240W Constant Voltage + Constant Current LED Driver HBG -2 4 0 se rie s IS 15885(Part 2/Sec13) THOMAS SAMUEL THOMAS SAMUEL I P 6 5 I P 6 7 R-41027766 (for DA Type only) (for 48A,60A only) A File Name:HBG-240-SPEC 2020-09-25240W Constant Voltage + Constant Current LED Driver HBG -2 4 0 se rie s SPECIFICATION HBG-240-24 HBG-240-36 HBG-240-48 HBG-240-60 MODEL 24V 36V 48V 60V DC VOLTAGE 14.4 ~ 24V 21.6 ~ 36V 28.8 ~ 48V 36 ~ 60V CONSTANT CURRENT REGION Note.2 CONSTANT CURRENT REGION 16.8 ~ 24V 25.2 ~ 36V 33.6 ~ 48V 42 ~ 60V (for DA Type only) 10A 6.7A 5A 4.0A RATED CURRENT RATED POWER Note.5 240W 240W 240W 240W 150mVp-p 250mVp-p 250mVp-p 350mVp-p RIPPLE & NOISE (max.) Note.3 Adjustable for A/AB-Type (via built-in potentiometer) OUTPUT CURRENT ADJ. RANGE 4.0 ~ 6.7A 3 ~ 5A 2.4 ~ 4.0A 6 ~ 10A VOLTAGE TOLERANCE Note.4 2.0% 0.5% LINE REGULATION LOAD REGULATION 0.5% SETUP, RISE TIME Note.6 500ms,120ms /230VAC 2500ms,120ms /115VAC HOLD UP TIME (Typ.) 15ms /115VAC, 230VAC 90 ~ 305VAC 127 ~ 431VDC VOLTAGE RANGE Note.5 (Please refer toSTATIC CHARACTERISTI section) FREQUENCY RANGE 47 ~ 63Hz PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC full load POWER FACTOR (Please refer toPOWER FACTOR (PF) CHARACTERISTI section) THD< 20%( load60%/115VC,230VAC load80%/277VAC) TOTAL HARMONIC DISTORTION INPUT (Please refer to TOTAL HARMONIC DISTORTION(THD) section) EFFICIENCY (Typ.) Note.7 92.5% 92.5% 93% 93.5% AC CURRENT (Typ.) 2.5A / 115VAC 1.3A / 230VAC 1.2A / 277VAC INRUSH CURRENT (Typ.) COLD START 75A(twidth=680s measured at 50% Ipeak) at 230VAC Per NEMA 410 MAX. No. of PSUs on 16A 2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC CIRCUIT BREAKER LEAKAGE CURRENT <0.75mA / 277VAC 95 ~ 108% OVER CURRENT Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed PROTECTION 43 ~ 52V 52 ~ 63V 62 ~ 85V 27 ~ 34V OVER VOLTAGE Shut down and latch off o/p voltage, re-power on to recover OVER TEMPERATURE Shut down o/p voltage, recovers automatically after temperature goes down WORKING TEMP. Tcase=-40 ~ +75 (Please refer to OUTPUT LOAD vs TEMPERATURE section) MAX. CASE TEMP. Tcase=+75 WORKING HUMIDITY 20 ~ 95% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750,CSA C22.2 No.250.13-12, ENEC EN61347-1, EN61347-2-13 independent, EN62384 GB19510.1,GB19510.14, SAFETY STANDARDS BIS IS15885(for 48A,60A only), EAC TP TC 004, IP65 or IP67 approved DALI STANDARDS C o m p l i a n c e t o I E C 6 2 3 8 6 - 1 0 1 , 1 0 2 , 2 0 7 f o r D A - T y p e o n l y SAFETY & WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC EMISSION Note.9 Compliance to EN55015, EN61000-3-2 Class C ( load75%) EN61000-3-3, GB17743 and GB17625.1, EAC TP TC 020 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547,light industry level (surge immunity:Line-Earth:4KV,Line-Line:2KV), EAC TP TC 020 EMC IMMUNITY MTBF 663.8K hrs min. Telcordia SR-332 (Bellcore) 190.7Khrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 191.5mm *69mm (D * H) 2.1Kg 8pcs/18.3Kg/2.09CUFT PACKING NOTE Product Liability DisclaimerFor detailed information, please refer to