1700W High Reliable True Sine Wave DC-AC Power Inverter NT S-17 0 0 se ri e s Users Manual Video E13 UL458 IEC62368-1 BS EN/EN62368-1 (for 112/124 type GFCI only) TPTC004 AS/NZS 62368.1 Please refer to page3 for more details. - File Name:NTS-1700-SPEC 2022-03-041700W High Reliable True Sine Wave DC-AC Power Inverter NT S-1 7 0 0 seri es SPECIFICATION NTS-1700-112 NTS-1700-124 NTS-1700-148 NTS-1700-212 NTS-1700-224 NTS-1700-248 MODEL NO. = US, GFCI, UN = EU, CN, AU, UK, UN RATED POWER(Continuous) 1500W 1700W OVER RATED POWER(3 Min.) 1750W 2000W PEAK POWER(10 Sec.) 2200W 2550W SURGE POWER(30 Cycles) 3000W 3400W Default setting set at 110VAC Default setting set at 230VAC AC VOLTAGE AC OUTPUT 100 / 110 / 115 / 120Vac selectable by DIP S.W 200 / 220 / 230 / 240Vac selectable by DIP S.W Default setting set at 600.1Hz Default setting set at 500.1Hz FREQUENCY 50/60Hz selectable by DIP S.W 50/60Hz selectable by DIP S.W WAVEFORM Note.1 True sine wave (THD<3%) AC REGULATION 3.0% at rated input voltage FRONT PANEL LED Please see page 5 24Vdc 48Vdc 24Vdc 48Vdc DC VOLTAGE 12Vdc 12Vdc VOLTAGE RANGE (Typ.) 10 ~ 16.5Vdc 20 ~ 33Vdc 40 ~ 66Vdc 10 ~ 16.5Vdc 20 ~ 33Vdc 40 ~ 66Vdc DC CURRENT (Typ.) 150A 75A 37.5A 170A 85A 42.5A DC INPUT Default disable, 1.2W ~1.5W by models auto detect AC output load10W will be changed to saving mode NO LOAD DISSPATION (SAVING MODE)(Typ.) Note.2 1.2W 1.4W 1.5W 1.2W 1.4W 1.5W OFF MODE CURRENT DRAW 1mA EFFICIENCY (Typ.) Note.1 89% 90% 91% 89% 92% 93% BATTERY TYPES Lead Acid or li-ion FUSE (INTERNAL) 40A*6 40A*3 25A*3 40A*6 40A*3 25A*3 110.3Vdc 220.5Vdc 441Vdc 110.3Vdc 220.5Vdc 441Vdc ALARM LOW SHUTDOWN 100.3Vdc 200.5Vdc 401Vdc 100.3Vdc 200.5Vdc 401Vdc 12.50.3Vdc 250.5Vdc 501Vdc 12.50.3Vdc 250.5Vdc 501Vdc RESTART 15.50.3Vdc 310.5Vdc 621Vdc 15.50.3Vdc 310.5Vdc 621Vdc ALARM HIGH SHUTDOWN 16.50.3Vdc 330.5Vdc 661Vdc 16.50.3Vdc 330.5Vdc 661Vdc 150.3Vdc 300.5Vdc 601Vdc 150.3Vdc 300.5Vdc 601Vdc RESTART By internal fuse open BAT. POLARITY OVER TEMPERATURE Protection type : Shut down o/p voltage, re-power on to recover OUTPUT SHORT Protection type : Shut down o/p voltage, re-power on to recover 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. OVER LOAD (Typ.) Protection type : Shut down o/p voltage, re-power on to recover CIRCUIT BREAKER 15A 10A (ONLY FOR GFCIAC SOCKET) GFCI PROCTECTION UL458 (Only for GFCI AC socket, by request) None CONNECTOR Power ON-OFF remote control by front panel dry contact connector(by RELAY), Open : Normal work Short : Remote off REMOTE FUNCTION CONTROL ACCESSORY Remote controller sold separately, Order No.: IRC1,IRC2,IRC3 RS-232 COMMUNICATION RS-232 ~ RJ11 Type connector (Please refer to page 4 for more details) WORKING TEMP. -25 ~ +70(Refer to Derating curve) WORKING HUMIDITY 20% ~ 90% RH non-condensing ENVIRONMENT o STORAGE TEMP., HUMIDITY -30 ~ +70 / -22 ~ +158 F, 10 ~ 95% RH non-condensing VIBRATION 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes CB IEC62368-1,Dekra BS EN/EN62368-1,UL458, E13,EAC TP TC 004,AS/NZS 62368.1 approved SAFETY STANDARDS (Please refer to next pageAC output socket table for more details) WITHSTAND VOLTAGE DC I/P - AC O/P:3.0KVac AC O/P - FG:1.5KVac Parameter Standard Test Level / Note FCC for 112,124,148 only(expect for Type-UN) Class A Radiated EMC EMISSION BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN) Class A Harmonic Current BS EN/EN61000-3-2 ----- Voltage Flicker BS EN/EN61000-3-3 ----- SAFETY & BS EN/EN55024, BS EN/EN55035 EMC Parameter Standard Test Level / Note (Note.5) ESD BS EN/EN61000-4-2 Level 3, 8KV air Level 2, 4KV contact EMC IMMUNITY Radiated BS EN/EN61000-4-3 Level 2, 3V/m Magnetic Field BS EN/EN61000-4-8 Level 1, 1A/m MTBF 475.5K hrs min. Telcordia TR/SR-332 (Bellcore) 46.2K hrs min. MIL-HDBK-217F (25) OTHERS DIMENSION 400*184*70mm (L*W*H) 4.63Kg 2pcs/ 12Kg/ 1.76CUFT PACKING NOTE