300W Constant Power Mode LED Driver HBG C-300 series 05 2 I P 6 7 ( H,M Type only) I File Name:HBGC-300-SPEC 2019-06-24300W Constant Power Mode LED Driver HBG C-300 series SPECIFICATION MODEL HBGC-300-L- HBGC-300-M- HBGC-300-H- DEFAULT CURRENT 1400mA 2800mA 5600mA RATED POWER 301.6W 301.6W 301.6W CONSTANT CURRENT REGION 116 ~232V 58 ~ 116V 29 ~ 58V FULL POWER CURRENT RANGE 1300~2170mA 2600~4330mA 5200~8670mA OUTPUT OPEN CIRCUIT VOLTAGE (max.) 240V 120V 62V CURRENT ADJ. RANGE 650~2170mA 1300~4330mA 2600~8670mA CURRENT RIPPLE 5.0% max. rated current CURRENT TOLERANCE 5% SET UP TIME 500ms/230VAC, 500ms/115VAC 90 ~ 305VAC 127VDC ~ 431VDC VOLTAGE RANGE Note.2 (Please refer toSTATIC CHARACTERISTI section) FREQUENCY RANGE 47 ~ 63Hz PF0.97 / 115VAC, PF0.95 / 230VAC, PF0.92 / 277VAC at full load POWER FACTOR (Typ.) (Please refer toPower Factor Characteristi section) THD< 10% ( load50% at 115VAC/230VAC , load75% at 277VAC) TOTAL HARMONIC DISTORTION Please refer to TOTAL HARMONIC DISTORTION (THD) section INPUT EFFICIENCY (Typ.) 94.5% 93.5% 92.5% AC CURRENT (Typ.) 3A / 115VAC 1.6A / 230VAC 1.3A / 277VAC INRUSH CURRENT(Typ.) COLD START 45A(twidth=1300 s measured at 50% Ipeak) at 230V AC Per NEMA 410 MAX. NO. of PSUs on 16A 2 unit(circuit breaker of type B) / 4 units(circuit breaker of type C) at 230VAC CIRCUIT BREAKER LEAKAGE CURRENT <0.75mA / 277VAC NO LOAD / STANDBY Standby power consumption <0.5W for AB / DA-Type POWER CONSUMPTION Blank/A-Type please refer to Note. 5 Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT 241 ~ 275V 121 ~ 145V 61 ~ 78V PROTECTION OVER VOLTAGE Shut down output voltage, re-power on to recovery Tcase>80 5,derate power automatically by 6%/ max. OVER TEMPERATURE Tcase=-40 ~ +80(Please refer toOUTPUT LOAD vs TEMPERATUR section) WORKING TEMP. MAX. CASE TEMP. Tcase=+80 20 ~ 95% RH non-condensing ENVIRONMENT WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH non-condensing TEMP. COEFFICIENT 0.03%/ (0 ~ 60) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750(typeHL), CSA C22.2 No. 250.13-12 ENEC EN61347-1, EN61347-2-13 independent, EN62384 SAFETY STANDARDS EAC TP TC 004 GB19510.1,GB19510.14 IP67 approved WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC EMC EMISSION Compliance to EN55015, EN61000-3-2 Class C ( load50%) EN61000-3-3,EAC TP TC 020 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV),EAC TP TC 020 EMC IMMUNITY MTBF 561.2K hrs min. Telcordia SR-332(Bellcore) 154.9K hrs min. MIL-HDBK-217F (25) LIFETIME Note.4 50000 hrs min. 191.5mm *69mm OTHERS DIMENSION 2.2Kg 8pcs/19.8Kg/2.09CUFT PACKING NOTE File Name:HBGC-300-SPEC 2019-06-24