/EN61000-4-8 Level 4, 30A/m 100% dip 1 periods, 30% dip 25 periods, Voltage dip, interruption BS EN/EN61000-4-11 100% interruptions 250 periods 796.7K hrs min. MIL-HDBK-217F(25) MTBF DIMENSION 79*54*33mm (L*W*H) OTHERS PACKING 200g 60pcs / 13Kg / CARTON PLUG See page 4~5 Other type available by customer requested CONNECTOR CABLE See page 4~5 Other type available by customer requested NOTE (as available on