120W AC-DC Single Output Desktop G ST120A series File Name:GST120A-SPEC 2015-01-13120W AC-DC Single Output Desktop G ST120A series SPECIFICATION GST120A20- GST120A24- GST120A48- ORDER NO. GST120A12-R7B GST120A15-R7B =R7B,P1M =R7B,P1M =R7B,P1M SAFETY MODEL NO. GST120A12 GST120A15 GST120A20 GST120A24 GST120A48 DC VOLTAGE 12V 15V 20V 24V 48V RATED CURRENT 8.5A 7A 6A 5A 2.5A CURRENT RANGE 0 ~ 8.5A 0 ~ 7A 0 ~ 6A 0 ~ 5A 0 ~ 2.5A RATED POWER (max.) 102W 105W 120W 120W 120W RIPPLE & NOISE (max.) Note.2 120mVp-p 150mVp-p 180mVp-p 200mVp-p 240mVp-p OUTPUT VOLTAGE TOLERANCE Note.3 5.0% 5.0% 5.0% 3.0% 2.5% LINE REGULATION Note.4 1.0% 1.0% 1.0% 1.0% 1.0% LOAD REGULATION 5.0% 5.0% 4.0% 3.0% 2.5% SETUP, RISE TIME Note.5 2000ms, 30ms / 230VAC 2500ms, 30ms / 115VAC at full load HOLD UP TIME (Typ.) 20ms / 230VAC 20ms / 115VAC at full load VOLTAGE RANGE Note.6 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.93 / 230VAC PF>0.97 / 115VAC at full load R7B 88.5% 89% 90% 90.5% 91% INPUT EFFICIENCY (Typ.) P1M ----- ----- 89% 89.5% 90.5% AC CURRENT 1.4A / 115VAC 0.7A / 230VAC INRUSH CURRENT (max.) 70A / 230VAC LEAKAGE CURRENT(max.) 0.75mA / 240VAC 105 ~ 160% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION 105 ~ 135% rated output voltage OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, re-power on to recover -30 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20% ~ 90% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.03% / (0~45 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, J60950-1 approved SAFETY STANDARDS WITHSTAND VOLTAGE I/P-O/P: 3KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH EMC (Note. 7) EMC EMISSION Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A MTBF 368.75K hrs min. MIL-HDBK-217F(25) DIMENSION 167*67*35mm (L*W*H) OTHERS PACKING 0.62Kg 20pcs/13.4Kg/0.9CUFT See page 3 Other type available by customer requested PLUG CONNECTOR See page 3 Other type available by customer requested CABLE NOTE File Name:GST120A-SPEC 2015-01-13