240W Constant Current Mode LED Driver HVGC-240 series Users Manual IP65 IP67 & 1 ( ) = 3 - > 3 534* 534( , 8 9 0 : < % A ) B + & < B , D( ( % & ~( ) * +( % , - .+%(/0 0 ) 1 2. % , 534* 534( ) % 6 0 0 7 ) % F * & ( & &*( & +( < F C , 53 E A 534( I A ) ) % 5 C - > 534* + & 1& 0 & 3 = < 5 C - I A ) ) G > 534( 5 C - + & 1& 0 & 3 = < Dx 534* > ) 6 % > 6 534* > ) % > 6 File Name:HVGC-240-SPEC 2021-09-03240W Constant Current Mode LED Driver HVG C-240 series SPECIFICATION MODEL HVGC-240-700 HVGC-240-1050 HVGC-240-1400 HVGC-240-1750 HVGC-240-2100 HVGC-240-2800 HVGC-240-3500 1050mA 1400mA 1750mA RATED CURRENT 700mA 2100mA 2800mA 3500mA RATED POWER 240W 240W 240W 240W 240W 240W 240.1W CONSTANT CURRENT REGION Note.2 171.4 ~ 342.8V 114.3 ~ 228.6V 85.7 ~ 171.4V 68.5~137.1V 57.2 ~ 114.3V 42.9 ~ 85.7V 34.3 ~ 68.6V OPEN CIRCUIT VOLTAGE (max.) 354V 235V 176V 141V 117V 88V 71V OUTPUT Adjustable for A/AB-Type only (via built-in potentiometer) CURRENT ADJ. RANGE 350~700mA 525~1050mA 700~1400mA 875~1750mA 1050~2100mA 1400~2800mA 1750~3500mA CURRENT RIPPLE 5.0% max. rated current CURRENT TOLERANCE 5% SET UP TIME Note.4 500ms/230VAC, 347VAC, 480VAC 180 ~ 528VAC 254VDC ~ 747VDC VOLTAGE RANGE Note.3 (Please refer toSTATIC CHARACTERISTI section) FREQUENCY RANGE 47 ~ 63Hz PF0.98/230VAC, PF0.97/277VAC, PF0.95/347VAC, PF0.93/480VAC full load POWER FACTOR (Typ.) (Please refer toPOWER FACTOR (PF) CHARACTERISTI section) THD< 20%( load50%/230VAC, 277VAC, 347VAC, load60%/480VAC) TOTAL HARMONIC DISTORTION (Please refer to TOTAL HARMONIC DISTORTION (THD) section) INPUT EFFICIENCY (Typ.) 93.5% 93% 93% 93% 92.5% 92.5% 92.5% AC CURRENT (Typ.) 0.76A / 347VAC 0.56A / 480VAC INRUSH CURRENT(Typ.) COLD START 50A(twidth= 532 s measured at 50% I peak) at 480VAC Per NEMA 410 MAX. NO. of PSUs on 16A 4unit(circuit breaker of type B) / 6units(circuit breaker of type C) at 480VAC CIRCUIT BREAKER LEAKAGE CURRENT <0.75mA / 480VAC Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT 360 ~ 394V 240 ~ 263V 180 ~ 197V 144 ~ 158V 120 ~ 131.4V 90 ~ 99V 72 ~ 79V PROTECTION OVER VOLTAGE Shut down o/p voltage with re-power on to recovery Shut down and latch off o/p voltage, re-power on to recover OVER TEMPERATURE WORKING TEMP. Tcase=-40 ~ +90(Please refer toOUTPUT LOAD vs TEMPERATUR section) MAX. CASE TEMP. Tcase=+90 20 ~ 95% RH non-condensing WORKING HUMIDITY ENVIRONMENT -40 ~ +80, 10 ~ 95% RH STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03%/ (0 ~ 60) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750 (typeHL), CSA C22.2 No. 250.13-12, IEC/BS EN/EN61347-1,IEC/BS EN/EN61347-2-13, BS EN/EN62384 independent, SAFETY STANDARDS EAC TP TC 004, IP65 or IP67 approved SAFETY & WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC EMC ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to FCC Part 15 Subpart B, BS EN/EN55015, BS EN/EN61000-3-2( load80%), BS EN/EN61000-3-3, EMC EMISSION EAC TP TC 020 Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level (surge immunity Line-Earth 4KV, EMC IMMUNITY Line-Line 2KV), EAC TP TC 020 MTBF 143.6K hrs min. MIL-HDBK-217F (25) 254.2*68*38.8mm (L*W*H) OTHERS DIMENSION 1.35Kg 12pcs/17.2Kg/0.78CUFT PACKING NOTE