75W Single Output with PFC Function HRP-75 series Users Manual % & ( ) * + , , * - . ) ( ( * ( Bauart gepruft Sicherheit egelma ge od os be wac g www.tuv.com ID 2000000000 UL62368-1 BS EN/EN62368-1 TPTC004 IEC62368-1 SPECIFICATION MODEL HRP-75-3.3 HRP-75-5 HRP-75-7.5 HRP-75-12 HRP-75-15 HRP-75-24 HRP-75-36 HRP-75-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V RATED CURRENT 15A 15A 10A 6.3A 5A 3.2A 2.1A 1.6A CURRENT RANGE 0 ~ 15A 0 ~ 15A 0 ~ 10A 0 ~ 6.3A 0 ~ 5A 0 ~ 3.2A 0 ~ 2.1A 0 ~ 1.6A RATED POWER 49.5W 75W 75W 75.6W 75W 76.8W 75.6W 76.8W RIPPLE & NOISE (max.) Note.2 80mVp-p 80mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p OUTPUT VOLTAGE ADJ. RANGE 3.1 ~ 3.8V 4.7 ~ 5.8V 7.1 ~ 9V 11 ~ 13.8V 14.2 ~ 18V 21.6 ~ 28.8V 32 ~ 39.6V 45 ~ 55.2V VOLTAGE TOLERANCE Note.3 2.5% 2.5% 2.5% 1.5% 1.5% 1.5% 1.5% 1.5% LINE REGULATION 1.0% 1.0% 1.0% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 2.0% 2.0% 1.5% 1.0% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1800ms, 25ms/230VAC 1800ms, 25ms/115VAC at full load HOLD UP TIME (Typ.) 50ms/230VAC 20ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC 120 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.9/230VAC PF>0.95/115VAC at full load INPUT EFFICIENCY (Typ.) 77% 82.5% 84% 87% 88% 88.5% 89% 89% AC CURRENT (Typ.) 0.9A/115VAC 0.5A/230VAC INRUSH CURRENT (Typ.) 35A/115VAC 65A/230VAC LEAKAGE CURRENT <1mA / 240VAC 105 ~ 135% rated output power OVERLOAD Protection type : Constant current limiting, switch to hiccup mode for Vo<50% of rated voltage, recovers automatically after fault condition is removed 3.96 ~ 4.62V 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V PROTECTION OVER VOLTAGE Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE (OPTIONAL) Shut down o/p voltage, recovers automatically after temperature goes down RC+ / RC-: 0 ~ 0.8V = power on 4 ~ 10V = power off FUNCTION REMOTE CONTROL -40 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85, 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH EMC (Note 4) EMC EMISSION Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55024,BS EN/EN61000-6-2,heavy industry level, criteria A,EAC TP TC 020 MTBF 394.8K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 129*98*38mm (L*W*H) PACKING 0.47Kg 30pcs/ 15Kg/ 0.97CUFT ). , / ( 0 1 0 . NOTE 0. 2 3 0 456 * ( )07 * * * .) 3 89 / 1 . 8. / * ( * * : . 4 < ( = * ) > . / : 4 . * 4 1 4A * .B (as available on 3.5 3-M3 L=5 75W Single Output with PFC Function HRP-75 series Mechanical Specification Case No.903D Unit:mm 122.5 1 2 3 4 5 SVR1 CN100 4.5 73.5 Terminal Pin No. Assignment 129 Pin No. Assignment Pin No. Assignment 6.5 120 1 AC/L 4 DC OUTPUT -V 2 AC/N 5 DC OUTPUT +V 3 FG 12 max. Remote ON/OFF (CN100) : JST B-XH or equivalent Pin No. Assignment Mating Housing Terminal 1 RC- JST XHP JST SXH-001T or equivalent or equivalent 2 RC+ 32 77 Block Diagram ACTIVE RECTIFIERS RECTIFIERS EMI +V INRUSH POWER & I/P & FILTER CURRENT SWITCHING -V PFC FILTER LIMITING O.L.P. DETECTION O.T.P. CIRCUIT FG PFC PWM O.V.P. CONTROL CONTROL RC+ REMOTE CONTROL RC- Derating Curve Output Derating VS Input Voltage 100 100 90 80 80 230VAC Input only 70 60 60 40 30 50 20 40 -40 -20 -10 0 20 40 50 60 70 (HORIZONTAL) 85 100 125 135 155 264 AMBIENT TEMPERATURE () INPUT VOLTAGE (V) 60Hz -40 start up possible for 230VAC input File Name:HRP-75-SPEC 2021-09-15 3.5 2-M3 L=5 LOAD (%) 8.2 9.5 1 2 9 LOAD(%) 18.5 31 33 18 9.5 3.5 3.5 28.5 85.5 7 38 98