120W Single Output LED Driver NPF-120D series 05 I P 6 7 BE File Name:NPF-120D-SPEC 2019-01-10120W Single Output LED Driver NPF-120D series SSPPEECCIIFFIICCAATTIIOON N MODEL NPF-120D-12 NPF-120D-15 NPF-120D-20 NPF-120D-24 NPF-120D-30 NPF-120D-36 NPF-120D-42 NPF-120D-48 NPF-120D-54 RATED CURRENT 10A 8A 6A 5A 4A 3.4A 2.9A 2.5A 2.3A RATED POWER 120W 120W 120W 120W 120W 122.4W 121.8W 120W 124.2W CONSTANT CURRENT REGION 7.2 ~ 12V 9 ~ 15V 12 ~ 20V 14.4 ~ 24V 18 ~ 30V 21.6 ~ 36V 25.2 ~ 42V 28.8 ~ 48V 32.4 ~ 54V 5.0% max. rated current OUTPUT CURRENT RIPPLE CURRENT TOLERANCE 5.0% AUXILIARY DC OUTPUT Nominal 12V(deviation 11.4~12.6V) 0.2A for BE-Type only Note.4 SET UP TIME Note.3 500ms/115VAC, 230VAC 90 ~ 305VAC 127 ~ 431VDC VOLTAGE RANGE Note.2 (Please refer toSTATIC CHARACTERISTI section) FREQUENCY RANGE 47 ~ 63Hz PF0.97/115VAC, PF0.96/230VAC, PF0.94/277VAC full load POWER FACTOR (Typ.) (Please refer toPOWER FACTOR (PF) CHARACTERISTI section) THD< 20%( load60%/115VC, 230VAC load75%/277VAC) TOTAL HARMONIC DISTORTION (Please refer to TOTAL HARMONIC DISTORTION(THD) section) INPUT 87.5% 88% 89% 89.5% 89% 89.5% 89.5% 90% 90% BLANK-TYPE EFFICIENCY (Typ.) BE-TYPE(Note.5) 87.5% 87.5% 88.5% 89% 88.5% 89% 89% 89% 89% AC CURRENT (Typ.) 1.3A / 115VAC 0.65A / 230VAC 0.55A / 277VAC INRUSH CURRENT(Typ.) COLD START60A(twidth=520 s measured at 50% Ipeak) at 230V AC Per NEMA 410 MAX. NO. of PSUs on 16A 4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC CIRCUIT BREAKER LEAKAGE CURRENT <0.25mA / 277VAC <0.5W STANDBY POWER CONSUMPTION 95 ~ 108% OVER CURRENT Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed PROTECTION 15 ~ 17V 17.5 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 40V 41 ~ 46V 46 ~ 54V 54 ~ 60V 59 ~ 66V OVER VOLTAGE Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover OVER TEMPERATURE WORKING TEMP. Tcase=-40 ~ +90 (Please refer to OUTPUT LOAD vs TEMPERATURE section) MAX. CASE TEMP. Tcase=+90 20 ~ 95% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +80, 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 40 ) VIBRATION 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750(typeHL), CSA C22.2 No. 250.13-12, ENEC EN61347-1, EN61347-2-13, EN62384 independent,EAC TP TC 004, SAFETY STANDARDS GB19510.1,GB19510.14,IP67 approved Design refer to EN60335-1 SAFETY & WITHSTAND VOLTAGE I/P-O/P:3.75KVAC EMC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH EMC EMISSION Compliance to EN55015, EN61000-3-2 Class C ( load60%) EN61000-3-3 GB17743 and GB17625.1, EAC TP TC 020 EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11 EN61547, light industry level(surge immunity Line-Line 2KV) EAC TP TC 020 MTBF 877.8K hrs min. Telcordia SR-332 (Bellcore) 233.9K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 191*63*37.5mm (L*W*H) 0.97Kg 15pcs/15.6Kg/0.87CUFT PACKING NOTE File Name:NPF-120D-SPEC 2019-01-10