NRND 1~4 Output Medical Type 2 00 W M e dica l series Features Universal AC input / Full range Low leakage current <180 A Protections: Short circuit / Overload / Over voltage / Over temperature Free air convection for 140W and forced air convection for 200W ANSI/AAMI ES60601-1 medical safety approved With power good and fail signal output Built-in remote ON-OFF control Built-in remote sense function Fixed switching frequency at 100KHz 3 years warranty Specification AC INPUT VOLTAGE WORKING TEMP. 90~264 VAC, 47~440Hz / 127~370VDC. Whole series can operate from -20~70 . Please refer to the derating curves. POWER FACTOR (Typ.) PF>0.95/230VAC PF>0.98/115VAC at full load WORKING HUMIDITY 20~90% RH non-condensing. AC INPUT CURRENT (Typ.) Maximum input current 3.5A at 115VAC, 60Hz or STORAGE TEMP., HUMIDITY 1.6A at 230VAC, 60Hz with 100% output load. -40~+85 , 10~90% RH INRUSH CURRENT (Typ.) TEMP. COEFFICIENT Inrush current is less than 25A at 115VAC or 0.04%/ on all outputs at full load between 0~50 of ambient temperature. less than 40A at 230VAC under cold start conditions. Limiting provided by internal VIBRATION thermistors. 2G of acceleration, vibrating frequency adjust from 10Hz ~500Hz within a 10-minute cycle. 6 testing cycles (60 minutes) each along X, Y, Z axes. SETUP, RISE TIME 1000ms, 20ms / 230VAC at full load SAFETY STANDARDS 3000ms, 20ms / 115VAC at full load Medical : ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved Commercial : Also design refer to UL60950-1, TUV EN60950-1 HOLD-UP TIME (Typ.) 16ms / 230VAC at full load WITHSTAND VOLTAGE 16ms / 115VAC at full load 4000VAC between input and output 1500VAC between input and F.G. LEAKAGE CURRENT 1500VAC between output and F.G. Leakage current is less than 180 A at 264VAC for earth leakage current ISOLATION RESISTANCE Leakage current is less than 100 A at 264VAC for >100M Ohms for I/P-O/P, I/P-FG, O/P-FG by using 500VDC test voltage. patient leakage current EMI COMPLIANCE DC OUTPUT ADJ. RANGE EMI Specifications Compliance Level DC output voltage (or CH1 of multiple output models) Conducted & Radiation EN55011, Class B can be adjusted between -5%~+10% rated output EN55022, Class B voltage by potential meter. Harmonic distortion EN61000-3-2 Voltage flicker EN61000-3-3 OVERLOAD PROTECTION Fully protected against short circuit and output overload. EMS COMPLIANCE The hiccup type protection will be activated at 120~160% EMS Specification Compliance Level rated load and recovers automatically after fault condition ESD air EN61000-4-2, Level 3, 8KV is removed. ESD contact EN61000-4-2, Level 2, 4KV RF field susceptibility EN61000-4-3, Level 2, 3V/m OVER VOLTAGE PROTECTION Level 3, 10V/m Provided on output channel 1 only at 115%~135% EFT(Electrical Fast Transient)/Burst EN61000-4-4, Level 2, 1KV/5KHz rated output voltage. Level 3, 2KV/5KHz Output will be shut down when this protection is activated. Lightning/Surge EN61000-4-5, Level 4, 2KV/Line-Line 4KV/Line-Earth OVER TEMPERATURE PROTECTION Conducted RF susceptibility EN61000-4-6, Level 2, 3Vrms/m When the temperature of TSW1 which detect on heat sink of Level 3, 10Vrms/m power transistor reaches 95 This protection is activated. Magnetic field immunity EN61000-4-8, Level 2, 3A/m Then output will be shut down and recovers automatically Level 3, 10A/m after temperature goes down. Voltage dip, interruption EN61000-4-11,Compliance Digital phone carrier immunity ENV50204, Level 2, 3V/m, 900MHz POWER GOOD / FAIL SIGNAL Level 3, 10A/m, 900MHz TTL logic high for power good and TTL low for MTBF power fail. When the output voltage reaches 90% of 262,100 hours min. at full load and 25 of ambient temperature, rated value, a +5V TTL signal will be sent out with a calculated per MIL-HDBK-217F. 10~500ms delay At least 1ms before the output voltage goes below 90% of the rated value, the TTL DIMENSION (L*W*H) signal will be turned off. 177.8x107.2x35.5mm or 7 x4.22 x1.4 * MPS-200-3.3 does not have this function. PACKING REMOTE CONTROL 0.66Kg 24pcs/16.8Kg/0.99CUFT RC+/RC-:0 ~ 0.8V=power on 4 ~ 10V=power off sink current<4~10mA File Name:200W MEDICAL-SPEC 2012-02-20NRND 1~4 Output Medical Type 200W Medica l series Output Chart OUTPUT CURRENT RIPPLE & NOISE VOLTAGE OUTPUT RATED LINE LOAD EFFICIENCY PEAK LOAD (Max.) MODEL TOLERANCE MINIMUM WITH FAN VOLTAGE CURRENT CONVECTION REGULATION REGULATION (typ.) WITH 25CFM FAN (Note 2) (Note 3) LOAD (25CFM) (max.) (Note 4) MPS-200-3.3 3.3V 40A 0A 28A 40A 48A 80mVp-p 2.0% 0.5% 1.0% 77% MPS-200-5 5V 40A 0A 28A 40A 48A 80mVp-p 2.0% 0.5% 1.0% 81% MPS-200-12 12V 16.7A 0A 11.7A 16.7A 20A 100mVp-p 2.0% 0.5% 1.0% 84% MPS-200-15 15V 13.4A 0A 9.4A 13.4A 16A 100mVp-p 2.0% 0.5% 1.0% 85% MPS-200-24 24V 8.4A 0A 5.9A 8.4A 10A 150mVp-p 1.0% 0.5% 1.0% 86% MPS-200-48 48V 4.2A 0A 3A 4.2A 5A 200mVp-p 1.0% 0.5% 1.0% 87% MPD-200A 5V 20A 4A 15A 20A 24A 80mVp-p 2.0% 0.5% 1.0% 82% 12V 8A 0.8A 5.4A 8A 9.6A 120mVp-p +8,-5% 1.0% 4.0% MPD-200B 5V 20A 4A 15A 20A 24A 80mVp-p 2.0% 0.5% 1.0% 83% 24V 4A 0.4A 2.7A 4A 4.8A 180mVp-p 6.5% 1.0% +4,-6% MPT-200A 5V 20A 4A 15A 20A 24A 80mVp-p 2.0% 0.5% 1.0% 12V 7.5A 0.8A 5A 7.5A 9A 120mVp-p 8.0% 1.0% 5.0% 80% -5V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPT-200B 5V 20A 4A 15A 20A 24A 80mVp-p 2.0% 0.5% 1.0% 12V 6A 0.6A 4.4A 6A 7.2A 120mVp-p 8.0% 1.0% 5.0% 80% -12V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPT-200C 5V 20A 4A 15A 20A 24A 80mVp-p 2.0% 0.5% 1.0% 15V 4.7A 0.5A 3.3A 4.7A 5.6A 150mVp-p 8.0% 1.0% 5.0% 80% -15V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPT-200D 5V 20A 4A 15A 20A 24A 80mVp-p 2.0% 0.5% 1.0% 24V 3A 0.3A 2.2A 3A 3.6A 180mVp-p 8.0% 1.0% 5.0% 81% 12V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPQ-200B 5V 15A 3A 12A 15A 18A 80mVp-p 2.0% 0.5% 1.0% 12V 7A 0.7A 5.3A 7A 8.4A 120mVp-p 8.0% 1.0% 5.0% 78% -5V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% -12V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPQ-200C 5V 15A 3A 12A 15A 18A 80mVp-p 2.0% 0.5% 1.0% 15V 5A 0.5A 4A 5A 6A 150mVp-p 6.0% 1.0% 5.0% 78% -5V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% -15V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPQ-200D 5V 15A 3A 12A 15A 18A 80mVp-p 2.0% 0.5% 1.0% 24V 3A 0.3A 2.3A 3A 3.6A 180mVp-p 8.0% 1.0% 5.0% 79% 12V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% -12V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% MPQ-200F 5V 15A 3A 12A 15A 18A 80mVp-p 2.0% 0.5% 1.0% 24V 2.7A 0.3A 2.1A 2.7A 3.3A 180mVp-p 8.0% 1.0% 5.0% 81% 15V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% -15V 2A 0A 1A 2A 2.4A 80mVp-p 5.0% 0.5% 1.0% Notes : 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1 f & 47 f parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on