90W AC-DC High Reliability Medical Adaptor G SM 90B series File Name:GSM90B-SPEC 2016-03-1690W AC-DC High Reliability Medical Adaptor G SM 90B series SPECIFICATION ORDER NO. GSM90B12-P1M GSM90B15-P1M GSM90B19-P1M GSM90B24-P1M GSM90B48-P1M SAFETY MODEL NO. GSM90B12 GSM90B15 GSM90B19 GSM90B24 GSM90B48 DC VOLTAGE Note.2 12V 15V 19V 24V 48V RATED CURRENT 6.67A 6A 4.74A 3.75A 1.87A CURRENT RANGE 0 ~ 6.67A 0 ~ 6A 0 ~ 4.74A 0 ~ 3.75A 0 ~ 1.87A RATED POWER (max.) 80W 90W 90W 90W 90W OUTPUT RIPPLE & NOISE (max.) Note.3 120mVp-p 150mVp-p 180mVp-p 200mVp-p 240mVp-p VOLTAGE TOLERANCE Note.4 5.0% 5.0% 4.0% 3.0% 2.5% LINE REGULATION Note.5 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 5.0% 5.0% 4.0% 3.0% 2.5% SETUP, RISE TIME Note.6 1000ms, 50ms / 230VAC 1500ms, 50ms / 115VAC at full load HOLD UP TIME (Typ.) 20ms / 230VAC 20ms / 115VAC at full load VOLTAGE RANGE Note.7 80 ~ 264VAC 113 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.91 / 230VAC PF>0.95 / 115VAC at full load INPUT EFFICIENCY (Typ.) 88% 89% 89% 90% 91% AC CURRENT (Typ.) 1.3A / 115VAC 0.6A / 230VAC INRUSH CURRENT (Typ.) 30A / 115VAC 65A / 230VAC LEAKAGE CURRENT(max.) Touch current < 100 A/264VAC 110 ~ 150% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION 105 ~ 135% rated output voltage OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover OVER TEMPERATURE WORKING TEMP. -30 ~ +60 (Refer toDerating Curv) WORKING HUMIDITY 20% ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03% / (0 ~ 40) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes SAFETY STANDARDS ANSI/AAMI ES60601-1 / ES60601-1-11, TUV EN60601-1 / EN60601-1-11 approved ISOLATION LEVEL Primary-Secondary: 2xMOPP SAFETY & WITHSTAND VOLTAGE I/P-O/P: 4KVAC EMC (Note. 8) I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH ISOLATION RESISTANCE EMC EMISSION Compliance to EN55011(CISPR11) class B, EN61000-3-2,3, FCC PART 15 class B,CAN ICES-3(B)/NMB-3(B) EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3 medical level, criteria A MTBF 405.6K hrs min. MIL-HDBK-217F(25) DIMENSION 145*60*32mm (L*W*H) OTHERS PACKING 0.45Kg 30pcs/14.5Kg/1CUFT PLUG See page 3 Other type available by customer requested CONNECTOR CABLE See page 3 Other type available by customer requested NOTE For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on