16W Single Output LED Power Supply PLD-16 series 3 5 Users Manual .9: ) 9: ( < ( ,3 , 5 = / >( ( 3 , 6 3 4, = %& - 0 %& : ( ( 2 % ) IP42 0 < 2 0 : 2 0 < 2 0 < 2 0 < 2 0 < 2 ,% 1 ). : : 5 A : B C ).9: < 5 A : D C B.9: SPECIFICATION MODEL PLD-16-350 PLD-16-700 PLD-16-1050 PLD-16-1400 RATED CURRENT 350mA 700mA 1050mA 1400mA OPERATING VOLTAGE RANGE 24 ~ 48V 16 ~ 24V 12 ~ 16V 8 ~ 12V CURRENT ACCURACY 5.0% OUTPUT RATED POWER 16.8W 16.8W 16.8W 16.8W RIPPLE & NOISE (max.) Note.1 4.6Vp-p 2.7Vp-p 2.2Vp-p 2Vp-p NO LOAD OUTPUT VOLTAGE (max.) 60V 35V 25V 16V SETUP TIME 500ms / 230VAC 2000ms / 115VAC at full load FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.9/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer toPower Factor Characteristi curve) A series THD< 20% when output loading70% at 115VAC TOTAL HARMONIC DISTORTION B series THD< 20% when output loading70% at 230VAC input and output loading 80% at 277VAC input A series 84.5% 84.5% 84% 82.5% EFFICIENCY (Typ.) INPUT 85.5% 86% 85% 83.5% B series AC CURRENT (Typ.) 0.4A/115VAC 0.2A/230VAC 0.15A/277VAC INRUSH CURRENT(Typ.) COLD START 20A(twidth=25s measured at 50% Ipeak) at 230VAC MAX. No. of PSUs A series 58 units (circuit breaker of type B) / 58 units (circuit breaker of type C) at 115VAC on 16A CIRCUIT B series 128 units (circuit breaker of type B) / 128 units (circuit breaker of type C) at 230VAC BREAKER LEAKAGE CURRENT <0.5mA / 240VAC SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed. PROTECTION OVER TEMPERATURE Shut down o/p voltage, re-power on to recover -30 ~ +50 (Refer toDerating Curv) WORKING TEMP. 20 ~ 95% RH non-condensing WORKING HUMIDITY -40 ~ +80, 10 ~ 95% RH ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT 0.03%/ (0 ~ 50) VIBRATION 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750,CSA C22.2 No.250.0-08 ENEC BS EN/EN 613471-1,BS EN/EN 61347-2-13 independent, SAFETY STANDARDS BS EN/EN62384(for B type only), EAC TP TC 004, IP42 approved WITHSTAND VOLTAGE I/P-O/P:3.75KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH EMC Compliance to BS EN/EN55015 (B type only), BS EN/EN61000-3-2 Class C BS EN/EN61000-3-3, EMC EMISSION FCC part 18 non-consumer equipment(A type only), EAC TP TC 020 EMC IMMUNITY Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level, criteria A, EAC TP TC 020 MTBF 906.5Khrs min. MIL-HDBK-217F (25) 84*57*29.5mm (L*W*H) OTHERS DIMENSION 0.19Kg 72pcs/14.7Kg/0.92CUFT PACKING NOTE %& ( ) * + & , - %& * ) ./ . / 01. 2 . 3 4, 5// /6 /, 3/%& 7&8 Product Liability DisclaimerFor detailed information, please refer to 16W Single Output LED Power Supply PLD-16 series Mechanical Specification Case No.PCD16A Unit:mm A Type:(PLD-16- A) 3 84 15010 UL1430 18AWG V+(RED) V-(BLACK) 7.3 7.3 755 Tcase UL1430 18AWG AC/N(WHITE) 10 AC/L(BLACK) 3 T case: Max. Case Temperature. B Type:(PLD-16- B) 3 84 15010 UL1430 18AWG V+(RED) V-(BLACK) 7.3 7.3 755 Tcase NISPT-1 18AWG AC/N(BLUE) 10 AC/L(BROWN) 3 T case: Max. Case Temperature. Block Diagram fosc : 90KHz(115VAC) 120KHz(230VAC) RECTIFIERS EMI FILTER POWER +V I/P & & SWITCHING -V RECTIFIERS FILTER DETECTION CIRCUIT O.L.P. PWM & PFC CONTROL O.C.P. File Name:PLD-16-SPEC 2021-09-10 2-8.9 2-8.9 2-3.6 2-3.6 15.3 15.3 57 57 20 20 15.3 15.3 1.9 1.9 29.5 29.5