Modified Sine Wave DC-AC Inverter with MPPT Solar Charger ISI -50 0 s eries Features : EHigh surge power up to 1000W EPower ON-OFF switch EProtections: Bat. low alarm / Bat. low shutdown / Over temp. / Output short / Input polarity reverse / Over load EHigh frequecny design EAC Output voltage regulation : 10% EAC Output wavform : Modified sine wave EModified models available(optional): 100/115/120VAC or 200/220/240VAC ECooling fan ON-OFF control EBuilt-in 500W MPPT solar charger, MPPT efficiency: 98%(Typ.) EBuilt-in battery low relay contact ELED indicator for operation status E2 years warranty SPECIFICATION MODEL ISI-500-112 ISI-500-124 ISI-500-148 ISI-500-212 ISI-500-224 ISI-500-248 RATED POWER 350W 500W 500W 350W 500W 500W MAXIMUM OUTPUT POWER (Typ.) 550W for 1 minute / surge power 1000W for 30 cycles (112, 212 models : 385W for 1 minute / surge power 700W for 30 cycles) WAVEFORM Modified sine wave OUTPUT AC VOLTAGE 110V 230V FREQUENCY 60Hz 0.5Hz 50Hz 0.5Hz AC REGULATION 10% LED INDICATOR Green: Inverter OK Green (flashing): Inverter OK and charging Red: abnormal 24V 48V 24V 48V BAT. VOLTAGE 12V 12V VOLTAGE RANGE Note.3,4 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC 10.5 ~ 15VDC 21 ~ 30VDC 42 ~ 60VDC DC CURRENT (Typ.) 35A 25A 12.5A 35A 25A 12.5A INPUT 0.8A 0.4A 0.2A NO LOAD CURRENT DRAW 0.8A 0.4A 0.2A OFF MODE CURRENT DRAW 1mA EFFICIENCY (Typ.) Note.1 85% 87% 87% 86% 88% 88% BATTERY TYPE Open & sealed Lead Acid VOLTAGE RANGE 20 ~ 40V 35 ~ 80V 70 ~ 160V 20 ~ 40V 35 ~ 80V 70 ~ 160V SOLAR MAX. SHORT CIRCUIT CURRENT 15A 15A 7.5A 15A 15A 7.5A PANEL INPUT RATED CHARGE POWER (Typ.) 350W 500W 500W 350W 500W 500W MAX. CHARGE VOLTAGE 14V 28V 56V 14V 28V 56V SSOOLLAARR CCHHAARRGGEERR MAX. CHARGE CURRENT 25A 20A 10A 25A 20A 10A FUSE 40A 30A 15A 40A 30A 15A BATTERY BAT. LOW ALARM Note.4 11V 22V 44V 11V 22V 44V INPUT 10.5V 21V 42V 10.5V 21V 42V BAT. LOW SHUTDOWN Note.4 PROTECTION By internal fuse REVERSE POLARITY 65J 1J0 70J 1J0 OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover by internal RTH9 detect on power transistor OUTPUT PROTECTION OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover OVER LOAD Protection type : Shut down o/p voltage, re-power on to recover >105% load 60 sec. Open : Battery low Short : Battery ok FUNCTION BAT. LOW RELAY CONTACT WORKING TEMP. Note.2 -20 ~ +40J 100% load 60J 50% load WORKING HUMIDITY 20% ~ 90% RH non-condensing ENVIRONMENT o STORAGE TEMP., HUMIDITY -30 ~ +70J / -22 ~ +158 F, 10 ~ 95% RH VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes None EN60950-1 LVD WITHSTAND VOLTAGE Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC EMC ISOLATION RESISTANCE Bat. I/P-AC O/P, Bat. I/P-FG, AC O/P-FG:100M Ohms / 500VDC / 25J/ 70% RH EMC EMISSION Compliance to FCC part 15 class A Compliance to EN55022 class A EMS IMMUNITY None Compliance to EN61000-4-2,3,8 o MTBF 81.1K hrs min. MIL-HDBK-217F (25 C) OTHERS DIMENSION 205*158*67mm (L*W*H) PACKING 1.92Kg 6pcs/12.5Kg/1.55CUFT 1.Efficiency is tested by 350W, linear load at 13V, 26V, 52V input voltage. NOTE 2.Output derating capacity referenced by curve 1. 3.Input derating capacity referenced by curve 2. 4.The tolerance of each voltage value by models is:112/212 0.5V 124/224 1V 148/248 2V. 5.All parameters not specified above are measured at rated load, 25J of ambient temperature. File Name:ISI-500-SPEC 2013-01-14Modified Sine Wave DC-AC Inverter with MPPT Solar Charger ISI -50 0 s eries ISI 500 112 A A :TYPE A OUTLET 12:12VDC B :TYPE B OUTLET Modified sine wave inverter Bat. Voltage: 24:24VDC C :TYPE C OUTLET +MPPT solar charger 48:48VDC D :TYPE D OUTLET E :TYPE E OUTLET 1:110VAC U :TYPE U OUTLET Output: O/P Wattage:500W 2:230VAC AC Output Receptacles (optional) Receptacle type TYPE-A TYPE-B TYPE-C TYPE-D TYPE-E TYPE-U (Standard) (Standard) (Optional) (Optional) (Optional) (Optional) Country USA EUROPE AUSTRALIA U.K JAPAN UNIVERSAL Certificate Non Mechanical Specification Unit:mm Input Terminal Pin No. Assignment 5 4 3 2 1 Pin No. Assignment Pin No. Assignment 1 FG 4 Battery POS(+) 2 Solar POS(+) 5 Battery NEG(-) 3 Solar NEG(-) Derating Curve 100 11 7.62 8.9 6.35 Air flow 80 direction 60 50 40 9 20 -20 0 10 20 30 40 50 60 70 (HORIZONTAL) ENVIRONMENT TEMPERATURE (J) CURVE 1 100 80 60 40 20 10.5VDC 11.5VDC 15VDC (HORIZONTAL) 147 158 BATTERY INPUT VOLTAGE (V) CURVE 2 AC OUTPUT AC OUTPUT ON ON OFF OFF Bat. Low Relay Connector : JST B-XH or equivalent Open Battery low Bat. Low Status Bat. Low Status alarm Short Battery OK alarm Type-B Type-A File Name:ISI-500-SPEC 2013-01-14 7 18 13 120 42.5 67 205 LOAD (%) LOAD (%) Reverse Polarity Will Damage The Unit. BATTERY INPUT SOLAR INPUT